Anleitung Generac Power Systems, modell 005223-0

Hersteller: Generac Power Systems
Dateigröße: 4.14 mb
Dateiname: 8b86cab8-f440-4cbf-ae47-d6ade1c0f7a5.pdf

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


REGULATOR (I/N 3) AS SHOWN IN ILLUSTRATION IS SET UP FOR NATURAL GAS APPLICATION. 2. TO CONFIGURE REGULATOR FOR LP VAPOR, SWITCH HOSE BARB, HOSE CLAMP (I/N 13) AND HOSE (I/N 14) FROM “OUT-1” TO “OUT-2”. REPLACE PIPE PLUG FROM “OUT-2” TO “OUT-1”. USE PIPE SEALANT ON HOSE BARB AND PIPE PLUG. MAKE SURE TO KEEP PORTS FREE FROM DEBRIS DURING RECONFIGURATION PROCESS. 3*. FOR LP VAPOR APPLICATION SUBSTITUE LPG FUEL INLET DECAL P/N 050280 FOR NG FUEL INLET DECAL P/N 050279 (ITEM17). 4 . WHEN SWITCHING FUEL TYPES, THE PROPER DIP SWITCH SITTINGS MUST BE MADE TO THE CONTROL PANEL. SEE OWNERS MANUAL, FUEL SECTION FOR MORE DETAILS. 1 2 3 4 0F5853 (XX) 0C2454 0F5849 (XX) 087233 1 68 2 2 REAR WRAP C2 SCREW THF M6-1 X 16 N WA Z/JS DOOR C2 RIVET POP .1875 X .450 SS 5 6 7 8 9 10 11 0E3257 0F5852 (XX) 0F5850 (XX) 0F5851 (XX) 0F3313 0F3312 0F5848 4 2 2 1 1 (REF.) 1 (REF.) 1 SCREW TH-FRM M6 W/CAP SHKPRF W DISCHARGE DUCT,LH & RH SIDE C2 FRONT CORNERS C2 DISCHARGE CENTER DUCT C2 DUCT INNER DISCHARGE C2 DUCT INNER DISCHARGE TOP C2 ROOF C2 ALUM 12 0F2786 2 SLITTER C4 13 0F2785 1 SPLITTER LOWER C4 14 0F3364 1 SPLITTER STINGER C2 15 0F4880 2 SUPPORT SPLITTER LH C2 16 0F5049 2 TAB PULL 17 0C2634A 1 ASSEMBLY COVER ACCESS 18 19 20 21 022473 022097 022127 0F3072 3 1 1 16 WASHER FLAT 1/4-M6 ZINC WASHER LOCK M6-1/4 NUT HEX 1/4-20 STEEL INSULATION RETAINMENT HANGER 22 078115 48 WASHER SELF LOCKING DOME 23 0F4051 2 INSULATION DOOR C2 24 0F4051A 1 INSULATION ROOF TOP 25 26 27 0F5048 0E5968 0F3760K 2 1 2 LATCH VISE ACTION 5/16HEX SOCK GASKET EXTRUDED TRIM (440.64” LG) INSULATION SPLITTER 28 0F3760E 2 INSULATION SPLITTER 29 0F4051C 2 INSULATION DUCT 30 31 0F3890B 0F4051B 8 2 RETAINER INSULATION (820) INSULATION DUCT SIDES 32 33 34 0F3890 0F3890A 0F3760L 4 3 1 RETAINER INSULATION (450) RETAINER INSULATION (740) INSULATION LOWER SPLITTER 35 042568 2 SCREW HHC M6-1.0 X 20 G8.8 36 37 38 0912970092 022447 049813 2 2 2 ASSY WIRE 14AWG 26.4" GRN/YEL WASHER SHAKEPROOF INT 1/4 NUT HEX M6 X 1.0 G8 YEL CHR 39 ** 077992 21 NUT HEX LOCK M6-1.0 SS NY INS 40 * 0F6321 1 ROOF RAIN DEFLECTOR 43 *** 0C3397 4 FASTENER RATCHET OPTIONAL COMPARTMENT MATERIALS: ALL P/N’S WITH AN (XX) SUFFIX INDICATE A MULTIPLE MATERIAL AND COLOR OPTION. USE THE FOLLOWING LEGEND TO IDENTIFY THE CORRECT PART NUMBER: PART NO. MATERIAL COLOR 0XXXXXSN STEEL TAN 0XXXXXAN ALUMINUM TAN 0XXXXXSG STEEL GRAY 0XXXXXAG ALUMINUM GRAY * 3.9L ONLY ** ALUMINUM ENCLOSURE NOTE: ALL ENCLOSURE PANELS THAT FASTEN TO THE BASE FRAME MUST BE SECURED USING ITEM 2 & 5 THREAD FORMING FASTENER AND ITEM 39 LOCK NUT. LOCK NUT IS TO BE INSTALLED AFTER THREAD FORMING FASTENER HAS PENETRATED THROUGH EXTRUSIONS IN ENCLOSURE PANELS. ALL ROOF PANELS ARE TO BE SECURED IN THE SAME MANNER. *** 3.0L ONLY Standby Generator Sets Warranty Standby Generator Sets Warranty GENERAC POWER SYSTEMS STANDARD LIMITED WARRANTY FOR HOME STANDBY/LIGHT COMMERCIAL PRODUCT 45kW AND BELOW For a period of two (2) years from the date of sale, or start-up by Authorized/Certified Generac Power Systems Dealer, or branch thereof, Generac Power Systems, Inc. will, at its option, repair or replace any part(s) which, upon examination, inspection, and testing by Generac Power Systems or an Authorized/Certified Generac Power Systems Dealer, or branch thereof, is found to be defective under normal use and service, in accordance with the warranty schedule set forth below. Any equipment that the purchaser/owner claims to be defective must be examined by the nearest Authorized/ Certified Generac Power Systems Dealer, or branch thereof. This warranty applies only to Generac Power Systems Generators used in "Standby" applications, as Generac Power Systems, Inc. has defined Standby, provided said generator has been properly installed and inspected on-site by appropriate personnel. Scheduled maintenance, as outlined by the generator owner's manual, is highly recommended. This should be performed by an Authorized/Certified Generac Power Systems Dealer, or branch thereof. This will verify service has been performed on the unit throughout the warranty period. WARRANTY SCHEDULE YEARS ONE and TWO — Limited comprehensive coverage on mileage, labor, and parts listed. • - ALL COMPONENTS *Start-up and/or On-line Registration, or Registration Card, along with Proof of Purchase, must be performed and/or sent in. Guidelines: • Any and all warranty repairs and/or concerns, must be performed and/or addressed by an Authorized/Certified Generac Power Systems Dealer, or branch thereof. • A Generac Power Systems, Inc. Transfer Switch is highly recommended to be used in conjunction with the genset. If a Non - Generac Power Systems, Inc. Transfer Switch is substituted for use and directly causes damage to the genset, no warranty coverage shall apply. • All warranty expense allowances are subject to the conditions defined in Generac Power Systems Warranty, Policies, and Procedures Flat Rate Manual. • Units that have been resold are not covered under the Generac Power Systems Warrant...

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien