Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung Dyna-Glo, modell RMC-KFA210T

Hersteller: Dyna-Glo
Dateigröße: 1.35 mb
Dateiname: 2d7e44bf-b990-4929-b265-e9a845ec45b8.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


- Remove ignitor wire from spark plug. - Remove spark plug from bracket-spark using medium phillips screwdriver. - Clean and regap spark plug electrodes to 3.5mm gap.(0.138") - ReInstall spark plug in bracket-spark. - Attach ignitor wire to spark plug. - Reinstall fan and upper shell. G.) PHOTOCELL CLEAN PHOTOCELL ANNUALLY OR AS NEEDED. (For RMC-KFA 45T/65T/120T/170T Models Only) - Remove upper shell (See page 9). - Remove fan (See page 10). - Remove photocell from it’s mounting. Clean photocell lens with cotton swab. TO REPLACE: Remove side cover near on/off switch. - Disconnect wires from circuit board and remove photocell. - Install new photocell and attach wires to circuit board. - Replace fan and upper shell. Figure 16. Figure 17. Side cover circuit board Photocell wires Photocell Install Photocell 1)Incorrect 2)Correct Photocell lens (For RMC-KFA 210T Model Only) - Remove upper shell (See page 9). - Remove fan (See page 10). - Remove photocell from it’s mounting. Clean photocell lens with cotton swab. TO REPLACE : Remove side cover opposite on/off switch. - Disconnect wires from circuit board and remove photocell. - Install new photocell and attach wires to circuit board. - Replace fan and upper shell. Figure 18. Photocell Install Photocell 1)Incorrect 2)Correct Photocell lens circuit board Side cover Photocell wires Bracket Burner Bracket Spark Spark Plug Gap Ignitor wire 13 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! H.) FUEL FILTER CLEAN OR REPLACE TWICE A HEATING SEASON OR AS NEEDED. (For RMC-KFA 45T/65T/120T/170T Models Only) - Remove side cover screws using medium phillips screwdriver. - Remove side cover. - Pull fuel line off fuel filter neck. - Turn fuel filter 90.to counter clockwise and pull to remove(RMC-KFA45T/65T Models). - Turn fuel filter 90.to clockwise and pull to remove(RMC-KFA120T/170T Models). - Wash fuel filter with clean fuel and replace in tank. - Attach fuel line to fuel filter neck. - Reinstall side cover. Figure 20. (For RMC-KFA 210T Model Only) - Remove side cover screws using medium phillips screwdriver. - Remove side cover. - Pull fuel line (attached valve elbow) off fuel filter neck. - Fuel filter 90.turn to clockwise and pull to remove. - Wash fuel filter with clean fuel and replace in tank. - Attach fuel line to fuel filter neck. - Reinstall side cover. Fuel Filter Fuel Line Side Cover Fuel Filter Figure19. Side Cover Fuel Line NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! I) FUEL VALVE ( For RMC-KFA210T Model only) -Remove side cover screws using medium phillips screwdriver (See page 13). -Remove upper shell (See page 9). -Remove fan (See page 10). -Pull fuel line (lower and upper) off the fuel valve fittings (See figure 21). -Disconnet red and orange wires from valve connector (See figure 21). -Remove 2 screws holding fuel valve and bracket to lower shell Using medium phillips screw driver (See figure 21). -Remove 2 screws holding fuel valve to Bracket using medium phillps screw driver.(See figure 21). -Attach new fuel valve to bracket with 2 screws. -Install new fuel valve and bracket on lower shell with 2 screws. -Connect red and orange wires (polarity not important) to valve connector (See figue 21). -Connect upper and lower fuel lines to fuel valve (See figure 21). -Replace fan, upper shell, side cover. Adaptor Nozzle Fuel Line Hose Upper Screw Screw Bracket Valve Low shell Valve Fittings Valve Connector Electrical Wire Fuel Line Hose Lower Figure 21. 14 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! I.) PUMP PRESSURE ADJUSTMENT -Remove pressure gauge plug from end filter cover. -Install accessory pressure gauge. -Start heater (See Operation, page 8) Allow motor to reach full speed -Adjust pressure (Using a flat blade screwdriver) Turn relief valve to right to increase pressure. Turn relief valve to left to decrease pressure. Set pump pressure below correct for pressure for each model. -Stop heater (See Operation, page 9) - Remove pressure gauge. Replace pressure gauge plug in end filter cover. MODEL PUMP PRESSURE RMC-KFA45T 2.8 psi RMC-KFA65T 3.5 psi RMC-KFA120T 4.5 psi RMC-KFA170T 6.5 psi RMC-KFA210T 8.5 psi Pressure Gauge Plug Relief Valve Pressure Gauge NOTE: USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of alternate or third party components will void any warranty and may cause unsafe operation condition. 15 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! 10. TROUBLE SHOOTING GUIDE TROUBLE POSSIBLE CAUSE CORRECTIVE ACTION Heater ignites but MAIN PCB assembly shuts heater off after a short period of time. (Lamp is flickering) 1. Wrong pump pressure 2. Dirty Air Output, Air Intake and Lint Filter 3. Dirty Fuel Filter 4. Dirt in Nozzle 5. Dirty Photocell Lens 6. Photocell Assembly not properly installed. (Not seeing the flame) 7. Bad electrical connection between photocell and MAIN PCB assembly 8. Defective photocell 9. Defective fuel valve. 1. See Pump Pressure Adjustment, page 15. 2. See Air Output, Air intake and Lint Filters, page 9. 3. See F...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - Dyna-Glo RMC-KFA45T, RMC-KFA65T, RMC-KFA120T, RMC-KFA170T, RMC-KFA210T (1.35 mb)
elektrische Heizungen - RMC-KFA45T (1.35 mb)
elektrische Heizungen - RMC-KFA65T (1.35 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien