This heater has hot and arcing or sparking parts inside. Do NOT use in areas where gasoline, paint or other flammable liquids are used or stored. 5. This heater is intended to provide temporary, supplemental localized heat only in non-residential locations. The heater is intended for use on the floor only. Do NOT place heater on surface where is could fall or tip over. 6. Heater element operates at very hot temperatures. Do NOT place heater near combustibles and DONOT place combustibles in the radiation path in front of the heater. Keep all combustibles at least five (5) feet from front of heater. 7. Heater is designed and intended for use as illustrated in this instruction sheet only. Do not position or use heater in any other manner. 8. This heater is hot when in use. To avoid burns, do NOT let bare skin touch hot surfaces. Keep combustible materials, such as furniture and papers at least 5 feet from the front of the heater. 9. DO NOT LEAVE HEATER UNATTENDED WHILE IN OPERATION. 10.Always disconnect heater when not in use. 11. Do NOT use outdoors in areas subject to wind. 12.Connect to properly grounded outlets or building ground. 13.This heater has hot surfaces. Do NOT use it in areas where gasoline, paint or flammable liquids are used or stored. 14.Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons. 15.In order to prevent equipment damage, protect with a ground fault device such as Marley Engineered Products WMGF240 for 240V heaters and WMGF480 for 480V heaters. SAVE THESE INSTRUCTIONS WIRING 1. Use heater only at the voltage specified on the nameplate. 2. The heater connection points are located in the gasketed terminal enclosure. To remove cover, remove screw(s) on the cover. Remove the cover to expose wiring connection points. 3. A green ground terminal is provided in the bottom of the enclosure. The ground wire should be connected before other connections are made. 4. Use type "SO" or equal cord. Refer to Table 1 for proper cord gage and number of conductors. ELECRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property damage. Heater must be effectively grounded in accordance with the National Electrical Code, NFPA 70. All electrical wiring must be done by a qualified person in accor- dance with National Electrical Code (NEC) and meet all state and local regulations. a WARNING ! WIRING 1. Use heater only at the voltage specified on the nameplate. 2. The heater connection points are located in the gasketed terminal enclosure. To remove cover, remove screw(s) on the cover. Remove the cover to expose wiring connection points. 3. A green ground terminal is provided in the bottom of the enclosure. The ground wire should be connected before other connections are made. 4. Use type "SO" or equal cord. Refer to Table 1 for proper cord gage and number of conductors. ELECRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property damage. Heater must be effectively grounded in accordance with the National Electrical Code, NFPA 70. All electrical wiring must be done by a qualified person in accor- dance with National Electrical Code (NEC) and meet all state and local regulations. a WARNING ! Table 1 - Hand Carry Portable- L Series OPTIONAL ACCESSORIES Marley Engineered Products L series radiant heaters can be field modified by adding optional kits. Cord Kits Cord kits consist of 25 feet of 90°C cable and a right angle cord fitting which can connect directly to the heater terminal box or disconnect switch (if used). See instruction sheet 5200-2647-### for details Plugs Single and three phase with ground. Available in nonlocking and locking. See Table 1. Ground Fault Kits WMGF240 series kit mounts to wall that de-energizes the heater prior to element failure. See instruction sheet 5200-2652-###. Model Wattage Volts Amps Cord Guage Cord Set Locking Plug Set Non-Locking Plug Set L1511B 1500 120 12.5 See Note See Note See Note Note: This hand carry model includes cord and standard 3-prong gounded plug. L2081B L2021B L2071B L2041B L2061B 2000 208 240 277 480 600 9.6 8.3 7.2 4.2 3.3 14/3 14/3 14/3 14/3 14/3 CS25143 CS25143 CS25143 CS25143 CS25143 LPS25124 LPS25124 LPS25124 LPS25104 LPS25083 NPS25650 NPS25650 N/A N/A N/A L4581B L4521B L4571B L4541B L4561B 4500 208 240 277 480 600 21.6 18.8 15.9 9.4 7.5 12/3 12/3 14/3 14/3 14/3 CS25123 CS25123 CS25143 CS25143 CS25143 LPS25103 LPS25124 LPS25124 LPS25104 LPS25083 NPS25650 NPS25650 N/A N/A N/A 2 MAINTENANCE The heater requires no special maintenance other than occasional cleaning to prevent excess accumulation of dust and lint on surfaces. It is important for the reflectors to be kept clean to obtain the maximum radiant output. If used as a movable unit, the cart and cord should be checked periodically to make sure th...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - WMGF240 (248.09 kb)