Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Coleman, modell 5040-761

Hersteller: Coleman
Dateigröße: 820.36 kb
Dateiname: 29cc25ab-753c-6894-b9ef-f18ce5d918f6.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Use a 7/16" open end wrench to tighten all hex nuts. Assembly continued. 6Support Tube Step 6 ¦ Install post onto post base. ¦ Decal on post should face front of heater (see photo on front cover). ¦ Attach post to post base using four large screws. ¦ Tighten screws securely. 4 Required Large Screw Step 7 ¦ Load cover onto post. ¦ Slide cover down. (For models without a table, skip to Step 12) Step 8 ¦ Insert table supports into the receptors located in the underside of the table frame. NOTE:Screws must be backed out of the support tubes.Use those screws to attach the clamp in the next step. Step 9 ¦ Using the three screws removed in Step 8, securely attach clamp assembly to support tubes. 3 Required Small Screw Step 10 ¦ Load table onto post by sliding table clamp over post and feed post through center hole of table. ¦ Slide table to desired position. Step 11 ¦ Tighten clamp so table is secured to the post. Friction Sleeve (between clamp and post) Gap in Sleeve should be opposite gap in clamp Assembly continued. Step 12 ¦ Insert studs into screen cover. 3 Req’d Brass Reflector Studs Step 13 ¦ Load head assembly by inserting hose into post. ¦ Insert head assembly into post. ¦ Control knob should be above decal on post. ¦ Attach head assembly to post, and loosely install three screws. ¦ Tighten screws securely. 3 Required Small Screw Step 14 ¦ Remove protective film from all reflector pieces prior to assembly. ¦ Assemble Reflector Assembly 9 Req’d 3 Req’d Acorn Nut Flat Head Screw Edge Pin 1 ¦ Install edge pins into the lower lip of the reflector panel. ¦ Install the Flat Head Screw into the hole from the bottom of the first two reflector panels. ¦ After repeating the above steps to assemble the third reflector panel, set the top cap in place and secure with washers and acorn nuts. Make sure all nuts are snug, but DO NOT OVERTIGHTEN. Step 15 9 Req’d 3 Req’d Washers Edge Pins Upper Stud 2 ¦ Place the other end of the Edge Pin into a second panel of the reflector. Place upper hole in second piece over upper stud. ¦ Loosely install the Flat Head Screw in place with a washer and Acorn Nut. 5 3 4 3 Req’d 3 Req’d Acorn Nut Washers ¦ Support Heater. ¦ Locate assembled reflector on 3 studs (ref. Step 12). ¦ Install washers on studs & securely tighten acorn nuts but do not overtighten! Use a 7/16" nut driver or open-end wrench. 7 Assembly continued. Step 16 • You must provide propane gas and propane tank. Use a standard 20 lb. propane tank only. • Use this heater only with a propane vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58. Your local library or fire department will have this book. • A minimum supply pressure of 11.0 W.C. is required for the purpose of input adjustment for propane gas. • The pressure regulator and hose assembly supplied with the appliance must be used. • The installation must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1. • A dented, rusted or damaged propane tank may be hazardous and should be checked by your tank supplier. Never use a propane tank with a damaged valve connection. • The propane tank must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (DOT). • Never connect an unregulated propane tank to the heater. Standard 20 lb. tank ¦ Tighten Securely. ¦ Install tank. ¦ Attach regulator to tank. ¦ Complete attachment. 8 ¦ Screw regulator onto hose. Do not cross-thread. ¦ Install tank. Leak Check WARNING • Perform all leak tests outdoors. • Extinguish all open flames. • NEVER leak test when smoking. • Do not use the heater until all connections have been leak tested and do not leak. Hose/Regulator Regulator/Cylinder Connection Connection • Make 2-3 oz. of leak check solution (one part liquid dishwashing detergent and three parts water). • Apply several drops of solution where hose attaches to regulator. • Apply several drops of solution where regulator connects to Cylinder. • Make sure all Patio Heater & Light valves are OFF. • Turn Cylinder Valve ON. If bubbles appear at any connection, there is a leak. • Turn Cylinder Valve OFF. • If leak is at Hose/Regulator connection: tighten connection and perform another leak test. If you continue to see bubbles after several attempts, contact 1-800-835-3278 for assistance. • If leak is at Regulator/Cylinder Valve connection: disconnect, reconnect, and perform another leak check. If you continue to see bubbles after several attempts, cylinder valve is defective and should be returned to cylinder’s place of purchase. If NO bubbles appear at any connection, the connections are secure. • Turn Cylinder Valve OFF. NOTE: Whenever gas connections are loosened or removed, you must perform a complete leak test. ¦ Lift cover while installing ¦ Complete installation. remaining cylinder cover section. Mantles ¦ Remove 2 glass panels. ¦ Slip mantle onto ...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - 5040B747 (820.36 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien