|
Anleitung Zusammenfassung
Engineered for years of efficient, trouble free service Featuring 20 gauge aluminized combustion chambers, warranted for 10 years. Single Wall Furnace models may be equipped with a Rear Register Kit and Grille (40542) allowing warm air to circulate into the adjoining room. Adjustable vent controls air flow. Resettable Blocked Flue Safety Device automatically shuts the unit off in the event of flue blockage or incorrect vent installation. Continuous Seam-Welded Combustion Chamber constructed of heavy gauge aluminized steel, maximizes heat transfer. Warranted for ten (10) years. Free Standing Kit (FSK) allows single wall furnaces to be surface mounted. Eliminates cutting holes in wall — ideal for masonry wall installation. For use with ceilings up to 8'6" tall; adds 4-3/4" to unit depth. (vent pipe not included). Weight: 16 lbs. SPECIFICATIONS Fan accessory kit (WFF81) available for installation on top of furnace to increase circulation. Adds only 101/2” to height of casing. Fits flush against wall — not recessed. Operates at 50 CFM on 115V. ROUGH IN Optional Night Setback Thermostat (XL 110 / XL411) provides economic as well as convenient operation. Easy installation method reduces installation time to minutes . . . only one man needed. New positive fastening tabs hold grille in place . . . makes installation a snap! ROUGH-IN DIMENSIONS REAR REGISTER OUTLET LOCATION 141/4" MIN. 141/2" MAX. 653/4" 453/4" 125/8" 81/4" PLASTER PLATE REAR REGISTER FRAME OPENING FOR REAR REGISTER MODEL OPENING 7/8" FROM EACH STUD NAIL TO STUDS PLASTER STUD PLASTER4" 4" Model Type Type BTU/Hr. Vent Gas Finished Shipping Rear Register Kit Fan Kit Number Control Gas Input Size Inlet Dimensions Weight Model Weight Model Weight W251 Bulb Nat. 25,000 4" 1/2" 161/2" W . 68" H . 61/2" D 90 lbs. 40542 5 lbs. WFF81 10 lbs. W255 M. Volt Nat. 25,000 4" 1/2" 161/2" W . 68" H . 61/2" D 90 lbs. 40542 5 lbs. WFF81 10 lbs. W252 Bulb L.P. 25,000 4" 1/2" 161/2" W . 68" H . 61/2" D 90 lbs. 40542 5 lbs. WFF81 10 lbs. W256 M. Volt L.P. 25,000 4" 1/2" 161/2" W . 68" H . 61/2" D 90 lbs. 40542 5 lbs. WFF81 10 lbs. W351 Bulb Nat. 35,000 4" 1/2" 161/2" W . 68" H . 61/2" D 90 lbs. 40542 5 lbs. WFF81 10 lbs. W355 M. Volt Nat. 35,000 4" 1/2" 161/2" W . 68" H . 61/2" D 90 lbs. 40542 5 lbs. WFF81 10 lbs. W352 Bulb L.P. 35,000 4" 1/2" 161/2" W . 68" H . 61/2" D 90 lbs. 40542 5 lbs. WFF81 10 lbs. W356 M. Volt L.P. 35,000 4" 1/2" 161/2" W . 68" H . 61/2" D 90 lbs. 40542 5 lbs. WFF81 10 lbs. W501 Bulb Nat. 50,000 4" 1/2" 161/2" W . 68" H . 61/2" D 134 lbs. N/A N/A WFF81 10 lbs. W505 M. Volt Nat. 50,000 4" 1/2" 161/2" W . 68" H . 61/2" D 134 lbs. N/A N/A WFF81 10 lbs. W502 Bulb L.P. 50,000 4" 1/2" 161/2" W . 68" H . 61/2" D 134 lbs. N/A N/A WFF81 10 lbs. W506 M. Volt L.P. 50,000 4" 1/2" 161/2" W . 68" H . 61/2" D 134 lbs. N/A N/A WFF81 10 lbs. SINGLE WALL DUAL WALL One or two fan kits may be used on dual-wall furnace. Form No. GWF 15M 10/05 ...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - 000 BTU (217.67 kb)
elektrische Heizungen - 000 TO 50 (217.67 kb)