Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Listen Technologies, modell Radiator LBB 4511

Hersteller: Listen Technologies
Dateigröße: 133.3 kb
Dateiname: b63aa90a-d0b6-4963-8f8d-d2a67855a256.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The radiator requires a mains power supply. Key Features & Benefits • Covers up to 10,750 square ft. (999 square meters) (one carrier, 4 standard quality channels)* • Power output selection for efficiency and economy • Universal mains power facility allows use worldwide • No fan - cooled by convection - resulting in quieter operation and less moving parts to wear out • LED indicators for radiator status checking • Communication between radiator and transmitter for easy checking by the operator • Automatically switches on when transmitter is switched on and vice versa • Automatic gain control ensures the IRED’s (infra-red emitting diodes) function with maximum efficiency • Automatic cable equalization ensures maximum transmission efficiency with different quality of cables • Automatic cable termination simplifies installation • Temperature protection circuitry automatically switches radiator from full- to half- power if the temperature becomes too high • Brackets for mounting on ceiling and floor stand included, which simplifies installation • Adjustable radiator angle ensures maximum coverage • IRED’s protected by a cover plate, making the units easy to maintain and clean • Attractive and stylish design • Mains cable included * When the amount of channels in use doubles, the footprint is reduced by half Don't miss a single sound. Listen Technologies Corporation 8535 South 700 West, Suite A Sandy, UT 84070-2515 U.S.A. Phone: 1.801.233.8992 or 1.800.330.0891 Fax: 1.801.233.8995 Email: info@ListenTech.com updated 07.19.05 Listen® and the Listen logo are registered trademarks of Listen Technologies Corporation LBB 4511 Radiator 2 1 3 NOTE: 2 5 6 7 8 and 4 use the same LED’s as 1 and Features 1. Two yellow LED’s: one on each radiator panel to indicate that this panel is switched on and is receiving carrier waves from the transmitter 2. Two red LED’s: one on each radiator panel to indicate that this panel is in standby mode 3. Red and yellow LED’s simultaneously illuminated to indicate the radiator panel is malfunctioning 4. Red LED flashing and yellow LED’s to indicate the radiator panel is in temperature protection mode 5. Power reduction switch to reduce the output of the radiator to half-power 6. Two delay compensation switches to compensate for differences in cable lengths between transmitter and radiators 7. Male Euro socket for mains connection 8. HF input and output connectors (2 x BNC) for connection to transmitter and loop-through to other radiators Don't miss a single sound. Listen Technologies Corporation Phone: 1.801.233.8992 or 1.800.330.0891 8535 South 700 West, Suite A Fax: 1.801.233.8995 Sandy, UT 84070-2515 U.S.A. Email: info@ListenTech.com updated 07.19.05 LBB 4511 Radiator Specifications Cabling and System Limits Cable type Maximum number of radiators Maximum cable length 75 ohm RG59 30 per HF output TBD Suspension bracket for direct ceiling mounting Mounting Mounting plates for floor stands with M10 and ."Whitworth thread LBB 3414/00 Wall Mounting Bracket can be used for fixing radiator to wall surfaces Physical Dimensions (H x W x D) Radiator angle without bracket: 7.9 x 19.7 x 6.9 in. (200 x 500 x 17 mm) 0, 15 and 30° for floor-stand mounting 0, 15, 30, 45, 60, 75 and 90° for wall/ceiling mounting Weight without bracket: 15 lbs. (6.8 kg) with bracket: 17 lbs. (7.6 kg) Finish Bronze colored Number of IREDs 260 Total IR output at 68°F (20 °C) 8 Wrms 16 Wpp Electrical and Optical Total optical peak intensity Angle of half intensity 9 W/sr ± 22° Characteristics HF input nominal 1Vpp, minimal 10 mVpp Mains voltage 90 to 260 V, 50 to 60 Hz Power consumption 100 W Power consumption (standby) 8 W System Environmental Conditions Working conditions Fixed/stationary/transportable Temperature range - transport -40 to 158 °F (-40 to + 70 °C) Temperature range - operating 41 to 113 °F (+5 to + 45 °C) Maximum relative humidity < 93% Safety EMC emission EMC immunity EMC approvals ESD Mains harmonics Environmental requirements According to EN 60065, CAN/CSA-E65 (Canada and US) and UL 6500 According to EN 60065, CAN/CSA-E65 (Canada and US) and UL 1419 for LBB 4511/00 and LBB 4512/00 According to harmonized standard EN 55103-1 and FCC rules part 15, complying with the limits for a class A digital devices According to harmonized standard EN 55103-2 Affixed with the CE mark According to harmonized standard EN 55103-2 According to harmonized standard EN 55103-1 Contains no banned substances as specified in UAT-0480/100 (e.g. no cadmium or asbestos) Photographs, CAD drawings, etc. available at Warranty Most Bosch equipment carries a 3 year limited manufacturer's warranty (excluding accessories) to be free from defects in workmanship and material under normal use and conditions. Bosch rechargeable batteries carry a 1 year warranty. All Bosch accessory items carry a 90-day warranty to be free from defects in workmanship and material under normal use and conditions. Warranty does not cover normal...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien