Login:
Stimmen - 5, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Haier, modell BRF1- 120

Hersteller: Haier
Dateigröße: 767.74 kb
Dateiname: e53931fa-8533-4016-b902-4f8aec46343e.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Confirming of the setting of each parameter can be done by pressing the setting key or by not pressing the setting key about 6 seconds.Then the system will automatically confirm and automatically enter the next parameter setting, until the system finally withdraws from the set conditions and returns to the conditions of the previous clock. The set order of parameter in specific modes is as follows: Solar energy heating mode: Indicating clock condition---to set heating temperature in fixing temperature-- indicating clock condition. For example: temperature difference value setting of water pump running: to press the setting key to enter the setting condition of temperature difference of water pump running. The indication board indicates the present set value (the first place on the left of the clock number tube indicates L, and the following two places indicate the tacitly approved set value, which is 10 ). To press V to select between 10 and 6 . For the indication interface, see Fig.8. Simultaneous heating mode: Indication clock condition--to set heating temperature in fixed temperatureindication clock condition Preset heating mode: Indicating clock condition--to set hour of the first preset heating time in fixing time --to set minute of the first preset heating time in fixing time - -to set temperature of preset heating in fixing temperature -- to set hour of the second preset heating time in fixing time -- to set minute of the second preset heating time in fixing time ---to set temperature of the second preset heating in fixing temperature ---indicating clock condition. For example: to set the temperature of the first preset heating, and for the indication interface,see Fig. 9. Intellectual heating mode: Indicating clock condition---to set temperature of heating in fixing temperature column--- indicating clock condition. Note:after the set (tacitly approved) information is confirmed, the machine will automatically store it and customers can select the present working mode according to their practical necessity. Only when the present working mode is selected, can the corresponding set content be carried out. Exhaust valve Tee joint Metal pipe: ( copper or corrugation pipe) Pump Safety valve Water-storing tank Outdoors Indoors Metal or PPR pipe Vacuum tube Collector Line-controlling equipment Single direction valve Water-entering opening Water-exiting pipe Water-exiting opening Cold water inlet Hot water outlet Fig.1 BRF1-120/150W structure sketch map Hot water outlet Cold water inlet Pump Safety valve Water-storing tank Outdoors Indoors Metal or PPR pipe Flat collecter Line-controlling equipment Single direction valve Water-exiting opening Metal pipe: ( copper or corrugation pipe) Tee joint Water-exiting pipe Fig.2 PJF1-120/150W structure sketch map Exhaust valve 13 2 Technical parameter Packing list Use method Technical parameter Packing list Use method Technical parameter Model Volume Water-proof Grade Rated internal Pressure Size BRF1-120W PJF1-120W 120L Drip-proof 0.75MPa 492 530 1160(mm) BRF1-150W PJF1-150W 150L Drip-proof 0.75MPa 492 530 1380(mm) Model Rated voltage Frequency Assistant powerLighting area BRF1-120W 220V~ 50Hz 2000W 2.51m2 BRF1-150W 220V~ 50Hz 2000W 3.02m2 PJF1-120W 220V~ 50Hz 2000W 3.00m2 PJF1-150W 220V~ 50Hz 2000W 4.00m2 Note: the above parameter errors ( except power value) of the lighting area are 3%, volume errors are 3%, and the allowed error scope of other sizes is 10%. Packing list Name of components Packing method Packing container o f w a t e r t a n k BRF1-120/150W PJF1-120/150W Water-storing tank Safety valve Large expanding bolt Users manual Exhaust valve Model Tee joint Pump water pump joint 1 water pump joint 2 Screw nut Rubber spacer Opposite wires S1/2F-3/4M Packing of pump 3/4 fiber spacer Collector equipment Single-direction valve 1 1 4 1 1 1 1 1 2 1 1Packing of collector Note: accessories of BRF1-120/150W and PJF1-120/150W products are suitable only for oblique installment. For flat installment, prop stand of different angles should be made according to requirements, which is not included in the packing accessories. ` 1 1 1 Board hanging on door Top cover for in-wall box Bottom cover for in-wall box 4 4 1 1 Fig.7 and at this time, only power supply key is effective and other keys are ineffective. The interface only displays water temperature of water-storing tank and the temperature of water exiting of collector equipment. However, when the system is turned off, the solar heating and malfunction alarm protection are all working and only if the conditions for the running of the water pump are Satisfied, water pump will run at full speed. When malfunction alarm appears, it will display malfunction code. B.Selection of working mode: the system provides four working modes, and customers can select any mode as the present working mode. When the system is turned on, press the mode key, and the system will circularly exchange in order of solar energy heating, simultaneous ...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - BRF1- 150W (767.74 kb)
elektrische Heizungen - PJF1- 120 (767.74 kb)
elektrische Heizungen - PJF1- 150W (767.74 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien