8 Burner Air Shutter Adjustment Adjustment Rod Up(1/8" Open Position) Air Shutter Burner Tube Adjusting Set Screw Adjustment Rod Down(full open position) Figure 14 MAIN BURNER FACTORY AIR SHUTTER OPENING SETTING Model Gas Type Air Shutter Gap EBVI30 Natural Gas 5/16" (7.94mm) Propane 1/2" (12.7mm) EBVI25 Natural Gas 1/16" (1.59mm) Propane 1/2" (12.7mm) CAUTION Carbon will be produced if the air shutter is closed too much. Any damage due to carboning resulting from improperly setting the air shutter is not covered under the warranty. The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation. Table 5 Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased If air shutter is open too far Flame will be blue Air shutter gap should be decreased LOGS, VERMICULITE AND EMBERS Installation Instructions WARNING If logs are not installed according to the directions shown here, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon monoxide (CO) - a colorless, odorless, toxic gas. Carefully install the seven-piece log set into the firebox as shown in these instructions. All logs should fit onto corresponding pins and/or log stoppers. This will ensure a proper flame and safe combustion. Note: Place some vermiculite around burner before installing logs (see Figure 24). The entire bag of vermiculite will NOT be used. Top Left Log Front Center Log Top Right Log Rear Log Front Right Log Front Left Log Center Log Figure 15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 4. Place the Front Left Log onto the two corresponding locating pins 1. Place the rear log onto the two corresponding locating pins at the as shown in Figure 19. back of the fi rebox as shown in Figure 16. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 16 Rear Log 2. Place the Front Right Log onto the two corresponding locating pins as shown in Figure 17. Figure 19 Front Left Log 5. Install the Top Left Log onto the corresponding locating pin and indentation on Center Log as shown in Figure 20. Figure 17 Front Right Log 3. Place the Center Log onto the two corresponding locating pins as shown in Figure 18. Figure 20 Top Left Log 6. Install the Front Center Log over the Front Right Log. The front of log will rest on the burner and the back of log will rest on rear log as shown in Figure 21. Figure 18 Center Log Figure 21 Front Center Log 7. Install the Top Right Log into the corresponding indentations on Front Center Log and front right twig as shown in Figure 22. Figure 22 Top Right Log Figure 22 Top Right Log Figure 23 Embers 9. Place some vermiculite around the logs as shown in Figure 24 (the entire bag of vermiculite will NOT be used). 8. Place the glowing embers on the burner as shown in Figure 23. One package of ember material has been included with this log set You will not need to use the entire bag. IMPORTANT: The quantity and placement of the ember material can affect insert performance therefore it is very important that it be placed as shown in Figure 23. a. Unpackage and divide the fine ember material (mineral wool) into dime-sized fl uffy pieces. b. Distribute the pieces over the top of the front burner ports, filling the Figure 24 Vermiculite area in front of the forward logs. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. MILLIVOLT APPLIANCE CHECKOUT Light the pilot by following the instructions on Page 15 or 16 of this manual. The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. The top 3/8" (10 mm) at the pilot generator (thermopile) and the top 1/8" minimum (tip) of the quick drop out thermocouple should be engulfed in the pilot flame. The flame should project 1" (25 mm) beyond the hood at all three ports (Figure 25). Replace logs if removed for pilot inspection. Proper Pilot Flame Appearance FIREPLACE REQUIREMENTS IMPORTANT: When installing this appliance into a factory built fireplace or heatform, the air flow within and around the fireplace shall not be altered by the installation of the insert (i.e. DO NOT BLOCK louvers or cooling air inlet or outlet ports, circulating air chambers in a steel fi replace liner or metal heat circulator). CAUTION: The factory built firebox must accept the insert without modification other than removing bolted or screwed together pieces such as smoke shelf/defl ectors, ash lips, screen or door tracks, log grates, refractory and damper assemblies. Any fireplace component, which is removed, must be retained so they can be reinstalled to restore the fireplace to its original operating condition. The removal of any part must not alter the integrity of the outer shell of the pre-engineered fireplace cabinet in any way. If any components are removed from (or altered) Room Air Circulation Blower IM...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - EBVI30 (2 mb)