Anleitung Zusammenfassung


100.1 Rev. 6/30/65 CLEARANCES FROM COMBUSTIBLES In "large” rooms 6" from caging. & vent hood 1" from sides & top of supply plenum In confined spaces 0" from casing sides, rear & bottom 6" from casing front & type C vent connector 3" from top & sides of uninsulated supply plenum SHIPPING WEIGHT 180 lbs. HEATING RATINGS AND CAPACITIES BURNER a CONTROL ACCESS ACCESS DOOR FILTER AND BLOWER BOTTOM RETURN OPENING - -18j--16#- Rating1 Input2 BTUH 100,000 Output BTUH 80,000 Air Delivery @ 85° Rise CFM 870 Motor—Type L—4 Speed H HP (SH. Pole) Power Supply 1Í5-60-1 Full Load Amps 6.7 Speed & Rotation 1050 CCW* Motor—Type E—4 Speed Уг HP (PSC) 'Power Supply 115-60-1 Full Load Amps 6.4 Speed & Rotation 1075 CCW* Motor—Type B—1 Speed Ы HP (Split Ph.) Power Supply 115-60-1 Full Load Amps 4.1. Speed & Rotation 1725 CW * Motor Pulley Dia. & Bore 2.4-1.6" X Blower Pulley Dia. & Bore 5" X H" Belt Vs " X 34" Motor—Type C—1 Speed И HP (Split Ph.) Power Supply 115-60-1 Full Load Amps 5.0 Speed & Rotation 1725 CW* Motor Pulley Dia. & Bore 2.9-1.9" X V2" Blower Pulley Dia. & Bore 5" X M" Belt Width & Length Vs" X 34" Blower Wheel Dia. & Width 10 X 8 Bore—Direct Drive %" Bore—Belt Drive M" Filter—Fiberglass * * Inlet At Bottom 16" X 25" X 1" External Filter Rack 16" X 25" X 1" Rear Drop Duct 16" X 25" X 1" OPTIONAL REAR DROP DUCT FOR 8ASEMENT APPLICATIONS STANDARD GAS CONTROL OPTIONS Control Type Gas D2 LPG D4 City 1Ratings are for elevations up to 2000 ft.; for higher altitudes, reduce ratings 4% for each 1000 ft. above sea level. 220% reduction in input allowed. COMPONENT INFORMATION 100% shut-off automatic pilot; Bryant diaphragm valve; transformer. Bryant diaphragm valve; Bryant automatic pilot; gas pressure regulator; transformer; pilot gas filter (for manufactured gas only). Special Control Option: 100 % shut-off for natural gas same as D4 except uses thermocouple pilot & pilot relay. CONNECTIONS Gas Supply NPT—Natural ^ —Manufactured“*""' ЛЫ 1 —Profane ^ 1 Electric Supply—B Mo^pr ^p*® $1^ „ 11SS60-B —C Mot|r fc- —E Mot* ] №-*11 —L Moto& d H ' in:i5-6Pi ! Branch Circuit Wire Sizlb ff-AWfSP "■14 Fuse Size \ "'^MPS * . W ^ 1 1 Control Circuit Power Avail. v^"v 1 \j Flue Size \ \ Infchesf . §40^af V—l Duct—Inlet at bottom \ D 5uWlfv \|2}J Inlet ext. filter rack \ ^ Inlet drop duct **D x'WL^* —ТГх 16 % Discharge ‘©'x'W 20 X 16 Уг CONTROL INFORMATION Burners (Steel Slotted Port) 4 Orifice Drill Size Prop. 54 .. Nat. 41 Mfd. 29 D2 Control (Prop.) Regulator Not Included Valve H A641 Escapement Orifice Drill Size 80 Pilot—MH 314A .011 Orifice D4 Control (Nat.) Regulator Comb. Thermae Vi VR-1 Valve A641 Escapement Orifice Drill Size 80 Pilot—732 .016 Orifice D4 Control (Mfd.) Regulator Thermae T11L or Rehrig 'A E15-1 Valve A641 Escapement Orifice Drill Size 80 Pilot— 2 H .024 Orifice ‘Rotation viewed from end opposite shaft **Use multi-velocity filters above 1000 CFM Manual Shut-off Cock and Pilot Cock are standard equipment. Supplied as separate parts except where included as integral part of the combination regulator. AIR FLOW FOR INDICATED AIR TEMPERATURE RISE* TEMP. RISE °F 70 75 80 85 90 95 100 105 AIR FLOW CFM 1060 989 927 870 823 780 741 705 * At Rated Input AIR DELIVERY PERFORMANCE Air Delivery CFM EXTERNAL STATIC PRESSURE AVAILABLE Type L Motor Type E Motor Hi Med Med-Lo Lo Hi Med Med-Lo Lo 700 0.56 0.34 0.91 0.77 0.69 0.30 800 0.41 0.00 0.78 0.64 0.55 0.00 ■ 900 0.23 0.68 0.55 0.40 1000 0.06 0.61 0.45 0.00 1100 0.54 0.00 1200 0.44 1300 0.29 1400 0.08 Air Delivery CFM EXTERNAL STATIC PRESSURE AVAILABLE Type C Motor O-T.O. 1-T.O. .2-T.O. 3-T.O. 4-T.O. 5^T.O. 700 0.85 0.69 0.59 0.51 0.38 0.28 800 0.80 0.69 0.55 0.43 0.30 0.20 900 0.75 0.60 0.49 0.34 0.21 0.09 1000 0.68 0.51 0.38 0.24 0.11 1100 0.59 0.40 0.27 0.13 0.00 1200 0.49 0.28 0.13 0.00 1300 0.13 Drive Range 683-1043 RPM. 72 RPM change per T.O. Air Delivery CFM EXTERNAL STATIC PRESSURE AVAILABLE Type B Motor O-T.O. 1-T.O. 2-T.O. 3-T.O. 4-T.O. 700 0.55 0.45 0.32 0.23 0.13 800 0.49 0.37 0.24 .0.14 0.03 900 0.41 0.28 0.14 0.02 1000 0.31 0.18 0.01 1100 0.20 0.07 1200 0.07 Drive Range 575-863 RPM. 72 RPM change per T.O. Optional External Filter Rack Mounts on Either Side L1NE-T0-LINE SCHEMATIC UNIT WIRING DIAGRAMS Belt Drive (except LPG) Belt Drive (LPG only) Direct Drive (LPG only) PDS 393U. TOO. 1 -2-...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien