Anleitung Desa, modell TD-41Z

Hersteller: Desa
Dateigröße: 317.69 kb
Dateiname: a63fe7a0-9038-4214-b48c-06e537fdb7e8.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


THIS UNIT MUST BE INSTALLED AS A SEPARATE HEATING ZONE. DO NOT CONNECT THIS UNIT TO AN EXISTING HEATING ZONE OR FEED BOILER WATER DIRECTLY THROUGH THE COIL AS DANGEROUS OVER-HEATING WILL RESULT. DO NOT DRAIN THIS APPLIANCE BEFORE SHUTTING OFF THE SUPPLY VALVE AND OPENING THE RELIEF VALVE OR ANOTHER DOWNSTREAM FIXTURE, AS IT WILL DAMAGE THIS UNIT. ALSO, MAKE SURE A VACUUM BREAKER IS IN PLACE TO AVOID DAMAGING THE LINER. AVOID RISK OF INGESTING A TOXIC FLUID. THE HEAT TRANSFER MEDIUM SHOULD BE WATER. IF GLYCOL MUST BE USED, IT SHOULD ONLY BE USED WITH DOUBLE-WALLED HEAT EXCHANGERS. THIS TANK, LIKE MOST TANKS UNDER PRESSURE, WILL OVER TIME CORRODE OR FAIL AND/OR MAY BURST AND/OR LEAK OR FLOOD (AND IN RARE CASES EXPLODE) WHICH CAN CAUSE SERIOUS OR FATAL PERSONAL INJURY AND PROPERTY DAMAGE. TO MINIMIZE RISK, A LICENSED PROFESSIONAL MUST INSTALL AND PERIODICALLY INSPECT AND SERVICE THE UNIT. A DRIP PAN, CONNECTED TO AN ADEQUATE DRAIN MUST BE INSTALLED IF LEAKING OR FLOODING CAN CAUSE PROPERTY DAMAGE. AS IN ALL PLUMBING PRODUCTS AND WATER STORAGE VESSELS, BACTERIA CAN GROW IN YOUR BOILER MATE TM, ESPECIALLY DURING TIMES OF NON-USE. CONSULT YOUR LOCAL PLUMBING OFFICIAL REGARDING ANY STEPS YOU MAY WISH TO TAKE TO SAFELY DISINFECT YOUR HOME’S PLUMBING SYSTEM. WATER QUALITY CAN SIGNIFICANTLY INFLUENCE THE LIFE OF YOUR PRODUCT, YOU SHOULD TEST FOR CORROSIVE ELEMENTS, ACIDITY, TOTAL SOLIDS, AND OTHER RELEVANT CONTAMINANTS, INCLUDING CHLORINE AND TREAT YOUR WATER APPROPRIATELY TO INSURE SATISFACTORY PERFORMANCE AND PREVENT PREMATURE FAILURE. FOLLOW ALL OF THE INSTRUCTIONS AND RECOMMENDATIONS CONTAINED IN THIS MANUAL, AND THE FOLLOWING ADDITIONAL SPECIFIC WARNINGS. FAILURE TO DO SO IS UNSAFE AND CAN CAUSE SERIOUS SCALDING, EXPLOSION, SERIOUS OR FATAL PERSONAL INJURY AND PROPERTY DAMAGE. FAILURE TO FOLLOW THE ABOVE WARNINGS MAY RESULT IN SERIOUS OR FATAL PERSONAL INJURY AND/OR PROPERTY DAMAGE, AND WILL VOID THE WARRANTY. -3 2. PRE-INSTALLATION CHECKLIST IMPORTANT STEPS AND DECISIONS REQUIRED BEFORE INSTALLATION j THIS PRODUCT MUST BE INSTALLED AND MAINTAINED BY A LICENSED PROFESSIONAL. IN ADDITION TO THE INSTRUCTIONS IN THIS MANUAL, FOLLOW ALL APPLICABLE LOCAL AND STATE CODES OR IN THE ABSENCE OF SUCH CODES, THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND THE NATIONAL ELECTRIC CODE. j DRIP PAN AND DRAIN: To avoid leaking and/or property damage, install with a drip pan connected to an adequate working drain kept clear at all times. j CAUTION: Determine whether your water is corrosive or acidic, and that there are no suspended solids, toxic or other substances or abnormally high chlorine levels in the water that could damage or affect the BOILER MATE™ or the rest of your plumbing system. Do not locate this product where leaking and flooding could cause damage to surrounding property. USE GLYCOL ONLY WITH DOUBLE WALLED HEAT EXCHANGER MODELS. Glycol is a hazardous substance. To avoid seepage or leakage of glycol to surfaces where children or animals can ingest it, use glycol only in double-walled units, so that any leaks will most likely be released to the atmosphere. However, a leak to a surface area may still occur, so any use of glycol must be monitored closely and children and animals should be protected from contact with the unit. Do not connect the BOILER MATE™ domestic supply with baseboard or other space heating units or elements. Any contaminants in the baseboard units will contaminate the potable water in the BOILER MATE™ and also adversely affect its performance. j Wiring Options. Select either a Non-Priority or Priority System: Two options are available when wiring the controls of the BOILER MATE™ in the space heating system (boiler and distribution elements). 1. Non-Priority System - The controls of the BOILER MATE™ must be wired as a separate heating zone with a standard zone valve or a separate circulator dedicated to the BOILER MATE™ "zone". NOTICE: In this non-priority option, the BOILER MATE™ will be supplied just as another zone. This means that if all space heating zones call for hot boiler water at the same time, the BOILER MATE™ may not be supplied with enough hot boiler water to "recover" adequately. The delivery of domestic hot water will be diminished. In many, but not all cases, this is not a problem because the routine oversizing of boiler output is adequate for both loads. 2. Priority System - Under this wiring option the BOILER MATE™ will be supplied before space heating. In limited circumstances, space heating can be lost in the home in this priority mode. Any demand for space heating is postponed until the BOILER MATE™ has reached its set temperature. This delay in supplying the space heating zones is usually not noticed by the inhabitants of the living spaces. However, in the event of certain malfunctions such as circulator or thermostat failure, space heating could be delayed indefinitely. If undetected and uncorrected, freezing damage to piping could result. j Select Circulator versus Z...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - TD-41Z (317.69 kb)
elektrische Heizungen - TD-41ZDW (317.69 kb)
elektrische Heizungen - TD-7Z (317.69 kb)
elektrische Heizungen - TD-7ZDW (317.69 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien