|
Anleitung Zusammenfassung
certified for close clearance, “hide-a-way” installation. These units meet requirements for under-the-house warm air delivery for either concrete slab or crawl space construction. See Fig. 1 and Table 1 for furnace dimensions and physical data. See Table 2 for blower data. Table 1 — Dimensions and Physical Data FURNACE 58 BB BD MODEL O ' o _ CO o 120 080 100 125 150 SERIES 100,200,400,500 200,500 APPROX SHIP. WT (lb) 136L142 165 154 208 244 DIMENSIONS (in.) i Width A 16% 20% 16% 20% 24% Length B 26 28 Height C 56% * 60* With Plenum Supply Air Opening E Return Air Open lin9{c Front to Vent Cl H Front to Conn. Cl J Vent Diarn K Min Floor Opening L KXTTNGSr -------- Input (1000 Btuh) Bonn Cap. (1000 Btuh) T emp Rise (F)** ESP (in. wg) Series 100,400 Series 200,500 Series 100,400 Series 200,500 FILTERStt No. Size (in.) BURNERSNo. 14% )4%~ "J 16 2~ - 18% 18% ~2% 4k' 14% Natural or 14% ' 14% r.L. 14% 18% 18% 18% ' 2% 4% 22% 22% 18% -’ropane Gas 6_ 22%“ 80 o o 120 o CO o o 125 150 ! 64 80 *96 ‘ 64” '80 loo 120 _ i - - - r u 70-10° "45-100 .12 J.15 f.20 :so~ ' 45-100 50 16x16x1 -3--T 4~ 2 16x18x1 .. 18x18x1 . 4-y-r- ESP — External Static Pressure *Add 1-1/4 in when installed on combustible flooring with noncombustible base fAdd 18 1/2 in. when installed with 28AE900051 cooling coil plenum; 22 1/2 in when installed with 28AE900061 plenum (series 200 and 500 units only) t Ratings shown for elevations up to 2000 ft For elevations above 2000 ft, deduct 4% of input capacity for each 1000 ft above sea level **Air temp rise may be calculated using the following formula: _bonnet capacity_ At = At 0 24 x specific wt of air x 60 x cfm bonnet capacity 1 08 x cfm |f58BB units use throwaway filters; 58BD units use permanent cleanable filters floor OPENING AIR ROW i SERVICE CLEARANCE 58BB,BD NOTE; AUow safety ciesrance of 1 in. from sides, top, and type B vent; 6 in. from unlisted vent; 1 in. at rear. Fig. 1 — Dimensions Furnaces may be matched with certain 28 Series cooling coils to form combination heating/ cooling systems (see Table 3) and employed with humidifiers and electronic air cleaners to form complete controlled-environment systems. (d) Carrier Cnrnnratinn 1Q79 . COD D D r\ OO I Table 2 — Blower Data BLOWER BB DIRECT DRIVE BD BELT DRIVE FURNACE 58 ~ 080 100 120 080,100 1 125 ! 150 SERIES 100,400 200,500 100,400 [2007500 100,400 200,500 I 200,500 MOTOR Nom Size (in.) Hp PPD BL BMPS* ESP (in. wg)t Air Delivery (max cfm)+ 9x8 10x8 9x8 10x8 __ 9x10 . _ jk 10x10 .. _ 10x8 " “y4 5“ "36" 12x9 6" 42 12x12 3/4 5 " "41" ___% _ V - - 20 .40~ .20" ” .50 "720 1080 .20 ".50 4 .20 1 .50 ~ 4 ' .20 1 .50"" 4 .20 1 .50 .20 730" 30 650 .20 50 .30 1100 1020 890 760 1180 1070 920 1250 1200 980 1120 1260 1380 1620 1800 BL — Belt Length BMPS — Blower Motor Pulley Setting (turns open from closed position) ESP — External Static Pressure PPD — Pulley Pitch Diameter (range 2.1 — 2 9 in ) *Do not close blower motor pulley beyond setting shown fFilter in place JWith motor set at "High" speed NOTE: Refer to Application Data literature for fan performance curves. Table 3 — Furnace-Coil-Plenum Combinations FURNACE COIL PLENUM 58BB080, 58BB100, 58BB120 28AF002 28AE, AF003 28AE, AF004 28AE900051 58BD080, 58BD100 28AF002 28AE, AF003 28AE, AF004 28AE900051 58BD125 28AE, AF003 28AE, AF004 28AE, AF005 28AE900051 58BD150 28AE, AF005 28AE006 28AE900061 NOTE: Adapters not required. Series 100 and 200 units are tested and approved for use with natural gas. Series 400 and 500 are factory built and approved for use with 100% propane gas. Firing of these units with any other gas or mixture is not approved. Furnaces are shipped fully assembled, including built-in draft diverters. Heating/cooling models are equipped with a printed circuit control center, which provides a central control connection point for furnace components and field-added accessories. All internal electric and gas controls are factory assembled and wired. When unpacking unit, should any in-transit damage be observed, file claim with transportation agency. This publication covers furnace and noncombustible base installation. It also shows terminal connections used for wiring accessories to furnace. For accessory installation details, refer to applicable installation literature. INSTALLATION Location Selection When selecting a location for the furnace, observe the following: 1. Install furnace close to chimney and as centralized as possible with respect to distribution system. 2. Locate cooling coil (if used) downstream from furnace. 3. Ensure adequate door clearance for service access. 4. Ensure adequate ventilation. (See Combustion Air.) 5. Follow local and national utility codes. a. Allow safety clearance of 1 in. from sides, top and type B vent; 6 in. from unlisted ...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - 58BD (969.17 kb)