Anleitung Zusammenfassung


THE STEAM CAN CAUSE BURNS. 9. To shut down the unit, press the ON switch into the off position. The steam generator will then drain. You may also switch off the pilot switch to conserve energy. 10. If the HY-5G Steamer behaves as described, the unit is functioning correctly and ready for use. Automatic Operation of Pilot Once the pilot burner is lit, it essentially functions as a standing pilot. In this state, if the pilot is accidentally extinguished (by a very strong gust of wind for example), it will re-ignite automatically. The unit will completely shut down for a few seconds while the pilot is re-ignited. Then the unit will come back on and resume operation in the mode and with the (running) timer value existing just prior to shutdown. The pilot switch may be turned off during “off hours” to conserve energy. After the unit has been running, if the pilot burner ever fails to re-ignite automatically within 90 seconds, wait 5 minutes before you attempt to reactivate it. In the unlikely event that ignition problems persist, contact your authorized Groen Service Agency. NOTE: For operation at high altitudes (2000 feet and above) please consult the Groen Food Service Engineering Department. 9 OM-HY-5G Operation WARNING ANY POTENTIAL USER OF THE EQUIPMENT MUST BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES. A. Controls Operator controls are on the front right of the unit. The HY-5G control panel has the following touch pads and indicator lights: ! The ON/OFF touch pad gets the HyPerSteam ready for use, or shuts it off. ! The READY indicator light shows that the steam generator is at standby temperature and the cavity is hot enough to begin steaming. ! The CLEANING indicator light is lit when the unit is operating in the cleaning mode. ! The SERVICE indicator light shows when the water level probes have stopped working, and need to be cleaned (normally an indication of lime deposits). When one probe fails, the SERVICE light flashes briefly every few seconds, but the unit will continue to operate. De-lime the unit as soon as possible. If the problem continues, both probes may fail. Then the steamer stops working, the light will flash repeatedly and the beeper will sound. At this point you must turn off the power and contact an Authorized GroenService Representative for repair. ! The HI TEMP indicator light comes on when the steam generator is too hot. The unit will automatically shut off, and cannot be turned on again until the steam generator cools and the HI TEMP indicator light goes out. ! The TIMING indicator light stays on when the timer is running. ! The CLEAN touch pad is used to start the automatic 50 minute cleaning cycle. 10 OM-HY-5G The timer is used in three ways: 1 In the OFF position the steam generator stays at a low boil or “holding” temperature. 2 When a cook time is set, the unit steams until the timer runs down to OFF. At that time steaming stops, a red light comes on and a beeper sounds. 3 With the timer turned to the ON position, the unit steams continuously. The green light stays lit. The steamer will not time down. B. Operating Procedure 1. Press the ON/OFF touch pad for the steamer. The steam generator will fill, and heat until the READY light comes on. (About 8-10 minutes.) 2. Load food into pans in uniform layers. Pans should be filled to about the same levels, and should be even on top. 3. Open the door and slide the pans onto the supports. If you will only be steaming one pan, put it in the middle position. 4. Close the door. With the READY indicator lit, take one of the following steps: ! If you want to steam the food for a certain length of time, set the timer for that period. The timer will automatically run the steamer for the set time and then turn it off. A red light will come on and a beeper will sound. Steam production stops. ! If you want to steam continuously, turn the timer to the manual ON position. A green light will come on. The unit will continue steaming until you stop it by turning the timer to OFF. When steaming continuously YOU MUST CONTROL STEAMING TIME. WARNING WHEN YOU OPEN THE DOOR, STAY AWAY FROM THE STEAM COMING OUT OF THE UNIT. THE STEAM CAN CAUSE BURNS. 5. Open the door. Remove the pans from the steamer, using hot pads or oven mitts to protect your hands from the hot pans. 6. To shut down the unit, press the ON/OFF touch pad to OFF. The steam generator will automatically drain. 11 OM-HY-5G Cleaning To keep your HY-5G Steamer in proper working condition, use the following procedure to clean the unit. This regular cleaning will reduce the effort required to clean the steam generator and cavity. A. Suggested Tools 1. Mild detergent 2. Stainless steel exterior cleaner such as Zepper® 3. Steam generator de-liming agent, such as Groen Delimer Descaler (Part Number 114800), commercial Lime-Away® (not the store brand for residential use) or an equivalent. A liquid de-liming agent will be easier to use than crystals or powders. See the warning about chlorides, ...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - HYPERSTEAM (2)HY-5G (4.54 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien