Anleitung Zusammenfassung
” Warmth where it's needed, when it's needed... in a single room or across the house. A constant low level of background heat prevents the fabric of the building from cooling. On demand, this fast-acting appliance raises the temperature to meet your needs, providing total control and the peace of mind that comes with low running costs. PART L and SAP 2005 Key features • Economical use of energy utilising the best of stored and direct acting heating technologies • Contemporary design - looks good in any home • Unobtrusive - takes up no more space than a traditional wet radiator • One-touch electronic controls with child lock facility • Simple ‘+ or -’ touch temperature control for accuracy and flexibility • Rapid response to changing temperature demands • Pre-wired with 2 x 1.6 metre lengths of cable for storage and direct acting power supplies - for ease of connection • Designed for rapid assembly to keep installation costs down • Requires no annual maintenance • Optional central controller for 4 zone pilot wire linked heating system Product Selector ModelReferenceNominalChargeInput Rating OutputAcceptance(Off Peak) Stored heat - maintains low level background heat to keep the fabric of the building warm, utilising economy off-peak electricity Simple integral control on top of the heater - allows easy adjustment to achieve the user’s preferred comfort temperature Radiant heat - rapidly raises temperature to required comfort level on demand The Creda Eco-Response has been developed to help meet the needs of Part L 2006 Building Regulations and provides enhanced SAP scores. Specifiers will benefit from the ‘integrated storage/direct acting heater’ category within table 4a of SAP 2005 which rewards the enhanced controllability of Eco-Response with a 100% efficiency rating, placing this leading technology in heating type 2 with a responsiveness weighting of 0.75. 300kg saving Average carbon saving of up to 300kg per annum when compared to auto slimline storage heaters* *Based on a semi-detached house with a floorspace of 130m2 Input RatingNumberNumber Weight (Radiant Elt.)of Elementsof Bricks ER300 ER400 ER500 75 773301 75 773302 75 773303 0.7kW 1.1kW 1.5kW 9.1kWh 13.65kWh 18.2kWh 1.3kW 1.95kW 2.6kW 0.28kW 0.34kW 0.39kW 2 3 4 8 12 16 65kg 94kg 124kg PW E4ZC 75 770916 4 zone pilot wire central controller 8 +44 (0) 1733 456789 Conventional heaterTechnical Specification Eco-Response Storage radiant heaters Advanced control heating systems Conventional heaterTechnical Specification Eco-Response Storage radiant heaters Advanced control heating systems 1 With a conventional ‘wet’ heating system, when heating goes off, building shell cools. 2 The building shell has to then be warmed again before room feels comfortable. 3 This takes time and energy - slow response. • Elements (Storage) - 650W incoloy sheathed, mineral filled elements • Element (Direct Acting) - cable-on-foil thin facia panel • Thermostat (Input) - integral electronic charge limiter Maximum core temperature 670oC/690oC at full charge • Thermostat (Output) - integral electronic thermostat with child lock facility • Thermal Insulation - Carbowool 128kg/m2, Microtherm G and calcium silicate • Energy Retention Cells - high density bonded magnetite • Protection (Storage) - automatic reset core limit thermostat and manual over-temperature cut out • Protection (Direct Acting) - automatic reset limit thermostat and automatic reset over-temperature cut out • Finish - white polyester and zinc coated steel with grey base • Cable (Storage) - 1.6m 2.5mm2 3 core • Cable (Direct Acting) - 1.6m 0.75mm2 2 core • Supply - 230/240V AC single phase Eco-Response 1 It is smarter to maintain low level background heat. 2 The room temperature can be raised quickly and efficiently when needed. 3 Economical. Responsive. Intelligent. Control options 4 zone pilot wire central controller Allows 7 day programming of comfort/setback time settings of multiple pilot wire linked heaters in up to 4 separate zones. Ref: 75 770916 Dimensions ModelHeight AWidth BDepth CFeet Position D ER300 712mm 600mm 130mm+10mm 295mm ER400 712mm 830mm 130mm+10mm 523mm ER500 712mm 1060mm 130mm+10mm 751mm Minimum clearance required • 75mm either side of heater • 150mm in front of the heater • 250mm directly above the heater Matching TPRIII E Electronic panel heaters also available for pilot wire linked heating systems (See page 12-13). +44 (0) 1733 456789 Contour100 Electronic panel heater Advanced control heating systems Contour100 Electronic panel heater Advanced control heating systems Technical Specification “The all new Contour100 panel heater range offers high quality build and panel finish with contemporary radiator styling. ” Contour100 panel heaters incorporate electronic thermostatic controls which allow very precise regulation of room temperatures. Key features • Contemporary radiator styling • Electronic thermostatic control, accurate to +/-0.3OC • ...