Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Holmes, modell HCH4920

Hersteller: Holmes
Dateigröße: 328.3 kb
Dateiname: a7406cd1-be77-48ed-8994-59653ab217a7.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


14 AWG minimum size and rated not less than 1875 watts. 17. If the heater will not operate, see specific instructions on Auto Safety Shut-off. 18. DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only. PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS AUTO SAFETY SHUT-OFF WITH CERAMIC CONTROL This heater is equipped with a patented, technologically-advanced safety system that requires the user to reset the heater if there is a potential overheat situation. When a potential overheat temperature is reached, the system will automatically shut the heater off. It can only resume operation when the user resets the unit. To Reset the Heater: 1. Turn MODE to OFF and slide switch to manual. 2. Unplug unit, wait 10 minutes. 3. Plug in and turn ON. PRE-OPERATING INSTRUCTIONS 1. Carefully remove your heater from the box. (please save the carton for off-season storage). 2. Make sure the unit is in the OFF position before plugging the heater into the outlet. 3. Place heater on firm level surface. 4. Avoid overloading your circuit by not using other high wattage appliances in the same outlet. At 1500 watts, this unit draws 12.5 Amps. ACCUTEMP™ DIGITAL THERMOSTAT Your heater is equipped with an AccuTemp™ Digital Thermostat that allows you to set your heater to your precise comfort level. Setting the AccuTemp™ thermostat: 1. Make sure the Manual/AccuTemp™ switch is set to AccuTemp™. The LCD display will read 75°. 2. Turn the mode control to LO(Low) or HI(High). 3. Push the temperature set button until the display reads your desired temperature. To increase the temperature push the top button, for lower temperatures push the lower button. When finished setting the temperature, release the button and the display will flash to indicate the thermostat will be set to that temperature. 4. The display will return to existing room temperature and gradually increase until the room has reached your pre-set temperature. 5. If the unit will not start in the AccuTemp™ mode, please make sure the “set temperature” is higher than the current room temperature. NOTE: It is normal for the heater to cycle ON and OFF as it maintains the preset temperature. To prevent the unit from cycling, you need to raise the thermostat setting. When the preset temperature is made, the fan will run for 30 seconds without heat. This cool down process ensures an accurate and consistent temperature reading. If you unplug the heater, you will have to reset the AccuTemp™ thermostat again by following the above instructions. Manual Operation: 1. If you want the heater to run continuously, turn the Manual/AccuTemp™ switch to Manual and adjust the mode control to LO(Low) or HI(High). SETTING THE THERMOSTAT 1. You need to set thermostat on HI(High) to start heater (See fig.#1 and #2). Allow heater to operate and warm up the room. 2. When the desired temperature/comfort level is reached, lower the thermostat setting until the fan/heater stops operating. 3. The control will now automatically maintain the pre-set temperature level by turning the heater ON and OFF. Note: It is normal for the heater to cycle ON and OFF as it maintains the preset temperature. To prevent the unit from cycling, you need to raise the thermostat setting. Figure 2 ACCUTEMP™ CLOSE-UP HEAT CONTROLS OFF LOW 1000W FAN HI 1500W MODE CONTROL THERMOSTAT TEMPERATURE RANGE DISPLAY CLEANING/MAINTENANCE During Season Care: Always unplug the heater, before moving or cleaning. 1. Carefully wipe the unit with a soft, damp cloth. Please be very cautious near the motor and heating elements. 2. After cleaning, be sure to completely dry the unit with a cloth or towel. After Season Care: 1. Store heater in a cool, dry location. 2. Holmes® recommends that you store the unit in its original carton. TROUBLESHOOTING If your heater fails to operate: • Make sure the electrical outlet or circuit breaker is working. • Check for obstructions. If you find an obstruction turn the heater OFF, and unplug the unit. Carefully remove the obstruction and follow the reset instructions. • The thermostat might be set too low. Adjust the thermostat until the heater restarts. • Make sure selector is in LO(LOW) or HI(HIGH) setting. If your heater fails to oscillate: • Make sure the oscillation switch is in the full-circle position. Please DO NOT attempt to open or repair the heater. Please see the Warranty for Service Instructions. A. ACCUTEMP™ THERMOSTAT B. ACCUTEMP™ DIGITAL LCD DISPLAY C. POWER LIGHT/ MODE D. MODE CONTROL E. CARRY GRIP F. AIR FILTER G. REAR GRILL PANEL H. OSCILLATION BASE I. MANUAL/ ACCUTEMP SWITCH J. OSCILLATION SWITCH Figure 1 A B C J I D E F G H SERVICE INSTRUCTIONS 1. Do NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. 2. If you need to exchange the unit...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien