Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Dimplex, modell PLX 500, WTI 500

Hersteller: Dimplex
Dateigröße: 293.1 kb
Dateiname: 49c275d2-3d70-4997-8e93-6140adc9a9ab.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


1 IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLYAND RETAINED FOR FUTURE REFERENCE Important Safety Advice When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electrical shock, and injury to persons, including the following: IMPORTANT – The wall brackets supplied with the appliance must be used. IMPORTANT – If the heater is installed in a room containing a bath or shower, it must be so installed that switches and other controls cannot be touched by a person using a bath or shower. Do not use outdoors. Do not locate the heater immediately below a fixed socket outlet or connection box. Do not cover the heater. Do not place material or garments on the heater, or obstruct the air circulation around the heater, for instance by curtains or pushing furniture up against the heater, as this could cause overheating and a fire risk. NEVER cover or obstruct in any way the heat outlet slots at the top of the heater or the air inlet slots in the base of the heater. The heater carries the Warning symbol indicating that it must not be covered. WARNING – THE SURFACES OF THIS HEATER CAN BE HOT. Momentary contact with any part of the heater should not cause injury. However, aged or infirm persons or young children should not be left unsupervised in the vicinity of the heater unless a suitable guard is fitted. This appliance is not intended for use by children or other persons without assistance or supervision if their physical, sensory or mental capabilities prevent them from using it safely. Children should be supervised to ensure that they do not play with the appliance. Note that due care and consideration must be taken when using this heater in series with a thermal control, a program controller, a timer or any other device that switches on the heat automatically, since a fire risk exists when the heater is accidentally covered or displaced. If the supply cord is damaged it must be replaced by the manufacturer or service agent or a similarly qualified person in order to avoid a hazard. Electrical WARNING – THIS APPLIANCE MUST BE EARTHED The electrical installation must be carried out by a competent electrician, and be in strict accordance with the current I.E.E. regulations for Electrical Equipment in Buildings. The heater is fitted with a length of flexible cable type H05VVF size 3 x 1.0mm2 on models PLX 500 - 2000 and size 3 x 1.5mm2 on PLX 3000 models, for connection to the fixed wiring of the premises through a suitable connection box positioned adjacent to the heater. The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3mm. Supplementary Earth Bonding Should Equipotential Earth Bonding be required the earthing conductor in the supply cord is deemed to provide the supplementary bonding connection (see Regulation 54703- 05, 16th Edition I.E.E. Wiring Regulations). General The PLX Convector is designed for wall mounting on the wall brackets supplied. It should only be operated when in the upright position as shown. All models are splashproof to IP24 standard. Models PLX…TI are fitted with a 24 hour programmable timer. Models PLX…TX are fitted with a 7 Day programmable timer. Models PLX…NC are fitted with no controls, for use with external thermostatic or programming controllers. Before connecting the heater check that the supply voltage is the same as that stated on the heater. Fig. 3 Fig. 4 Wall Mounting IMPORTANT – The wall brackets supplied with the appliance must be used. The heater should be positioned observing the minimum clearances stated around the heater - see Fig. 1. DO NOT locate the heater immediately below a fixed socket outlet or connection box. 1. Remove wall mounting bracket from the back of the heater by depressing the spring latch at the top of each bracket - see Fig. 2. 2. Fix the wall bracket securely to the wall through the four screw holes provided. 3. Present the heater to the wall bracket, and engage lower slots in the back with bracket. 4. Raise the heater to upright position and push the heater onto brackets to engage top latch. Access to the controls The controls cover (see ‘x’ in Fig. 1) on your heater has a latch which may be locked shut if desired using a small bladed screwdriver - see Fig. 3. To open the cover insert the blade of the screwdriver in the small slot and rotate a quarter of a turn clockwise to disengage the latch. The cover may then be hinged back towards the wall for access to the controls. Operation - Thermostat only models Control of Output and Temperature (see Fig. 4) The switch marked O and I controls the electricity supply to the heating elements. The OFF position is marked O. The switch marked I - II (half heat – full heat) provides a choice of output as desired. Fig. 2 255 MIN Thermostat Operation The heater is fitted with an adjustable thermostat enabling the room temperature to be controlled by adjusting the setting accordingly. The * set...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - WTI 500 (293.1 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien