Hersteller: Bryant
Dateigröße: 345.18 kb
Dateiname: ss580j-02.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The qualified installer or agency must use factory--authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing. Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloths for brazing operations and have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and appropriate national electrical codes (in USA, ANSI/NFPA70, National Electrical Code (NEC); in Canada, CSA C22.1) for special requirements. It is important to recognize safety information. This is the safety--alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, CAUTION, and NOTE. These words are used with the safety--alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices, which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. ELECTRICAL HAZARD Failure to follow this caution may result in personal injury or product and property damage. The electrical data contained in this document is only for use with 48TC size 16 units which display a “3” in the 13th position of the 17 digit model number as displayed on the unit’s nameplate. See Fig. 1 for location of the unit’s nameplate. See Fig. 2 for details of the 17 digit model number. ! CAUTION ELECTRICAL SHOCK HAZARD Failure to follow this warning could cause personal injury or death. Before performing service or maintenance operations on unit, always turn off main power switch to unit and install lockout tag. Unit may have more than one power switch. ! WARNING Nameplate Location C11014 Fig. 1 -- Location of Unit Nameplate 580J*16D 3 580JE16D240A3A0AA 5 1 8 2 6 7 D 8 0 3 J 4 E 5 1 6 2 9 4 10 0 11 A 12 3 13 A 14 0 15 A 16 A 17 Model Number Position of Digit C11017 Fig. 2 -- Example of Nameplate with Model Number 580J*16D Table 1 – Unit Wire/Fuse or HACR Breaker Sizing Data UNITNOM. V---Ph--Hz IFM TYPE COMBUSTION FAN MOTOR POWER EXHAUST NO C.O. or UNPWR C.O. FLA FLA NO P.E. w/ P.E. (pwrd fr/ unit) MCA FUSE or HACR BRKR DISC. SIZE MCA FUSE or HACR BRKR DISC. SIZE FLA LRA FLA LRA STD 68.3 80 71 396 72.1 80 76 400 208/230-- 3-- 60 MED 0.48 3.8 70.8 80 74 413 74.6 90 79 417 6D HIGH 77.8/75.8 100/100 82/80 424 81.6/79.6 100/100 87/84 428 STD 34.0 45 35 234 35.8 45 37 236 580J* 1460---3---60 MED 0.25 1.8 35.0 45 37 243 36.8 45 39 245 HIGH 38.2 50 40 248 40.0 50 42 250 STD 26.5 30 28 184 30.3 40 32 188 575---3---60 MED 0.24 3.8 26.5 30 28 184 30.3 40 32 188 HIGH 29.8 35 31 187 33.6 40 36 191 Table 1 — Unit Wire/Fuse or HACR Breaker Sizing Data (cont) 580J*16D UNITNOM. V---Ph--Hz IFM TYPE COMBUSTION FAN MOTOR POWER EXHAUST w/ PWRD C.O. FLA FLA NO P.E. w/ P.E. (pwrd fr/ unit) MCA FUSE or HACR BRKR DISC. SIZE MCA FUSE or HACR BRKR DISC. SIZE FLA LRA FLA LRA STD 73.1 80 77 401 76.9 100 81 405 208/230-- 3-- 60 MED 0.48 3.8 75.6 100 80 418 79.4 100 84 422 6D HIGH 82.6/80.6 100/100 88/85 429 86.4/84.4 100/100 92/90 433 STD 36.2 45 38 236 38.0 50 40 238 580J* 1460---3---60 MED 0.25 1.8 37.2 50 39 245 39.0 50 41 247 HIGH 40.4 50 43 250 42.2 50 45 252 STD 28.2 35 30 186 32.0 40 34 190 575---3---60 MED 0.24 3.8 28.2 35 30 186 32.0 40 34 190 HIGH 31.5 40 33 189 35.3 45 38 193 Legend and Notes for Table 1 LEGEND: BRKR - --- Circuit breaker CO - --- Convenience outlet DISC - --- Disconnect FLA - --- Full load amps IFM - --- Indoor fan motor LRA - ---Locked rotor amps MCA - ---Minimum circuit amps PE ---Power exhaust PWRD CO - ---Powered convenient outlet UNPWR CO - ---Unpowered convenient outlet NOTES: 1. In compliance with NEC requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be fuse or HACR breaker. Canadian units may be fuse or circuit breaker. 2. Unbalanced 3-Phase Supply Voltage Never operate a motor where a phase imbalance in supply voltage is greater than 2%. Use the following formula to determine the percentage of voltage imbalance. max voltage deviation from average voltage % Voltage Imbalance = 100 x average voltage Example: Supply voltage is 230-3-60 AB = 224 v BC = 231 v AC = 226 v (224 + 231 + 226) 681 Average Voltage = = 3 3 = 227 Determine maximum deviation from average voltage. (AB) 227 – 224 = 3 v (BC) 231 – 227 = 4 v (AC) 227 – 226 = 1 v Maximum deviation is 4 v. Determine percent of voltage imbalance. 4 % Voltage Imbalance = 100 x 227 = 1.76% This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%. IMPORTANT: If the supply voltage phase imbalance is more th...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien