|
Anleitung Zusammenfassung
Neglecting them can cause a risk of fire. Only one electrical heater may be installed in the sauna room. Figure5.Min.distancestocombustiblematerials Table1.InstallationdetailsofaJMheater.Seefig.4anditem2.3."Heateroutput" 8 3.2. Fastening the Heater on a Wall 1. Fasten the wall-mounting rack on the wall byusing the screws which come with the rack. Observe the minimum safety distances given in table 1 and fig. 5. The fastening of the mounting rack isshown in figure 6. NOTE! There should be a support, e.g. a board, behind the panel, so that the fastening screws can be screwed into a thicker wooden material than the panel. If there are no boards behind the panel, the boards can also be fastened on the panel. See figure 4. 2. Lift the heater onto the rack on the wall so that the connecting box switches are easily accessible. 3. The steam distributor / rock guard must always be fastened on the wall side of the heater. To turn the distributor / guard, loosen the fastening screw and then turn it. See figure 9. 3.3. Installation capillary tubing and bulb Before hooking up electrical wires to junction box of heater, remove capillary tubing and bulb from junction box and bring up wall to left or right side of heater. Cover tubing with wooden molding provided, coil up excess tubing, and place under heater close to floor. Be sure to cover thermostat bulb with protective metal cover by threading bulb through holes in cover, and fasten bulb cover to wall with screws provided. Also, take care when nailing protective wood strips over capillary tubing, so that nails do not puncture tubing. If punctured, entire thermostat must be replaced. See figure 7. 3.4. Safety Railing If a safety railing is built around the heater, the minimum distances given in fig. 8 must be observed. Figure 6. Location of the mounting rack of the heater Figure 7. Installation of the thermostat sensor Figure 8. Safety railing of the heater Figure 9. Connections and parts of the heater 9 3.5. Electrical Connections The heater may only be connected to the electrical network in accordance with the current regulations by an authorised, professional electrician. Refer to the chart in table 2 to determine the wire size and circuit protection required. The complete sauna system should be properly grounded as per NEC or as required by local codes. A grounding terminal is provided in the wiring compartment of each heater, complate the wiring according to the appropriate wiring figure 10. See table 1 for required clearances. Any wiring within internal Sauna walls must be rated for 90°C (194°F) and copper wire must be used. Run wire through seal tight flex conduit from wall to heater and connect to junction box. Note! If connection to heater will be made at a later time, bring flex into Sauna room 4.6" (100.150 mm) from floor, and leave 3’ (900 mm) of flex for hookup (can be cut to right lenght later). Further instructions concerning exceptional ...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - ELECTRIC SAUNA HEATER JM-20 (841.43 kb)
elektrische Heizungen - ELECTRIC SAUNA HEATER JM-17 (841.43 kb)
elektrische Heizungen - ELECTRIC SAUNA HEATER JM-17 (841.43 kb)
elektrische Heizungen - ELECTRIC SAUNA HEATER JM-17 (841.43 kb)