If the furnace is equipped with NOx screens and is to be 7. To measure total static pressure, add supply duct pressure detailed information. used with LP (propane) gas, the screens must be removed to the return duct pressure, add pressure drop across the ‘A’ prior to start-up. coil, and add pressure drop across the filter. Ignore negative 2. Drip leg in the gas line must be installed. signs on the readings. 3. The furnace controls require correct polarity on the power 8. Inlet gas pressure should be 7” w. c. for natural gas and 11” supply and a proper ground. w. c. for propane. Nominal manifold gas pressure is 3.5” w. c. for natural gas and 10” w. c. for propane at max. input. 4. Y & G must be connected to the control board for cooling operation. 9. For downflow application the vent blower must be rotated 90 left or right as shown. 5. External filters are required on all configurations. 6. Electrical or gas entry is available on both casing sides. Models Airflow CFM (Bottom Return without Filters) Minimum Wire Size awg @ 75' One- Way Maximum Over Current Protection0.5" ESP (Nominal) † *D-A* * *C-A* * *B-A* * *A-B** TM9V060B12MP11 600 690 1000 1305 14 15 TM9V080B12MP11 600 680 1000 1290 14 15 TM9V080C16MP11 850 905 1175 1670 14 15 TM9V100C16MP11 870 910 1160 1655 14 15 TM9V100C20MP11 960 1155 1605 2215 12 20 TM9V120D20MP11 960 1160 1595 2180 12 20 Models Input Rate Total Unit Amps Air Temp. Rise Max Input °F Air Temp. Rise Min Input °F Time For 1 ft3 Natural Gas (1030 Btu/Ft3) Seconds (On Max. Rate) Max Min TM9V060B12MP11 60,000 21,000 9 35 - 65 35 - 65 62 TM9V080B12MP11 80,000 28,000 9 35 - 65 30 - 60 46 TM9V080C16MP11 80,000 28,000 12 35 - 65 35 - 65 46 TM9V100C16MP11 100,000 35,000 12 35 - 65 30 - 60 37 TM9V100C20MP11 100,000 35,000 14 35 - 65 35 - 65 37 TM9V120D20MP11 120,000 42,000 14 35 - 65 35 - 65 31 SUPPLYENDRETURNENDLEFTSIDECombustionAirInletCondensateDrain(Downflow) VentConnectionOutletThermostatWiring29.5”28.5” RIGHTSIDECondensateDrain(Downflow) 14” 1” 1.5” 23”CombustionAirInletGasPipeEntryElectricalEntryCondensateDrainOptionalReturnAirCutout(Eitherside) FRONTA33” ClipscanbeflippedintotheuppositionforcoilcabinetorplenumattachmentA-COILFollowallnationalandlocalcodesandstandardsinadditiontothisdocument. Theinstallationmustcomplywithregulationsoftheservinggassupplier, localbuilding, heating, plumbing, andothercodes. Inabsenceoflocalcodes, theinstallationmustcomplywithnationalcodesandallauthoritieshavingjurisdiction. B24.25” .56” .56” 20” 3” 23.8” .56” CombustionAirInlet2” DiameterVentConnectionOutletBDURINGINSTALLATION, DOORSMUSTREMAINONFURNACEWHENMOVINGORLIFTING. VentConnectionOutlet † Other airflows are available. see Tech Guide for all CFM options. * Cool Tap. ** Adjustment Tap. LED INDICATOR CLEARANCES DIMENSIONS Slow Green Flash - Normal operation in...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - TM9V060B12MP11 (234.01 kb)
elektrische Heizungen - TM9V080B12MP11 (234.01 kb)
elektrische Heizungen - TM9V080C16MP11 (234.01 kb)
elektrische Heizungen - TM9V100C16MP11 (234.01 kb)