Anleitung Zusammenfassung
WARNING: Hazard of Fire. Keep electrical cords, drapes, rugs and other furnishings away from the heater. The normal operating temperatures of cabinet convectors are relatively high. Proper operation requires free circulation of room air through the heating element. Installation Wall 1. Unpack the heater from the carton and remove the front panel. Note: The front panel screws are recessed at the bottom of the top front panel at each end of the heater. (Figure 2) Remove top front panel by pulling down to disengage from top of heater. To remove the bottom front panel, remove screws as shown in Figure 3. Pull bottom front panel by pulling upward to disengage from bottom of heater. 2. Remove the desired terminal box covers and wire supply knockouts from the terminal box area. 3. Determine the correct mounting height, and scribe or snap a level line on the wall to maintain each heater back plate in a horizontal alignment, when mounting. 4. Mount the back plate to the wall using suitable fasteners (provided by customer) using the scribed line on the wall to keep the heater level. TIP: Should the wall surface be uneven, secure the heater back panel to the high spots. This will avoid a distorted appearance. 5. Proceed to the wiring instructions. Recessed Wall Note: The use of a ALTB Trim kit is strongly recommended when recessing the heater. A recess opening dimension of 20-1/2” high and the length of the heater is required to install this heater. The heater may be recessed up to a depth of 5-5/8”. Top PanelScrews BottomPanelScrewsFigure 2 Figure3 INSTALLATION (Recessed Wall) 1. Unpack the heater from the carton and remove the front panel. Note: The front panel screws are recessed at the bottom of the front panel at each end of the heater. 2. Remove the desired terminal box covers and wire supply knockouts from the terminal box area. 3. Use trim frame as a template to drill holes into the top, bottom and sides of the heater using a 1/8” diameter drill bit. 4. Secure the trim frame using the #8 screws provided with the trim kit. TIP: The bottom trim may be omitted if the heater is to be installed at floor level. 5. Prepare the wall recess opening to accept the heater. TIP: Leave approximately 1/2” clearance to insert the heater cabinet. 6. Secure the back plate into the recess opening using suitable fasteners (Provided by customer). 7. Proceed to the wiring instructions. WIRING Note: All wiring should be done in accordance with local codes and the National Electrical Code by a qualified person. 1. Run branch circuit wiring of proper voltage and wire size to the location of the terminal box of the heater. TIP: Supply wire entry is commonly made into one heater. Through wiring (factory furnished) can be used for connection to adjacent heaters. Recommended minimum supply wire sizes are listed in the table below: Maximum Watts Per Circuit Using 75°C. Wire Rough In Wire Size 120V 208V 240V 277V 347V 480V 600V Copper Wire 14 1440 2496 2880 3324 4164 12 1920 3328...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - CAF-20220 (133.78 kb)
elektrische Heizungen - CAF-20215 (133.78 kb)
elektrische Heizungen - CAF-20330 (133.78 kb)
elektrische Heizungen - CAF-20440 (133.78 kb)