Anleitung Zusammenfassung


• The heater does not monitor the air for CO. RMC-LCNG, RMC-LCLP, RMC-LING, RMC-LILP Specifications RMC-LCNG, RMC-LCLP, RMC-LING, RMC-LILP Specifications Models (Manual & Thermostat) Gas Type Input Rating (Btu/Hr) Variable Regulator Pressure Setting Inlet Gas Supply Pressure Size of Heater Weight Min. Max Min. Max RMC-LC30NG Natural 15,000 30,000 4.0” w.c. 5.0” w.c. 11” w.c. 27”x24”x81/2” 30 lbs. RMC-LC20NG 10,000 20,000 193/8”x227/8 ”x81/2” 22 lbs. RMC-LC10NG 5,000 10,000 151/2”x207/8 ”x77/8” 17 lbs. RMC-LC30LP LP 15,000 30,000 10” w.c. 11.0” w.c. 14.0” w.c. 27”x24”x81/2” 30 lbs. RMC-LC20LP 10,000 20,000 193/8”x227/8 ”x81/2” 22 lbs. RMC-LC10LP 5,000 10,000 151/2”x207/8 ”x77/8” 17 lbs. RMC-LI30NG Natural 6,400 30,000 27”x24”x81/2” 30 lbs. RMC-LI18NG 6,400 18,000 193/8”x227/8 ”x81/2” 22 lbs. RMC-LI10NG 5,500 10,000 151/2”x207/8 ”x77/8” 17 lbs. RMC-LI06NG -6,000 151/2”x207/8 ”x77/8” 17 lbs. RMC-LI30LP LP 6,400 30,000 10” w.c. 11.0” w.c. 14.0” w.c. 27”x24”x81/2” 30 lbs. RMC-LI18LP 6,400 18,00 193/8”x227/8 ”x81/2” 22 lbs. RMC-LI10LP 5,500 10,000 151/2”x207/8 ”x77/8” 17 lbs. RMC-LI06LP -6,000 151/2”x207/8 ”x77/8” 17 lbs. NOTE: For altitude above 2,000 feet, reduce the input ratings (Btu/Hr) 4% for each 1,000 feet above sea level. DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET LOCAL CODES PRODUCT FEATURES RMC-LC30 / RMC-LC20 / RMC-LC10 RMC-LI30 / RMC-LI18 / RMC-LI10 / RMC-LI06 Certified to ANSI Z21.11.2b-2004 Unvented Heaters Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the National Fuel Gas Code ANSI Z223.2, also known as NFPA54. Available from: American National National Fire Protection Standards Institute, Inc. Association, Inc. 1430 Broadway Batterymarch Park New York, NY 10018 Quincy, MA 02269 SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensor Shutoff system (ODS). The ODS pilot is a required feature for vent- free heaters. The ODS pilot shuts off the heater if the normal air oxygen content is reduced below 18%. PIEZO IGNITION SYSTEM This heater has a piezo ignitor. This system requires no matches, batteries or other electrical sources to light the heater. Installation Installation PROVIDE ADEQUATE COMBUSTION AND VENTILATION AIR • This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. • This heater must have fresh air for proper operation. If not, poor fuel combustion could result. Read the following instructions to insure proper fresh air for this and other fuel burning appliances in your home. Modern construction standards have resulted in homes that are highly energy efficient and that allow little heat loss. However, your home needs to breathe and all fuel burning appliances need fresh air to function properly and safely. Exhaust fans, clothes dryer, fireplaces and other fuel burning appliances all use the air inside the building. If the available fresh air supply is insufficient to meet the demands of these appliances, problems can result. Confined Space: The National fuel Gas Code, ANSI Z223.1 / NFPA 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Unconfined Space: An unconfined space is defined in the same standards as a space whose volume is not less than 50 cubic feet per 1000 BTU per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space. Example: 10,000 BTU Legacy heater should only be installed in a room whose volume is more than 500 cubic feet. A room that is 8' x 8' x 8' (512 cubic feet) would be acceptable for a Legacy 10,000 BTU/hour heater. If an additional fuel fired appliance is installed in the same room, the input rating of that appliance should be added to that of the Legacy heater to determine the minimum sized room that should be serviced by both appliances. Unusually tight construction is defined as construction where: a) Walls and ceilings exposed to the outside atmosphere have a continuous water vapour retarder with a rating of 1 perm (6 x 10-11 kg per pa-sec-m2) or less with openings gasketed or sealed; b) Weather stripping has been added on openable windows and doors; and c) Caulking or sealants are applied to areas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, between wall panels, at penetrations for plumbing, electrical and gas lines and at other openings. WARNING: If the area in which the heater may be operated is smaller that that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by on...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - (F) (585.79 kb)
elektrische Heizungen - RMC-LC10LP - 10 (585.79 kb)
elektrische Heizungen - RMC-LC10NG (585.79 kb)
elektrische Heizungen - RMC-LC10NG, RMC-LC20NG(F), RMC-LC30NG(F), RMC-LC10NG(T), RMC-LC20NG(T),(F), RMC-LC30NG(T),(F), RMC-L (585.79 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien