Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung State Industries, modell GPG85 650 NEA

Hersteller: State Industries
Dateigröße: 960.88 kb
Dateiname: 9abe70e2-fae2-4810-89d5-6cc5a4502257.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 5% for every 1,000 feet above sea level. Current Draw (120V, 60Hz, 1 Phase): 6.0 Amps DIMENSIONS AND WEIGHT – ALL MODELS InchesorCMInchesCM950 Lbs. 431.8 KgGASCONN.*** 1. - A80-3/4205.1B73185.4C32-1/481.9D922.9E26-1/267.3F26-1/267.3G93236.2H29-1/274.9I48-1/2123.2DIMENSIONSSHIPPINGWEIGHT *D dimension is for atmospheric vent size (GPG models). **E dimension is for direct and sidewall vent size (GPV models). ***Minimum gas supply pipe is 1-1/4". See Reference Manual, Table 7 for gas supply pipe size. SUGGESTED SPECIFICATION Water heater(s) shall be State Model ________________ or equal, with maximum storage capacity of 85 gallons, an input rating of ___________________ BTU/Hr., a recovery rating of ____ GPH at 100.F temperature rise, and minimum thermal efficiency of 80%. Heater(s) shall meet ASHRAE/IESNA 90.1-1999 requirements for thermal efficiency and standby loss, and meet SCAQMD R1146.2 low-NOx requirements. In addition, heater(s) shall: 1) Include a powered gas burner, redundant main gas valves, gas pressure regulator and flame inspection port. 2) Include a high-temperature limit control, dual-bulb thermostat for accurate temperature control and anti- stacking compensation and a factory-installed AGA rated temperature and pressure relief valve. 3) Be equipped with 1-1/2" NPT water inlet and outlet and a boiler-type handhole cleanout. 4) Shall be constructed and stamped in accordance with ASME Boiler and Pressure Vessel Code and be so marked for a maximum working pressure of 160 psi. 5) Have a glass-lined steel tank with multiple anodes for corrosion protection, and polyurethane foam insulation. 6) Tank shall have a 3-year limited warranty against corrosion as outlined in the written warranty. Venting: GPG heater(s) shall be supplied with a Barometric Draft Regulator for conventional atmospheric venting. GPV heater(s) shall be supplied with an optional vent kit allowing for horizontal sidewall venting or direct venting. Burner and Controls: Burner(s) shall be pre-mix design, with internal FGR and thermal cutoff, separate spark pilot ignition system, integral blocked flue sensor, glass view port, main gas regulator, automatic gas valve, manual test cock and manual gas shutoff. Burner(s) must be factory-installed, tested and started by an Authorized State Startup Agent before being placed into operation. For complete information on limited warranties, consult written warranty, or contact the State Customer Care Center, 1-800-365-0024. State Industries, Inc. reserves the right to make product changes or improvements without prior notice. For Additional Technical Information, PHONE 800-365-0024 STATE WATER HEATERS 500 Tennessee Waltz Parkway, Ashland City, TN 37015Page 2 of 2 SCGSS00205 © 2005 State Industries, Inc. Printed in U.S.A. March 2007R ...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - GPG85 540 NEA (960.88 kb)
elektrische Heizungen - GPV85 540 NEA (960.88 kb)
elektrische Heizungen - GPV85 650 NEA (960.88 kb)
elektrische Heizungen - GPV85 740 NEA (960.88 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien