Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Roberts Gorden, modell VANTAGE HE HE-125

Hersteller: Roberts Gorden
Dateigröße: 163.23 kb
Dateiname: Vanateg-HE-Tech-Spec-NA-Rev-E.pdf

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


■ Effective in high moisture environments due to durable components ■ Burner box design with protective enclosure for controls minimizes exposure to dirt and moisture from combustion air ■ Approved for indoor and outdoor installations Design flexibility achieved with broad range of burner inputs and tube lengths ■ Diagnostic capability incorporated in burner design Vantage' HE The infrared Heater Designed for Harsh Environments Quality in Any Language TM ROBERTS GORDOff Burner End View |(34 cm)| Side View Top View Reflector - Turbulator (some models) - Length“A”- ■ Overall Length “C”- VANTAGE® HE Model HE-40 HE-6O HE-SO HE-1OO HE-125 HE-150 HE-175 Length of Straight Tube (ft, in) A 10 20 0 4 0 3 0 2 50 60 Length of U-Tube (ft, in) B N/A 11,7 11,7 16,7 21,7 26,7 31,7 Overall Length of Straight Tube (ft, in) C 11,5.5 21,5.5 21,5.5 31,5.5 41,5.5 51,5.5 61,5.5 Overall Length of U-Tube (ft, in) D N/A 13,0.5 13,0.5 18,0.5 23,0.5 28,0.5 33,0.5 Input (Btu/hj x (1OOO) 40 60 SO 100 125 150 175 Fuel Natural Gas (NG) or Propane Gas (LP) Inlet Pressure (in wc) NG min. 4.6 4.6 4.6 4.6 4.6 4.6 5 LP min. 11 11 11 11 11 11 11 14 maximum for NG & LP Gas Connection NPT 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” Electrical Supply 120 V 60 Hz, 1 A (Run) 5 A (Start) Heat Exchanger Tubing 10 ft Sections 4И dia, 16 Gauge, First 10 ft ALUMI-THERM® Steel Tubing (Remaining Heat Treated Aluminized Steel Tubing) Exhaust Flue 4” dia Reflector and End Caps .024 Stainless Steel Type 304 [Optional - .024 Aluminum) Control System Honeywell® SmartValve® II Combines Gas Valve and Hot Surface Electronic Ignition Control Fully Automatic, Four-Try, 100% Shut-Off, Prepurge, Auto Reset, LED Indicator Status Approved As Indoor and Outdoor (Vented or Unvented) Certification ANSI Z83.20/CSA 2.34, 2.17, 2.20 Warranty Three-Year Limited (Refer to Installation, Operation and Service Manual for Details) Weights Burner (lb) 40 Vent Cap Package Included (lb) 4 Overall Length of Tube and Accessory Packages (ft) iO 20 30 40 5O 6O Aluminized Tube with Aluminum Reflector (lb) 52 86 120 161 206 240 Aluminized Tube with Stainless Steel Reflector (lb) 66 113 152 208 265 304 U-Tube Packages Aluminized Tube with Aluminum End Caps Aluminized Tube with Stainless Steel End Caps (lb 19 20 Clearances to Combustibles* (in) HE-4O HE-60 HE...

Dieses Handbuch ist für folgende Modelle:
elektrische Heizungen - VANTAGE HE HE-100 (163.23 kb)
elektrische Heizungen - VANTAGE HE HE-150 (163.23 kb)
elektrische Heizungen - VANTAGE HE HE-175 (163.23 kb)
elektrische Heizungen - VANTAGE HE HE-40 (163.23 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien