|
Anleitung Zusammenfassung
[G] 20” (510 mm) [H] 18” (460 mm) N/A [I] 18” (460 mm) [J] 12” (300 mm) N/A Top exit1 , rear h.s. Single-wall connector No connector h.s. [K] 20” (510 mm) [L] 23” (580 mm) [M] 18” (460 mm) [N] 18” (460 mm) [O] 18” (460 mm) [P] 17” (430 mm) Top exit1,2 , rear h.s. Single-wall connec- tor with connector h.s. [K] 20” (510 mm) [L] 18” (460 mm) [M] 17” (430 mm) [N] 18” (460 mm) [O] 12” (300 mm) [P] 15” (380 mm) Top exit1 , rear h.s. Double-wall connector [K] 20” (510 mm) [L] 14” (360 mm) [M] 16” (410 mm) [N] 18” (460 mm) [O] 12” (300 mm) [P] 15” (380 mm) Chimney Connector Clearance: Single-wall connector 18” (460 mm) No connector h.s 13” (330 mm) Single-wall2 connector 13” (330 mm) With connector h.s. 7” (180 mm)3,4Double-wall connector 8” (200 mm) 6” (150 mm) Front Clearance to Combustibles: 48” (1220 mm) (All Installations) 1 Shielding for a top exit stove must include a shield insert to protect the area behind the flue collar. 2 Chimney connector heat shields must extend exactly 24” (610 mm) above the flue collar of the stove. 3 All installations venting straight up to a factory built chimney require a 24” (610 mm) diameter or square ceiling heat shield. The ceiling heat shield should be 24 gauge sheet metal or equivalent mounted on 1” (25 mm) non-combustible spacers 1” (25 mm) below ceiling. 4 Chimney connector heat shields must extend to within 1” (25 mm) or less of the ceiling heat shield for installations venting straight up to a factory-built chimney. In top exit installations using an elbow to vent to the rear, the chimney connector must be shielded over the entire vertical length. 5 If a single-wall oval-to-round adaptor is used, a shield must be used to protect combustibles to the rear of the adaptor. 7001135 13 Dutchwest Distance from Center of Flue Collar to Wall in Top-Exit Installations Dutchwest Convection Heaters equipped with rear heat shields NOTE: These are not clearance distances. These measurements indicate where the centerline of the flue collar will be for various installations. Measurements are from the centerline of the flue collar to the wall, not the wall protector. ABCEDFST427 UNPROTECTED SURFACES Corner Parallel Installations Installations PROTECTED SURFACES Corner Parallel Installations Installations Chimney Connector Side Rear Corner Side Rear Corner MODEL 2460 (Small Convection) Listed, Approved Double-wall Single Wall, with Connector Heat Shields Single Wall, without Connector Heat Shields [A] 33” (840 mm) [A] 33” (840 mm) [A] 33” (840 mm) [B] 18” (460 mm) [B] 13” (330 mm) [B] 23” (580 mm) [C] 25” (640 mm) [C] 22” (560 mm) [C] 25” (640 mm) [D] 23” (580 mm) [D] 23” (580 mm) [D] 23” (580 mm) [E] 10” (250 mm) [E] 11” (580 mm) [E] 13” (330 mm) [F] 15” (380mm) [F] 15” (380 mm) [F] 17” (430 mm) MODEL 2461 (Large Convection) Listed, Approved Double-wall Single Wall, with Connector Heat Shields Single Wall, without Connector Heat Shields [A] 35” (890 mm) [A] 35” (890 mm) [A] 35” (890 mm) [B] 18” (460 mm) [B] 13” (330 mm) [B] 23” (580 mm) [C] 27” (690 mm) [C] 24” (610 mm) [C] 27” (690 mm) [D] 25” (640 mm) [D] 25” (640 mm) [D] 25” (640 mm) [E] 10” (250 mm) [E] 11” (280 mm) [E] 13” (330 mm) [F] 17” (430 mm) [F] 17” (430 mm) [F] 19” (480 mm) MODEL 2462 (Extra-Large Convection) Listed Approved Double-Wall Single Wall, with Heat Shields Single Wall, without Heat Shields [A] 35” (890 mm) [A] 35” (890 mm) [A] 35” (890 mm) [B] 13” (330 mm) [B] 17” (430 mm) [B] 22” (560 mm) [C] 26” (660 mm) [C] 29” (740 mm) [C] 33” (840 mm) [D] 33” (660 mm) [D] 33” (840 mm) [D] 33” (840 mm) [E] 11” (280 mm) [E] 11” (280 mm) [E] 17” (430 mm) [F] 25” (640 mm) [F] 25” (640 mm) [F] 27” (690 mm) 14 7001135 Dutchwest Wall Heat Shield Dimensions DutchWest Convection Heaters, Models #2460 (Small), #2461 (Large), and #2462 (Extra Large) ST428 60” (1525mm) Top Exit 48” (1220mm) Rear Exit 36” (910mm) Centered Behind Stove Spaced 1” (25mm) from Floor 48” (1220mm) 60” (1525mm) Spaced 1” (25mm) from Floor ST429 Fig. 17 Sidewall protection. Fig. 16 Rear wall protection. 60” (1525mm) 48” (1220mm) Spaced 1” (25mm) from FloorST430 Wall Shields Meet at Corner Fig. 18 Corner wall protection. 7001135 15 Dutchwest Assembly Your convection heater requires some assembly. Follow the directions carefully and refer to the parts diagram at the back of this manual. CAUTION: The Dutchwest Convection Heater is very heavy. To prevent personal injury or damage, either to the stove or your home, have two or more people to help move it. Unpack the Parts Remove all loose parts from the firebox and the ash pan. Check to make sure all the parts are included and intact. You should have received: • 1 fully assembled heater body, (with catalytic burner installed at the factory) • 4 legs • 1 ash pan • 1 probe thermometer • 1 ceramic handle assembly • 1 strip of Interam™ gasket (for the catalytic burner) • 1 hardware bag, containing the following parts: • (3) #10 x 1/2” sheet metal screws, (to attach the chimney connector to the flue collar) • (1) 1/8” Al...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - 2460 (1.03 mb)
elektrische Heizungen - 2462 (1.03 mb)