Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Sierra Products, modell EF-3801B-AL

Hersteller: Sierra Products
Dateigröße: 1.58 mb
Dateiname: 140661C_EF3801-B_Manual.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


GENERAL INFORMATION Installation and repair should be done by a qualified service person. The heater should be inspected before use and atleast annually by a professional service person. More frequent cleaning may be required due to fuel quality, excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the heater be kept clean. The EASYFIRE Pellet heater has been designed and approved for burning wood pellet fuel only. Burning other forms of fuel is not permitted and will void all warranties. This unit has been approved for use with a 3" Type L Pellet Vent System . NEVER use gasoline, gasoline-type lantern fuels, kerosene, charcoal lighter fluid, or similar liquids to start or "freshenup" a fire. Keep all such liquids well away from the heater while it is in use. Ashes must be disposed of in a metal container with a tightfitting lid and placed on a noncombustible floor or ground, well away from all fuels, pending final disposal. NOTE : During the first few burns the high temperature paint and sealant used in manufacture will emit some odorand smoke. Open doors and windows to the outside for proper ventilation during the first burn cycle and curing ofthe paint. This heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 702006. Provide adequate clearances around air openings into thecombustion chamber and adequate accessibility clearance for servicing and proper operation. Never obstruct the frontopening of the heater. The heater may be installed as a free-standing unit mounted on a non-combustible protective floor pad or hearth. Or itmay be mounted into an existing U. L. approved wood stove chimney. Non-combustible floor protection is required andmust be used when placing the heater on any combustible material. The pellet heater must be operated with a power source andwill not operate using natural draft. If there is a power failure the heater will shut down. If the 12 volt back system is installed, the heater will automatically switch to 12 volt power. The EasyFire Pellet Heater has been listed by OMNI-Test Laboratories, Inc. to ASTM, U.L.,and EPA Standards. SAFETY NOTICE . CAUTION: HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. . IF THIS HEATER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. . FAILURE TO COMPLY WITH OWNERS' MANUAL INSTRUCTIONS WILL VOID YOUR WARRANTY! PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET FUELBURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN INSTALLER:PLEASELEAVE THIS MANUAL WITH THE OWNER!! WARNING: THIS HEATER SHOULD NOT BE INSTALLED IN A SLEEPING ROOM. Sierra Products, Inc. 5061 Brooks St., Ste. B Montclair, CA 91763 Listed by OMNI-Test Laboratories, Inc. Report No. 256-S-01-4 2 Figure 1 -Overall Dimensions Figure 2 OUTSIDE COMBUSTION AIR IS MANDATORY IN MOBILE OR MODULAR HOME INSTALLATIONS. CAUTION: DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. VENTING AND INSTALLATION CLEARANCES CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. A LISTED, 4" MINIMUM TYPE "L" PELLET VENT PIPE IS MANDATORY ON ALL INSTALLATIONS. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT, DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. Use only listed 3" minimum Type "L" pellet vent and components for installation. The exhaust vent system must be attached to the unit and to each adjoining section. All joints for connector pipe shall be fastened with at least three screws. If vented horizontally, joints shall be made gas-tight by sealing with high temperature silicon or material specified by vent pipe manufacturer. Failure to use listed pellet vent pipe or install it per manufacturers instructions will void your warranty. INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER Vent Pipes’ inner and outer diameters may vary. Check with vent pipe manufacturer for further details. WARNING: Installation of a Mobile Home Attachment Kit P/N 10412 and outside combustion air is mandatory in mobile or modular home installations although it may also be used in all residential applications. An outside air inlet MUST be provided for combustion and ventilation air. The air inlet must remain unrestricted while unit is in use. Outside air connection is located in the rear of the heater (Figure 2). Use conduit pipe or metal flex pipe and/or fittings to make the air intake hook-up. CAUTION: STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALLS AND CEILING/ROOF MUST BE MAINTAINED. 1. When deciding on the location of your heater and vent pipe, try to minimize the alteration and reframing of structural components of the building. Vent pipe must be installed so that access is provi...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien