|
Anleitung Zusammenfassung
YES 28 Diagnostic LED’s: SFS Replace Heater Membrane Pad Assembly, reset power to Heater and retry. Heater should fire. A) Is the Stack Flue Switch or Sensor correctly connected to the wiring harness? B) Is the Membrane Pad connected to the correct pins on the Control Board? (See Page 36) Check the J3 and J6 connectors for corrosion on the male pins. Corrosion found? Clean pins Reset power to Heater and retry. Heater should fire. Verify whether you have a Stack Flue Sensor or a Stack Flue Switch (See Page 4-11 in S5066, NO SFS “on” YES YES DONE NO NO Replace Heater Control Board with new style board, reset power to Heater and retry. Heater should fire. Replace Heater Membrane Pad Assembly, reset power to Heater and retry. Heater should fire. Change Low Level Board Programming to “SF1” (See Page 4-11 in S5066, “Sta-Rite Pool/Spa Heater Training and Service Manual”). Were you able to change the device code (SF0 to SF1)? Reset power to Heater and retry. Heater should fire. Check Heat Exchange Coil for liming or low flow. Reset power to Heater and retry. Heater should fire. Did Error Code (E05 or E06) disappear after change? Replace Heater Control Board, reset power to Heater and retry. Heater should fire. NO YES NO NO SENSOR SWITCH Reset power to Heater and retry. Heater should fire. Does the Digital Temerature Display show Error Code “E05” or “E06”? Change Low Level Board Programming to “SF0” (See Page 4-11 in S5066, “Sta-Rite Pool/Spa Heater Training and Service Manual”). Were you able to change the device code (SF1 to SF0)? Check Heat Exchanger Coil for liming or low flow. Reset power to Heater and retry. Heater should fire. Replace switch, reset power to Heater and retry. “Sta-Rite Pool/Spa Heater Training and Service Manual”). Does the Digital Temerature Display show Error Code “E05” or “E06”? YES YES Reconnect correctly. Replace Stack Flue Sensor. DONE NO YES YES NO NO NO YES NO NO NO 29 Burner Troubleshooting SYMPTOM CAUSE REMEDY Loud, high-pitched whine Flame is too rich. Verify pressure tap between gas valve and blower inlet. Turn to Page 19 and verify that the gas regulator setting is 0.2” (0.5cm) wc below the blower inlet pressure. Replace gas orifice with smaller size. Flame is “fluttery.” Exhaust may have acrid smell or burner may fail to stay lit. Flame is too lean. Turn to Page 19 and verify that the gas regulator setting is 0.2” (0.5cm) wc below the blower inlet pressure. Replace gas orifice with larger size. Burner pulsates or surges, especially on ignition. Exhaust vent is too long. Reduce length of exhaust vent and/or number of elbows. Combustion appears normal, but flame does not stay lit. Flame current is not being sensed. Check for wet or damaged igniter with low resistance to ground. Replace with new igniter. Verify burner flameholder is properly grounded. Replace Ignition Control Module. Heat Exchanger Troubleshooting SYMPTOM CAUSE REMEDY Boiling in heat exchanger. May be accompanied by “bumping” sounds. Low water flow to heater. Heat exchanger plugged. Bypass valve stuck open. Thermal governor stuck closed. Service pump and or filter. Service heat exchanger. Correct water chemistry. Service bypass valve. Replace thermal governor. Sweating. Thermal governor failed. Replace thermal governor. 30 31 4 PRESS TAB VENT PILOT OFFOFF ONON 2737 0197 1 3 4 5 6 7 8 10 9 2 12 11 For complete Electrical System parts breakdown (Key Nos. 1 through 4), See Page 34 For complete Burner System parts breakdown (Key Nos. 5 through 9), See Pages 31 and 32 For complete Water System parts breakdown (Key Nos. 10 through 12), See Page 33 Repair Parts are available from your Sta-Rite dealer. If your dealer cannot supply you, call Sta-Rite Customer Service at 1-800-752-0183. For complete Electrical System parts breakdown (Key Nos. 1 through 4), See Page 35 For compete Burner System parts breakdown (Key Nos. 5 through 9), See Pages 32 and 33 For complete Water System parts breakdown (Key Nos. 10 through 13), see Page 34 32 14 15 18 19 20 21 22 23 1 2 3 4 2 5 6 7 9 8 11 12 13 10 16 17 24 25 2692 1196 115/230 PRESS TAB VENT PILOT OFF ON For Heater mounting bolts and clamps, purchase separately Bolt Down Bracket Kit, Part No. 42001-0085S. REPAIR PARTS – BURNER SYSTEM Key No. Part Description Qty. Model SR200NA SR200LP SR333NA SR333LP SR400NA SR400LP SR400HD 1 Combination Gas Control Valve Kit 1 42001-0051S 42001-0051S 42001-0051S 2 3/4” Union 2 38404-4097S 38404-4097S 38404-4097S • Gas Orifice Kit – NG (Incl. Key Nos. 3 and 4)† 77707-0331 77707-0321 77707-0311 3 Gas Orifice – NG* 1 42001-0331 42001-0321 42001-0311 4 Gas Orifice O-Ring 1 U9-370 U9-370 U9-370 • Gas Orifice Kit – Propane (Incl. Key Nos. 3 and 4)† 77707-0361 7707-0351 77707-0341 3 Gas Orifice – Propane* 1 42001-0361 42001-0351 42001-0341 4 • Gas Orifice O-Ring NG to Propane Conversion Kit 1 U9-370 U9-370 U9-370 (Incl. Key Nos. 3 and 4)† 77707-1361 77707-1351 77707-1341 3 Gas Orifice – Propane* 1 42001-0361 42001-0351 42001-0341 4 Gas Orifice O-Ring 1 U9-3...
Dieses Handbuch ist für folgende Modelle:elektrische Heizungen - SR400NA (1.73 mb)
elektrische Heizungen - SR400HD (1.73 mb)
elektrische Heizungen - SR333NA (1.73 mb)
elektrische Heizungen - SR333LP (1.73 mb)