Login:
Stimmen - 2, Durchschnittliche Bewertung: 5 ( )

Anleitung Braun, modell 8585

Hersteller: Braun
Dateigröße: 6.71 mb
Dateiname: Braun-8590-8585-Pdf-Rus.Pdf
Unterrichtssprache:ruplhrentrfrcs
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


It ensures unsurpassed closeness and comfort for you and optimum care for your shaver: • The system automatically adapts to any voltage worldwide. • The system recognizes when cleaning of your shaver is required, and automatically recognizes which of the three cleaning programs is appropriate. • While the shaver is connected to the mains, the system automatically takes care of charging and discharging in a way that is optimized for the shaver’s battery capacity and life span. • The system takes care of lubrication of the shaver’s cutting parts. • The system tells you when to replace the shaving foil and cutter block. Warning Your Activator is provided with a low-voltage adapter. Therefore you must not exchange or manipulate any part of it. Otherwise there is risk of electric shock. In order to avoid any leakage of the cleaning fluid, place the Clean&Charge station on a flat, stable surface. Do not tip, move suddenly or transport the station in any way if a cleaning cartridge is installed. Do not place the station in a mirror cabinet, nor store it over radiators, nor place it on polished or laquered surfaces. Do not expose to direct sunlight. The station contains highly flammable liquid. Keep it away from sources of ignition. No smoking. Keep out of reach of children. Do not refill cartridge. Use only original Braun refill cartridge. 4 Description 1. Low-voltage adapter 2. «start cleaning» button 3. Station-to-shaver connecting contacts 4. Station lift button for cartridge exchange 5. Display for cleaning programs 6. Display for cleaning fluid status 7. Station mains socket 8. Cleaning cartridge 9. Shaver foil protection cap 10. Shaver foil 11. Cutter block 12. Foil release buttons 13. Long hair trimmer 14. Shaver-to-station connecting contacts (shaver backside) 15. Switch 16. Shaver charging lights (green) 17. Shaver low-charge light (red) 18. Pilot light 19. Shaver mains socket Before shaving If you wish, you may start shaving right away (if the shaver is charged, see section «Shaver indicator lights»). However, we recommend to follow the procedure described here: • Using the low-voltage adapter (1), connect the mains socket of the Clean&Charge station (7) to the mains. • Press the station lift button (4) to open the housing. • Hold the cleaning cartridge (8) down on a flat, stable surface (e.g. table). • Carefully remove the lid from the cartridge. • Slide the cartridge into the base of the station as far as it will go. • Slowly close the housing by pushing it down until it locks. 5 a Ml \J empty b empty c 1 \Jf empty MSf% W---- clean a eco b & normal 0 intensive d L. "" —Jd clean / eco £ normal w / /. intensive The display for cleaning fluid (6) will show how much cleaning fluid is in the cartridge: a) Cleaning solution sufficiently available b) Up to 7 cleanings left c) New cartridge required Make sure the foil protection cap (9) is removed from the shaver. Insert the shaver head down into the station (the contacts on the back of the shaver (14) will correspond to the contacts in the station (3)). If necessary, the system will now charge the shaver. Also, the cleaning status will be automatically analyzed and one of the four diodes of the cleaning program display (5) will light up: a) The shaver is clean b) Eco(nomic), i.e. short cleaning required c) Normal cleaning required d) Intensive cleaning required If the system has selected one of the three cleaning programs, it will not start until you push down the «start cleaning» button (2). This locks the shaver into the station and starts the cleaning process. We recommend cleaning after each shave. While the cleaning is in progress, the respective cleaning program light will flash. Each cleaning consists of several cycles (where the cleaning fluid is flushed through the shaver head) and a heat drying period. The total cleaning time is 33 to 50 minutes. Cleaning processes in the Clean&Charge should not be interrupted. While the shaver is drying, the metal parts of the shaver may be hot. Also, if the shaver is taken out prematurely and is not dry, its electronics could be harmed. When the program is finished, the blue «clean» light will shine. You can release the shaver by pushing the «start cleaning» button. Your shaver is now clean, charged and ready for use. 6 Shaving If the shaver is locked into the Clean&Charge station, push the «start cleaning» button (2) to release the shaver and take it out. Switch positions off = (switch is locked) Press and push up the switch to operate the shaver: 1 = Shaving with the pivoting head (the pivoting cutting system automatically adjusts to every contour of your face). 2 = Shaving with the pivoting head locked at an angle (to permit shaving in difficult areas, e.g. under the nose). 3 = The long hair trimmer is activated (for trimming sideburns, moustache and beard). Tips for the perfect shave We recommend that you shave before wa...

Dieses Handbuch ist für folgende Modelle:
Rasierer - 8590 (6.71 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien