Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung FMI, modell FVFM27PR

Hersteller: FMI
Dateigröße: 724.51 kb
Dateiname: 98a9ba91-36f2-7e64-a98e-e8738545f256.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Open damper or window to vent smell. This will only last a few hours. Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the High heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat. WARNING: Damper handle will be hot if heater has been running. 1. STOP! Read the safety information, column 1. 2. Make sure manual shutoff valve is fully open. 3. Set switch in OFF position. WARNING: Burners will come on automatically within one minute when the selector switch is in the ON position after the pilot is lit. 4. Press in and turn control knob clockwise to the OFF position. 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step. 6. Press in and turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 21). Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system. 7. With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure on page 15. Flame Adjustment Knob OFF PILOT ON LO IHAUTO OFF ON Control Knob Ignitor Button Selector Switch Figure 21 - Control Knob and Ignitor Button Location (Shown as Supplied, No Control Options) 14 OWNER’S MANUAL OPERATING HEATER Continued 8. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 through 8. 9. Slightly push in and turn control knob counterclockwise to the ON position. 10. Wait one minute and switch selector switch to the ON position to light burners. Note: AUTO is only functional when using FWMT1 or FWMS2 optional accessories. 11. Set flame adjustment knob to any level between HI and LO. CAUTION: Do not try to adjust heating levels by using the manual shutoff valve. WARNING: Make sure the selector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with selector switch in the ON position. Pilot Burner Ignitor Electrode Figure 22 - Pilot TO TURN OFF GAS TO APPLIANCE Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2a. Set selector switch in the OFF position. 2b. If Using Optional Hand-Held Remote: Set selector switch in the OFF position to prevent draining battery. Shutting Off Burners Only (pilot stays lit) You may shut off the burners and keep the pilot lit by doing one of the following: 1. Turn control knob clockwise to the PILOT position. 2. Use remote control manual OFF button. 3. Set selector switch in the OFF position. MANUAL LIGHTING PROCEDURE 1. Follow steps 1 through 6 under Lighting Instructions, page 14. 2. Depress control knob and light pilot with match. 3. Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, column 1. OPTIONAL REMOTE OPERATION Note:All remote control accessories must be purchased separately (see Accessories, page 21). Follow instructions included with the remote control. Thermostat Control Operation (Optional FHRCT Only) The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO. The burners will turn on and off automatically to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc. For wall thermostat operation, follow instructions supplied with thermostat accessory FWMT1. For wall switch operation follow instruction supplied with FWMS2. NOTICE: You must light the pilot before using the hand-held remote control unit. See Lighting Instructions on page 14. 1. After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position. Note: The burner may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burners on and off with the hand-held remote control unit. IMPORTANT: Do not leave the selector swi...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien