Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.7 ( )

Anleitung Dimplex, modell OFRC25TI

Hersteller: Dimplex
Dateigröße: 643.55 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


If the mains lead is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Unplug the heater when not required for long periods. Momentary contact with any part of the heater should not cause injury. However aged, infirm persons or young children should not be left unsupervised in the vicinity of the heater. Please Note – We recommend that you open a window to ventilate the room when using the heater for the first time. THE HEATER CARRIES THE WARNING SYMBOL INDICATING THAT IT MUST NOT BE COVERED. General The radiator is designed for operation on an AC electricity supply, and is suitable for use in domestic dwellings and similar indoor locations. Always ensure that the appliance is stood on a firm, level base near to, but not directly beneath, a suitable fixed socket outlet. The radiator is fitted with castors and a handle for ease of movement. Selector switches provide a choice of heat output and an adjustable thermostat enables the room temperature to be controlled accordingly. It is supplied with a cord and plug ready for use. The supply cord should be uncoiled before use (see ‘Storage’). DO NOT pull the radiator along by the mains lead. Important -The radiator must only be operated with the wheels and castors fitted and in the upright position as shown in Fig. 1. Warning – The heater complies with stringent safety standards but to ensure efficient operation SURFACES OF THE HEATER WILL BECOME HOT AND CONTACT WITH THESE AREAS SHOULD BE AVOIDED, particularly between the fins on the top and sides. The control panel area is designed to be at a far lower temperature to allow the safe operation of the controls at any time. Electrical WARNING – THIS APPLIANCE MUST BE EARTHED If the socket outlets in your home are not of the 13 amp BS1363 type they will not accept the plug connected to this heater, therefore cut off the plug. When cut off this plug can constitute a shock hazard if inserted into a socket outlet. It must therefore be disposed of safely. Before wiring the appropriate plug please note that the wires in this mains lead are coloured in accordance with the following code: GREEN/YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE Connect the Green/Yellow wire to the terminal marked E or the earth symbol or coloured Green or Green/Yellow. Connect the Brown wire to the terminal marked L or coloured Red. Connect the Blue wire to the terminal marked N or coloured Black. DO NOT connect the Brown (Live) or the Blue (Neutral) wires to the Earth terminal of your 13 amp plug. If the terminals of the plug are unmarked or you are in any doubt, consult a qualified electrician. Fitting the castors Remove the carton containing the castor assemblies from the packing. Fit the castors to the stub axles by applying hand pressure until each castor clicks into position - see Fig. 3. Note that the castors are designed to be a tight fit on the axles but will rotate in use. The castors can only be fitted between the outer fins (as shown in Fig. 2). Turn the radiator upside down on a carpet or other soft surface to avoid damage WARNING : THE RADIATOR IS HEAVY – ENSURE THAT IT IS SUPPORTED TO PREVENT IT FROM TOPPLING. Ask a second person to help with this if necessary. Position castor bracket (see Fig. 3) onto the threaded pins on the control panel. Place the winged nut ‘C’ on the thread and tighten it securely. Repeat the process for castor bracket ‘B’ onto the last fin. Note: The 5 fin column radiator models - OFRC10 & OFRC10TI use curved castor brackets and must be fitted as shown in Fig. 2. Lift the radiator clear of the floor, then turn it back upright and stand it on its castors as shown in Fig. 1. It is now ready for use. Positioning the Heater Select the position for the radiator ensuring there is clearance from any furniture and fittings of at least 300mm above the heater and 150mm each side. The radiator should only be operated on a flat stable surface. Operation IMPORTANT – Objects or clothing must not be placed on this heater. Before using the heater ensure that all warnings and instructions have been read carefully. To bring the heater into use plug it in. Neon indicating lights located at the controls area will glow when the appliance is plugged into the mains. Controls Thermostat (see Fig. 4) The Thermostat (see Fig. 4) controls the heat output according to the room temperature. This ensures that the heater will not produce heat unnecessarily when the room is warm. To set the temperature you require, turn the thermostat knob clockwise until the required setting is reached. Alternat...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - OFRC25 (643.55 kb)
elektrische Heizungen - OFRC20TI (643.55 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien