Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung GSI Outdoors, modell VHC

Hersteller: GSI Outdoors
Dateigröße: 1.67 mb
Dateiname: 614c86d8-a5c4-4d82-a96a-c739d5db86f3.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


3. 4. 5. 6. 7. 8. 9. All wire connections Spark plug gap .125 Pipetrain tightness and gas leaks Flame sensor tight Fuse in place, extra fuse provided Time delay reset Indicator light Pressure gauge Regulator adjusted 10. Shut off valve operates correctly 11. Vapor high limit 12. Unit cycles on to off 13. Heat rise even across transition 14. Unit cycles hi to lo (hi-lo only) 15. Mod valve holds temperature within 1 degree (mod units only). 16. All decals and serial number tag 17. Aesthetic appearance 18. Manual Tester Signature___________________________________ Date_________________________ Deluxe Vane Axial Heater TABLE OF CONTENTS Roof Warning, Operation & Safety..........................................................................4 Warning and Disclaimer.......................................................................................5 Safety Alert Decals..................................................................................................6 Standard Vane Axial Heater Installation................................................................10 Fuel Connection...............................................................................................10 Heater Electrical Installation............................................................................11 Plenum Thermostat Mounting.........................................................................12 Transition Hi-Limit Installation.......................................................................12 Second Heater Installation...............................................................................13 Temperature Heater Specifications.................................................................14 Standard Vane Axial Heater Operation..................................................................15 Standard Heater Operation...............................................................................15 Hi-Lo Heater Operation...................................................................................16 BTU's Per Gauge Pressure (PSI) Propane Models (Approximate)..................16 BTU's Per Gauge Pressure (PSI) Natural Gas Models (Approximate)............17 Adjusting The Vaporizor..................................................................................18 Modulating Valve Operation............................................................................19 Wiring Schematic...................................................................................................20 Heater Parts............................................................................................................21 18" Gas Heater..................................................................................................22 24" & 26" Gas Heater.......................................................................................24 28" Gas Heater..................................................................................................26 Control Box......................................................................................................28 Axial Propane Vapor Pipetrain.........................................................................30 Axial Natural Gas Pipetrain.............................................................................32 Axial Propane Vapor Hi-Lo Pipetrain..............................................................34 Axial Natural Gas Hi-Lo Pipetrain...................................................................36 Axial LP Pipetrain.................................................................................................38 Notes.............................................................................................................................40 Warranty..................................................................................................................41 WARNING AND DISCLAIMER Deluxe Vane Axial Heater GSI DOES NOT WARRANT ANY ROOF DAMAGE CAUSED BY EXCESSIVE VACUUM OR INTERNAL PRESSURE FROM FANS OR OTHER AIR MOVING SYSTEMS. ADEQUATE VENTILATION AND/OR "MAKEUP AIR" DEVICES SHOULD BE PROVIDED FOR ALL POWERED AIR HANDLING SYSTEMS. GSI DOES NOT RECOMMEND THE USE OF DOWNWARD FLOW SYSTEMS (SUCTION). SEVERE ROOF DAMAGE CAN RESULT FROM ANY BLOCKAGE OF AIR PASSAGES. RUNNING FANS DURING HIGH HUMIDITY/COLD WEATHER CONDITIONS CAN CAUSE AIR EXHAUST OR INTAKE PORTS TO FREEZE. Heater Operation Thank you for choosing a GSI product. It is designed to give excellent performance and service for many years. This manual describes the operation of the GSI Deluxe Vane Axial Heater. Many models are available to accommodate low, medium or high temperature grain conditioning. The principal concern of The GSI Group Inc. (GSI) is your safety and the safety of others associated with grain handling equipment. This manual is written to help you understand safe operating procedures, and some of the problems that may be encountered by the operator or other personn...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - VLC (1.67 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien