INSTALLATION OPTIONS There are three options for mounting this heater. A. Mounting heater to wall B. Mounting heater to optional hearth base C. Mounting heater to optional mantel (some mantels require the hearth base) A. MOUNTING HEATER TO WALL Mounting Bracket The mounting bracket is located in the package tray. Remove mounting bracket from tray. Methods For Attaching Mounting Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level. WARNING: Maintain minimum clearances shown in Figure 11. If you can, provide greater clearances from floor and joining wall. 2. Mark screw locations on wall (see Figure 11). Note:Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall. Attaching Thermostat Sensing Bracket To Wall Bulb Only use last hole on each end of mounting 1. Remove thermostat sensing bulb from bracket to attach bracket to wall. These two holders inside heater. Route through holes are 16 inches apart from their centers. slot opening in bottom of heater. Attach mounting bracket to wall in one of two ways. 2. Place clamp on thermostat sensing bulb as shown in Figure 10. Clamp is pro-1. Attaching to wall stud vided in hardware package. 2. Attaching to wall anchor 18 3/4" Min. 11" Min. 16" Adjoining WallOnly Insert Mounting Screws Through Last Hole On Each End Floor 3. Snap clamp into upper mounting hole Attaching To Wall Stud: This method pro- as shown in Figure 10. Mounting hole vides the strongest hold. Insert mounting is located on lower left edge on back screws through mounting bracket and into Figure 11 - Mounting Bracket Clearances of heater. Make sure the thermostat sensing bulb is pointing up. wall studs. Attaching Mounting Bracket To Thermostat Sensing Bulb Clamp Attaching To Wall Anchor: This method Wall allows you to attach mounting bracket to hollow walls (wall areas between studs) or Note:Wall anchors, mounting screws, and to solid walls (concrete or masonry). spacers are in hardware package. The hardware package is provided with heater. Decide which method better suits your needs. Either method will provide a secure hold for Attaching To Wall Stud Method the mounting bracket. For attaching mounting bracket to wall studs 1. Drill holes at marked locations using 9/64" drill bit. Figure 10 - Attaching Thermostat Sensing 2. Place mounting bracket onto wall. LineBulb up last hole on each end of bracket with holes drilled in wall. 3. Insert mounting screws through bracket and into wall studs. 4. Tighten screws until mounting bracket is firmly fastened to wall studs. Continued 9 For more information, visit ® PROPANE/LP GAS RESIDENTIAL HEATERS INSTALLATION Continued Attaching To Wall Anchor Method For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry) 1. Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep. 2. Fold wall anchor as shown in Figure 12. 3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT:Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. 5. Place mounting bracket onto wall. Line up last hole on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is firmly fastened to wall. Figure 12 - Folding Anchor Figure 13 - Popping Open Anchor Wings For Thin Walls Placing Heater On Mounting Bracket 1. Locate two horizontal slots on back panel of heater. 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket. Horizontal Slots Stand-Out Tab Mounting Bracket (attached to wall) Figure 14 - Mounting Heater Onto Mounting Bracket Installing Bottom Mounting Screws 1. Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 15). 2. Mark screw locations on wall. 3. Remove heater from mounting bracket. 4. If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching To Wall Anchor Method. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64" drill bit. 5. Replace heater onto mounting bracket. 6. Place spacers between bottom mounting holes and wall anchor or drilled hole. 7. Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole. 8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note:Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 12 and 1...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien