Login:
Stimmen - 1, Durchschnittliche Bewertung: 5 ( )

Anleitung Ultimate Products, modell AL

Hersteller: Ultimate Products
Dateigröße: 3.7 mb
Dateiname: CarwashHeaters_Manual.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


TECHNICAL DATA (a) General Information (b) ER-Series heating Models (or GX, CW, AL, SC) (c) Typical Arrangement of Heater 2 2 – 4 2. PACKAGING AND SHIPPING 4 – 5 3. MOUNTING CLEARANCES 5 – 6 4. PRE-ASSEMBLY 6 5. INSTALLATION 7 6. GAS CONNECTION 8 – 9 7. ELECTRICAL CONNECTION 10 – 11 8. VENT REQUIREMENT AND DETAILS (a) Unvented units (b) Vertical Vent (c) Horizontal Vent 12 – 13 9. FRESH AIR DUCTED INTAKE (a) Vertical Thru Roof (b) Horizontal Thru Wall 13 10. INSTALLATION CHECK OUT AND START UP 14 – 15 B. SERVICE AND MAINTENANCE INSTRUCTIONS 1. Servicing Instructions 2. Routing Service 3. Replacement of Components 4. User Instructions 16 – 21 C. Appendix ‘A’ 22-53 D. Appendix ‘B’ 54-56 Note: All reference to standard specifications, codes, regulations, etc., are intended to reflect latest editions included in the ANSI Testing, Construction, Performance and Installation Standards. (ANSI/ NFPA standard 1985) 2319 Laurelbrook Street, Raleigh, NC 27604 · (800) 542-7221 · FAX (919) 834-4526 · -1 WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damager, injury, or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. A. INSTALLATION INSTRUCTIONS A.1 TECHNICAL DATA (a) General Information Model & Heat Input Information all units: Gas Supply Connection: .-inch NPT Male Electrical Supply: 120V, 1 phase, 60Hz Current Rating: 1.2 AMP MAX (Burner-0.3/Fan – 0.9) Ignition: Electronic Program Start-up with Spark Ignition OPTIONS: 1. Modify combustion chamber air intake for fresh air duct. 2. Ultimate Products Black Bulb Thermostat. 3. Control Panel with multi-zone capabilities. (Not A.G.A. Certified) 4. Individual Heater Vent to Exterior. Notes: A. Heater is intended for heating non-residential indoor and outdoor spaces and should only be installed where flammable gases or vapors are not generally present. B. Indoor heaters may be suspended either horizontal or at an angle, or may be wall mounted. Outdoor heaters must be suspended horizontally. SEE SECTION A.3 FOR CLEARANCES. C. Installation shall conform with local building code requirements and with National Fuel code ANSI-Z223.1.A. (Latest Edition) and section 7.8A-3; Z223.1 (Latest Edition). D. The unit shall be electrically grounded in accordance with National Electric Code ANSI/NFPA 70-1987. E. The heater may be installed in aircraft hangars when conformation with ANSI/NFPA 409-1985 for Aircraft Hangars and in automotive garages when conforming with ANSI-NFPA 88A (Latest Edition) for Parking Structures and ANSI/NFPA 88B (Latest Edition) for Repair Garages. Insure that minimum clearance will be maintained to vehicles parked below the heater. 2319 Laurelbrook Street, Raleigh, NC 27604 · (800) 542-7221 · FAX (919) 834-4526 · -2 Pipe Capacities For Propane and Natural Gas Pipe Capacities For Propane in Thousands of BTUs Per Hour For pressure drop of 0.5” W.C., based on low-pressure piping based on 6 oz. per sq. in. pressure. Based on one Cubic Foot of Propane = 2500 BTUs. SIZE PIPE INCHES LENGTH OF STRAIGHT PIPE IN FEET 15 30 45 60 75 90 105 120 150 180 210 240 270 300 450 600 . 105 77.5 65 55 50 45 40 . 425 300 245 212.5 190 172.5 160 150 137.5 125 115 107.5 102.5 95 80 67.5 1 787.5 615 505 440 395 362.5 330 315 282.5 252.5 237.5 220 205 197.5 157.5 137.5 1. 1542.5 1070 882.5 770 677.5 630 582.5 542.5 487.5 440 410 385 362.5 347.5 282.5 237.5 1 . 2425 1700 1402.5 1212.5 1070 977.5 912.5 857.5 772.5 700 645 607.5 575 542.5 440 377.5 2 5040 3490 2835 2520 2205 2047.5 1890 1732.5 1575 1417.5 1322.5 1245 1165 1117.5 897.5 770 3 13545 9607.5 7875 6772.5 5985 5512.5 5197.5 4882.5 4252.5 3937.5 3622.5 3387.5 3232.5 3072.5 2520 2127.5 4 28035 19687.5 16222.5 14017.5 12600 11497.5 10710 9922.5 8820 8032.5 7560 6930 6615 6300 5040 4410 Pipe Capacities For Natural Gas In Thousands of BTUs Per Hour For pressure drop of 0.5” W.C. pressure. Based on one Cubic Foot on Natural Gas = 100 BTUs. SIZE LENGTH OF STRAIGHT PIPE IN FEET PIPE INCHES 10 20 30 40 50 60 70 80 90 100 125 150 175 200 300 400 500 600 700 800 1000 . 170 118 95 80 71 64 60 55 52 49 44 40 37 34 27 23 21 19 . 360 245 198 169 150 135 123 115 108 102 92 83 77 71 57 48 43 39 1 540 440 325 285 250 225 215 195 185 177 155 140 130 120 100 80 70 65 57 48 40 1 . 1125 790 660 570 510 465 440 410 390 375 355 305 280 260 205 180 165 140 125 115 100 1 . 1700 1200 1000 865 780 720 670 620 600 570 510 455 430 400 315 265 240 215 195 180 150 2 3100 2225 1855 1600 1450 1375 1250 1175 1120 1075 970 880 820 760 610 530 470 420 390 365 320 2 . 5040 3525 3000 2600 2350 2175 2025 1890 1810 1745 1570 1420 1315 1225 995 845 740 660 620 570 500 3 9100 6500 5300 4600 4435 3780 3530 3290 3140 3020 2905 2840 2450 2140 1640 1385 1210 1085 930 900 760 3 . 9500 7880 6780 6140 5670 5280 4940 4685 4300 4000 3660 3380 3185 2500 2300 1890 1690 1545 1445 1245 4 9450 8500 7880 7325 68...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - CW (3.7 mb)
elektrische Heizungen - ER (3.7 mb)
elektrische Heizungen - SA (3.7 mb)
elektrische Heizungen - SC (3.7 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien