Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Bryant, modell 330AAV

Hersteller: Bryant
Dateigröße: 173.98 kb
Dateiname: om04-37.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS: — Do not try to light any appliance. — Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not use this furnace if any part has been under water. Immediately call a qualified service technician to inspect the furnace and to replace any part of the control system and gas control which has been under water. WELCOME TO GENERATION OF COMFORT Congratulations! Your new, high efficiency gas furnace is a sound investment which will reward you and your family with years of warm memories winter after winter. Not only is your new furnace energy efficient, it is also extremely reliable and supplies superior home comfort. Spend just a few minutes with this booklet to learn about the operation of your new furnace and the small amount of maintenance it takes to keep it operating at peak efficiency. Years went into the development of your new furnace. Take a little time now to assure its most efficient operation for years to come. 1 2 MODEL 330AAV Upflow MODEL 331AAV Furnace Downflow/Horizontal Furnace UPFLOW FURNACE 1 11 COMPONENTS 1 2 Relief Box Gas Valve Control Knob or Electric Switch (On/Off) 2 2-Stage Gas Valve 3 4 Manual Reset Flame Rollout Switch (2) 5 12 Gas Burner Flame Sensor Hot Surface Ignitor 13 6 Rating Plate 7 Status LED Light 8 Blower and Blower Motor 9 14 10 Draft Safeguard Tube and Switch 15 Gas Manifold Blower Door Safety Switch Filter Retainer Air Filter 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 DOWNFLOW/HORIZONTAL FURNACE COMPONENTS 1 Manual Reset Auxiliary Limit Switch Blower and Blower Motor 2 Relief Box Gas Valve Control Knob or Electric Switch (On/Off) 2-Stage Gas Valve 3 Gas Burner Rating Plate Status LED Light 4 Blower Door Safety Switch 5 Draft Safeguard Tube and Switch 6 Manual Reset Flame Rollout Switch (2) Gas Manifold Hot Surface Ignitor Flame Sensor IMPORTANT FACTS Your furnace must have adequate airflow for efficient combustion and safe ventilation. Do not enclose it in an airtight room or “seal’’ it behind solid doors. To minimize the possibility of serious personal injury, fire, damage to your furnace, or improper operation, carefully follow these safety rules: • Keep the area around your furnace free of combustible materials, gasoline, and other flammable liquids and vapors. • Do not cover the furnace, store trash or debris near it, or in any way block the flow of fresh air to the unit. 5 • Combustion air must be clean and uncontaminated with chlorine or fluo7 rine. These compounds are present in many products around the home, such as water softener salts, laundry bleaches, detergents, adhesives, paints, varnishes, paint strippers, waxes, and plastics. Make sure the combustion air for your furnace does not contain any of these compounds. During remodeling be sure the combustion air is fresh and uncontaminated. If air with vapors of these compounds is burned in your furnace, the heat exchangers and metal vent system may deteriorate. • A furnace installed in an attic or other insulated space must be kept free and clear of insulating material. Examine the furnace area when installing the furnace or adding more insulation. Some materials may be combustible. NOTE: Do not use this furnace if any part has been under water. Immediately call a qualified service technician to inspect the furnace and to replace any part of the control system, electrical components and any gas control which has been under water. NOTE: The qualified installer or agency must use only factory- authorized replacement parts, kits, and accessories when servicing this product. 8 9 10 11 12 13 14 This furnace contains safety devices which must be manually reset. If the furnace is left unattended for an extended period of time, have it checked periodically for proper operation. This precaution will prevent problems associated with no heat, such as frozen water pipes, etc. See “Before You Request a Service Call’’ section in this manual. SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components.Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. Observe safety precautions in this manual, on tags and labels attached to the furnace, and other safety precautions that may ...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - 331AAV (173.98 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien