Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Honda Automobiles, modell WT20X, WT30X, WT40X

Hersteller: Honda Automobiles
Dateigröße: 1.41 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Tampering and Altering Tampering with or altering the emission control system may increase emissions beyond the legal limit. Among those acts that constitute tampering are: l Removal or alteration of any part of the intake, fuel, or exhaust systems. l Altering or defeating the governor linkage or speed-adjusting mechanism to cause the engine to operate outside its design parameters. L TECHNICAL & CONSUMER INFORMATION Problems That May Affect Emissions If you are aware of any of the following symptoms, have your engine inspected and repaired by your servicing dealer. l• Hard starting or stalling after starting. l Rough idle. l• Misfiring or backfiring under load. l Afterburning (backfiring). l• Black exhaust smoke or high fuel consumption. Replacement Parts The emission control systems on your Honda engine were designed, built, and certified to conform with EPA and California emission regulations. We recommend the use of genuine Honda parts whenever you have maintenance done. These original-design replacement parts are manufactured to the same standards as the original parts, so you can be confident of their performance. The use of replacement parts that are ‘not of the original design and quality may impair the effectiveness of your emission control system. A manufacturer of an aftermarket part assumes the responsibility that the part will not adversely affect emission performance. The manufacturer or rebuilder of the part must certify that use of the part will not result in a failure of the engine to comply with emission regulations. Maintenance Follow the maintenance schedule on page 26 . Remember that this schedule is based on the assumption that your machine will be used for its designed purpose. Sustained high-load or high-temperature operation, or use in unusually wet or dusty conditions, will require more frequent service. TECHNICAL & CONSUMER INFORMATION Air Index An Air Index Information hang tag/label was applied to this engine in accordance with the requirements of the California Air Resources Board. The bar graph is intended to provide you, our customer, the ability to compare the emissions performance of available engines. The lower the Air Index, the less pollution. The durability description is intended to provide you with information relating to the engine’s emission durability period. The descriptive term indicates the useful-life period for the engine’s emission control system. See your Emission Control Warranty for additional information. Descriptive Term Applicable to Emissions Durability Period Moderate 50 hours (0 - 65 cc) 125 hours (greater than 65 cc) Intermediate 125 hours (0 - 65 cc) 250 hours (greater than 65 cc) Extended 300 hours (0 - 65 cc) 500 hours (greater than 65 cc) , The Air Index Information hang tag must remain on the pump until it is sold. Remove the hang tag before operating the pump. / TECHNICAL & CONSUMER INFORMATION Specifications WTPOX Dimensions and weight Length 24.4 in (620 mm) Width 17.1 in (435 mm) Height 15.9 in (405 mm) Dry weight 84 Ibs (38 kg) Engine design and performance 1 Model 1 GXIGOKI Engine type 4-stroke, overhead valve, single cylinder Displacement 9.9 cu-in (163 cm3) [bore X stroke] [2.7 X 1.8 in (68 X 45 mm)] Maximum output 5.5 PS (4.0 kW) at 4,000 rpm Maximum torque 8.0 Ibf.ft (11 N.m, 1.1 kgf.m) at 2,500 rpm Cooling system Forced air Ignition system Transistorized magneto PTO shaft rotation Counterclockwise Tuneup 1 Spark plug gap 1 0.028-0.031 in 1 See page 35. (0.70-0.80 mm) Idle speed 1,400 %g rpm See page 37. Valve clearance Intake: 0.15 f 0.02 mm See shop (cold) Exhaust: 0.20 + 0.02 mm manual.. Other specifications No other adjustments needed. TECHNICAL & CONSUMER INFORMATION WTZOX (continued) ‘ump Suction port diameter 2.0 in (50 mm) Discharge port diameter 2.0 in (50 mm) Total head (maximum) 85.3 ft (26 m) Suction head (maximum) 26.2 ft (8 m) Discharge capacity (maximum) 171.7 US gal (650 !2, 143.0 Imp gal) per minute Self-priming time 50 seconds at 16.4 ft (5 m) Continuous running time Approximately 2-l/2 hours (actual time varies with pump load) Pump performance curve As total head increases, discharge capacity decreases. The following graph shows the relationship between pump discharge capacity and total head, while pumping clear water at sea level. 9a- 0 200 400 600 800 1000 1200 1400 (Wmin) 52.8 105.7 158.5 211.4 264.2 317.0 369.9 (US gal/min) DISCHARGE CAPACITY TECHNICAL & CONSUMER IljJFORMATION ingine design and performance Model 1 GX240Kl Engine type 1 4-stroke, overhead valve, single cylinder Displacement 1 14.8 cu-in (242 cm3) [bore X stroke] 12.9 X 2.3 in (73 X 58 mm)] Maximum output 8 PS (5.9 kW) at 3,600 rpm Maximum torque 12.3 Ibfaft (16.7 N.m, 1.7 kgf.m) at 2,500 rpm Coolina svstem I Forced air Ignition system 1 Transistorized magneto PTO shaft rotation 1 Counterclockwise Tuneup Spark plug gap 0.028 -0.031 in See page 35. (0.70-0.80 mm) Idle speed 1,400 f 150 rpm See page 37. Valve clearance Intake: 0.15 31 0.02 mm See sh...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - and WT40X (1.41 mb)
elektrische Heizungen - WT30X (1.41 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien