Anleitung Blue Seal, modell G1100
Hersteller: Blue Seal Dateigröße: 1.29 mb Dateiname: G1100.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
There are settings explained in this manual that should never require to be adjusted, but for completeness and those special cases where these settings are required to change, this manual gives a full explanation as to how, and what effects will result. SECTION PAGE NO. 1. SPECIFICATIONS......................................................................................................... 5 2. INSTALLATION ............................................................................................................ 8 3. OPERATION.................................................................................................................. 10 3.1 Description of Controls 3.2 Explanation of Control System 4. MAINTENANCE............................................................................................................. 13 4.1 Cleaning 4.2 Routine Procedures 5. TROUBLE SHOOTING GUIDE ..................................................................................... 14 6. SERVICE PROCEDURES ............................................................................................. 18 6.1 Fault Diagnosis 6.2 Access 6.3 Replacement 6.4 Adjustment / Calibration 7. CIRCUIT SCHEMATIC .................................................................................................. 38 8. ELECTRICAL WIRING DIAGRAM................................................................................ 40 9. SPARE PARTS.............................................................................................................. 42 IMPORTANT: MAKING ALTERATIONS MAY VOID WARRANTIES AND APPROVALS. (button) Revision 4/F3576 © Moffat Ltd, December 2004 10. PARTS DIAGRAMS ...................................................................................................... 44 10.1 Main Assembly 10.2 Control Panel Assembly 10.3 Ignition Electrode Assembly 10.4 Gas Piping Assembly 11. SERVICE CONTACTS .................................................................................................. 51 APPENDIX A. DOUBLE STACKING INSTRUCTIONS......................................................... 53 APPENDIX B. IGNITION BOX SPECIFICATIONS................................................................ 54 Revision 4/F3576 © Moffat Ltd, December 2004 (button) -4 1. SPECIFICATIONS 1. SPECIFICATIONS MODEL: G1100 70135 1005 310 MWS E1 60 660 1390 715 930 50 205280 E1 MWS GASGAS FRONT SIDE MWS E1 GAS PLAN LEGEND - Electrical connection entry point - Water entry - .” BSP hose connection - Gas connection entry point Dimensions shown in millimetres. Revision 4/F3576 © Moffat Ltd, December 2004 (button) -5 MODEL: G1100-2 FRONT SIDE 1 70135 E MWS MWS 1005 310 1 E 285 280 205 2451690 1 230 930 50 60 1 E MWS E MWS GAS GAS GAS GAS PLAN MWS 1 E GAS LEGEND - Electrical connection entry point - Water entry - .” BSP hose connection - Gas connection entry point Dimensions shown in millimetres. Revision 4/F3576 © Moffat Ltd, December 2004 (button) -6 LOCATION This oven must be installed in an area of adequate air supply. The following minimum clearances for air openings, servicing, operation and installation are to be adhered to: Rear 100 mm Left-hand side 100 mm Right-hand side 300 mm Top 1200 mm OVEN INTERNAL DIMENSIONS Width 730 mm Height 490 mm Depth 600 mm Oven Volume 0.21 m. OVEN RACK SIZE Width 710 mm Depth: 520 mm GAS SUPPLY SPECIFICATION OPTIONS Natural LPG Input Rating 73 MJ/hr 73 MJ/Hr 69 000 Btu/hr 69 000 Btu/hr 20.3 kW 20.3 kW Gas Rate 1.90 m./hr 1.40 kg/hr Inlet Pressure 1.13 kPa 2.75 kPa 4.5”w.c. 11.0”w.c. Burner Pressure (From S/N 275353) 0.90 kPa 2.50 kPa 3.6” w.c. 10.0” w.c. (Up To S/N 275352) 0.89 kPa 2.65 kPa 3.6” w.c. 10.6” w.c. GAS CONNECTION SPECIFICATIONS 3/4” BSP female MAIN BURNER INJECTOR ORIFICE SIZE LPG 1.20 mm Natural 1.90 mm PILOT BURNER INJECTOR ORIFICE SIZE LPG 0.70 mm Natural 1.10 mm ELECTRICAL SUPPLY SPECIFICATION OPTIONS 230-240 V AC, 50 Hz, 2.1 A, 1P+N+E 220 V AC, 60Hz, 2.1 A, 1P+N+E ELECTRICAL PLUG SPECIFICATION REQUIREMENTS Australia AS 2124, 10 Amp, 3 pin New Zealand AS 2124, 10 Amp, 3 pin Other Countries Type to meet country standards WATER SUPPLY CONNECTION Max Pressure 550 kPa / 5.5 bar / 80 psi Min Pressure 100 kPa / 1.0 bar / 15 psi AUTOMATIC IGNITION CONTROL Lock-out condition after burner ignition failure. No re-ignition attempt. Units from S/N 205337: 1 re-ignition attempt in the event of flame loss during burner operation. Lock-out condition if re-ignition failure. NOTE: Refer to Appendix B for further ignition control specifications. Revision 4/F3576 © Moffat Ltd, December 2004 (button) -7 2. INSTALLATION WARNING: THIS APPLIANCE MUST BE GROUNDED. WARNING: ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY QUALIFIED PERSONS ONLY. 2. INSTALLATION WARNING: THIS APPLIANCE MUST BE GROUNDED. WARNING: ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY QUALIFIED PERSONS ONLY. This appliance must be installed in accordance with national installation codes and in accordance ...