|
Anleitung Zusammenfassung
ID MODELS LO COMP Single Stage Compressor (OUT) O Reversing Valve Energized in Cool HI COMP Second Stage Compressor (OUT) TWO STAGE AIR CONDITIONER C 24 – Volt Common R 24 – Volt Hot Y1 First Stage Compressor Y2 Second Stage Compressor External Humidistat (Optional) Open on Humidity Rise 2 Part Number: S1-2HU16700124 2 TP(8,L)C YP(8,L)C CP(8,L)C LP(8,L)C FIGURE 21: Thermostat Chart - Two Stage Air Conditioner with Single Stage Thermostat – Variable Speed or PSC Modulating Furnace Johnson Controls Unitary Products 368262-UIM-B-1008 C 24 – Volt Common R 24 – Volt Hot Y1 First Stage Compressor O Reversing Valve Energized in Cool L Malfunction Light G Fan *DP32H70124THERMOSTAT W1 Second Stage Aux. Heat E Emergency Heat W2 Third Stage Heat N/A *BP21H50124*BN21H00124*DP21H40124*DN21H00124THERMOSTAT N/A *DN22U00124THERMOSTAT Part Numbers: SAP = Legacy 67297 = 031-01975 O Reversing Valve Energized in Cool C 24 – Volt Common R 24 – Volt Hot W1/66(out) Heat Y Compressor DEMAND DEFROST CONTROL X/L Malfunction Light W Auxiliary Heat SINGLE STAGE HEAT PUMP 1 1 Part Number: S1-2HU16700124 3 Y2 Second Stage Compressor Step 9 of Thermostat Installer / Configuration Menu must be set to Pump OFF Step 1 of Thermostat Installer / Configuration Menu must be set to Heat Pump 1 E*B* E*ZD E*R* OD MODELS *HGD HP* *RHS C 24 – Volt Common R 24 – Volt Hot Y1 Single Stage Compressor MODULATING FURNACE CONTROL G Fan MODULATING FURNACE Y/Y2 Second or Full Stage Compressor DHUM Dehumidification- Open on Humidity Rise W Modulating Heat Part Numbers: SAP = Legacy 2 2 Move HUMIDISTAT jumper to “YES” if humidistat is to be used. LO COMP Single Stage Compressor (OUT) O Reversing Valve Energized in Cool HI COMP Second Stage Compressor (OUT) External Humidistat (Optional) Open on Humidity Rise 3 ID MODELS TP(8,L)C YP(8,L)C CP(8,L)C LP(8,L)C FIGURE 22: Thermostat Chart - Single Stage Heat Pump – Variable Speed or PSC Modulating Furnace Johnson Controls Unitary Products 368262-UIM-B-1008 C 24 – Volt Common R 24 – Volt Hot Y1 First Stage Compressor O Reversing Valve Energized in Cool L Malfunction Light G Fan *DP32H70124THERMOSTAT W1 Second Stage Aux. Heat E Emergency Heat W2 Third Stage Heat Step 1 of Thermostat Installer / Configuration Menu must be set to Heat Pump 1 C 24 – Volt Common R 24 – Volt Hot Y1 First Stage Compressor O Reversing Valve Energized in Cool L Malfunction Light Y2 Second Stage Compressor G Fan *BP21H50124*BN21H00124*DP21H40124*DN21H00124THERMOSTAT E Emergency Heat W2 Second Stage Heat B/O Switch on Thermostat must be in the O position C 24 – Volt Common Y1 First Stage Compressor O/B Reversing Valve L Malfunction Light Y2 Second Stage Compressor G Fan *DN22U00124THERMOSTAT E Emergency Heat AUX Auxiliary Heat R 24 – Volt Hot (Heat XFMR) R 24 – Volt Hot (Cool XFMR) O Reversing Valve Energized in Cool C 24 – Volt Common R 24 – Volt Hot W1 OUT First Stage Heat W2 OUT Second Stage Heat Y2 OUT Second Stage Compressor Y1 Single Stage Compressor X/L Malfunction Light Y2 Second Stage Compressor W Auxiliary Heat BS Bonnet Sensor BSG Bonnet Sensor YORKGUARD VI CONTROL SINGLE STAGE HEAT PUMP Bonnet Sensor (Optional) Change FFuel jumper on the heat pump control to “ON” 1 H*3 YMB YZB OD MODELSID MODELS Y2 Second Stage Compressor Thermostat Installer Setup 1-System Type-must be set to 5 – 2 Heat/1 Heat Pump Thermostat Installer Setup 2-Changeover Valve-must be set to 0 – O/B terminal Energized in Cooling C 24 – Volt Common R 24 – Volt Hot Y1 Single Stage Compressor MODULATING FURNACE CONTROL G Fan MODULATING FURNACE Y/Y2 Second or Full Stage Compressor DHUM Dehumidification- Open on Humidity Rise W Modulating Heat Part Numbers: SAP = Legacy 2 2 Move HUMIDISTAT jumper to “YES” if humidistat is to be used. LO COMP Single Stage Compressor (OUT) O Reversing Valve Energized in Cool HI COMP Second Stage Compressor (OUT) Change Hot Heat Pump jumper on the heat pump control to “ON” if Hot Heat Pump Operation is desired. Part Number: S1-2HU16700124 3 External Humidistat (Optional) Open on Humidity Rise 3 Part Numbers: SAP = Legacy 126768 = 031-09137 18395 = 031-01996 340512 = 031-09178 1 TP(8,L)C YP(8,L)C CP(8,L)C LP(8,L)C FIGURE 23: Thermostat Chart - Single Stage Heat Pump – Variable Speed or PSC Modulating Furnace Johnson Controls Unitary Products 368262-UIM-B-1008 O Reversing Valve Energized in Cool C 24 – Volt Common R 24 – Volt Hot W1 OUT First Stage Heat W2 OUT Second Stage Heat Y2 OUT Second Stage Compressor Y1 Single Stage Compressor X/L Malfunction Light Y2 Second Stage Compressor W Auxiliary Heat BS Bonnet Sensor BSG Bonnet Sensor YORKGUARD VI CONTROL TWO STAGE HEAT PUMP Bonnet Sensor (Optional) Change FFuel jumper on the heat pump control to “ON” 1 Part Numbers: SAP = Legacy 126768 = 031-09137 18395 = 031-01996 340512 = 031-09178 1 YZE OD MODELS YZH H*5 H*8 C 24 – Volt Common R 24 – Volt Hot Y1 First Stage Compressor O Reversing Valve Energized in Cool L Malfunction Light Y2 Second Stage Compressor G Fan *DN22H00124*DP22U70124THERMOSTAT ...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - CP8C/CPLC*MP (2.17 mb)