Anleitung Zusammenfassung
• Refer to the specification section of the heater’s manual, heater dataplate, or contact the factory to determine combustion air ventilation requirements of the heater. • Lack of proper ventilation air will lead to improper combustion. • Improper combustion can lead to carbon monoxide poisoning leading to serious injury or death. Symptom of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing. 1. GENERAL INFORMATION A. The Mr. Heater MH12C and the MH12CS are high pressure propane appliances and are designed to be connected to a 14.1 or 16.4 ounce disposable propane cylinder. Every unit is tested during manufacturing and shipped fully assembled except for the wire stand. B. These heaters are equipped with an automatic Safety Shutoff Valve. The gas flow will automatically stop if the heater fails to operate for any reason. C. Maximum safety and convenience have been built into the Hi- Med-Lo-Off Control Valve/Regulator. The following table lists the approximate BTU’s consumed and the operating hours you can reasonably expect from bulk propane cylinders. D. Model MH12CS is equipped with an igniter for convenient heater lite-off. Valve Position BTU Input Cylinder 14.1 oz. Cylinder 16.4 oz. Hi 14,000 1.4 hours 1.6 hours Med 12,000 1.6 hours 1.8 hours Lo 8,000 2.3 hours 2.7 hours Figure 3 2. FOR SAFE OPERATION A. READ INSTRUCTIONS CAREFULLY: Read and adhere to these instructions. Do not allow anyone who has not read the instructions to assemble, light, adjust or operate the heater. WARNING KEEP THE HEATER OUT OF THE REACH OF CHILDREN B. PROPANE IS VERY FLAMMABLE: In the event of a leak, propane will accumulate and the possibility of a fire is present. Propane gas is scented and its strong odor is readily detectable. Never strike a match or bring any flame or create an electric spark in an enclosure when you smell propane gas. Ventilate the area thoroughly, move the heater outside, find and correct the source of the leak before attempting to light any appliance. If you are unsure of these instructions evacuate immediately and call for help. C. GAS LEAKAGE: If the leak cannot be corrected, do not tamper with the heater, follow the shut down instructions and return the heater to the dealer or address given on last page. WARNING DO NOT STORE PROPANE CYLINDERS NEAR AN OPEN FLAME OR HEAT D. LEAK DETECTION: Before each use of the heater check all fittings and connections with a soap solution to be sure there are no leaks. NEVER, NEVER USE ANY FLAME FOR LEAK TEST. E. CONNECTING HEATER TO PROPANE CYLINDER: Always connect the heater to the cylinder in the outdoors or in a well ventilated area. NEVER connect this heater to a cylinder near an open flame. F. USE OF HEATER: Always operate the heater with the propane cylinder in an upright position on a level noncombustible surface. NEVER place the cylinder on its side when operating the heater. In cooking position cylinder must be 30 degrees from horizontal. G. ATTEND HEATER: Do not leave heater unattended while it is in operation. H. ALWAYS LIGHT HEATER WITH MATCH or “Sparklite” Igniter. I. DO NOT TAMPER: Should the heater not perform properly, such as little or no heat when operating in the “Hi” position, or for any other reason, DO NOT ATTEMPT TO REPAIR OR TAMPER with the heater. Any tampering could make the use of the heater unsafe and dangerous. Return the heater to the dealer or the address given on last page for repair or replacement. J. FOR STORAGE: The heater Hi-Med-Lo-Off regulating valve should always be turned to “Off” when the heater is not in use. Allow at least 15 minutes for cooling before handling and storing. Detach propane cylinder from heater before storing. DO NOT store propane cylinders near open flame or heat. K. DO NOT TRANSPORT OR MOVE APPLIANCE WHILE IN OPERATION OR WHILE HEATER IS ATTACHED. FOLLOW SHUTDOWN AND STORAGE INSTRUCTIONS TO TRANSPORT OR MOVE THIS APPLIANCE. Mr. Heater | Gas-Fired Infra-Red Portable Heater 4 Operating Instructions and Owner’s Manual 3. 3. A. WARNING: This heater is an unvented appliance and MUST be used ONLY in a well ventilated area. NEVER attempt to operate the heater inside any vehicle, camper or enclosure. B. Any combustion process requires and consumes oxygen, and will produce carbon monoxide. THIS HEATER MUST BE USED WITH ADEQUATE VENTILATION. Do not use in a tightly enclosed area. Two openings directly to the outdoors MUST be provided. One HIGH and one LOW. Preferably on opposite sides of the enclosure. EACH OPENING SHALL HAVE A MIMIMUM FREE AREA OF 24 SQUARE INCHES (6” X 4”). Structures of tight construction or tents using fire retardant materials will require larger openings. If any additional fuel burning appliances are operated, ALWAYS provide additional ventilation. Increase the area of each opening by at least 2 square inches for each 1,000 BTU’S per hour of additional input rating. C. WARNING: Provide ample ventilation. This heater consumes air (oxygen). Do not use this heater ...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - MH12C (854.77 kb)