Anleitung Elk Products, modell ELK-950
Hersteller: Elk Products Dateigröße: 32.97 kb Dateiname: e0d0994c-237d-4449-a08a-d58db923a54b.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
to 60 min. Power Products 1240 Battery, Lead Acid, 12v, 5Ah 1270 Battery, Lead Acid, 12v, 8Ah 12100 Battery, Lead Acid, 12v, 12Ah 12170 Battery, Lead Acid, 12v, 18Ah 12250 Battery, Lead Acid, 12v, 25Ah P112 12 Volts DC, 1 Amp Power Supply w/Enclosure P124 24 Volts DC, 800mA Power Supply w/Enclosure P1216 12 Volts DC, 1.5 Amp Power Supply P412 12 Volts DC, 4 Amp Power Supply P624 Power Supply & Battery Charger PD9 Power Distribution Module 965 Low Battery Cutoff and Power Switch TRG1640 Transformer, 16.5VAC @ 40 VA TRG2440 Transformer, 24VAC @ 40 VA Accessories 129 Computer Sound Card Interface 800 Audio Amplifier, 10 Watts 900-2 “B” Connectors,Unfilled,500 pcs 902-2 “B” Connectors,Gel filled,500 pcs 980 Telephone Line Fault Monitor 998 Warning Alarm System Decals 999 Double Sided Tape SL1 Strobe Light, 4 colors available WK1 Wall Mount Kit for SL1 Strobes For more information contact your local Distributor or: ELK PRODUCTS,INC 828-397-4200 FAX 828-397-4415 Email: info@elkproducts.com05/02 Telephone & Power Line Surge Suppressor ELK-950 APPLICATION: The ELK-950 Telephone and Power Line Surge Suppressor is specially designed to protect residential and commercial electronic security control equipment from damaging transients on the Power input line, the telephone line, and serves as the RJ-31/38X telephone connection block. Telephone & Power Line Surge Suppressor ELK-950 FEATURES: • Utilizes Solid State Surge Suppression. • Protects Incoming Telephone Line. • Protects AC Input From Transformer. • Clamps Line-To-Line & Line-To-Ground. • Self-Restores After Surges Within Rating. • RJ31/38X 8 Position Modular Jack. • Rugged, Easy To Mount Plastic Case. • Packed In Reusable Poly Storage Box. • Lifetime Limited Warranty. SPECIFICATIONS: • Response Time: < 1 Nanosecond. • Breakover Voltage: Telephone Line: 300 Volts. AC Power Line: 50 Volts. • Peak Pulse Current: Telephone Line: 100 Amps. AC Power Line: 50 Amps. • Ground Wire: 24" - 14 Gauge Stranded. This device complies with Part 68 of the FCC rules. FCC Reg. No. 5K6USA-23140-XP-N Ren No. 0.0B. Features and Specifications subject to change without notice. 828-397-4200 Voice 828-397-4415 Fax email: info@elkproducts.com PO Box 100 • Hwy. 70W • Hildebran, NC 28637 • USA Instructions Printed On Inside CONNECTIONS EARTH This terminal must be connected to a good quality earth ground using a 14-16 gauge wire. The best choice of GROUND ground is : Copper or galvanized ground rod (6' or longer) driven into the ground OR a copper cold water pipe. Do not use PVC pipe! An acceptable but less preferred ground is the screw on an electrical outlet. TELCO RING -Connect one side of the Incoming Telephone Line pair. (Commonly colored RED) TIP -Connect the other side of the Incoming Telephone Line pair. (Commonly colored GREEN) HOUSE R1 -Connect one side of the pair returning to the House Phone(s). (Commonly colored BLACK) T1 -Connect the other side of the pair returning to the House Phone(s). (Commonly colored YELLOW) J1 - 8 PIN Connect an 8 wire modular telephone cord from J1 to the Digital Communicator. Studies have found that the MODULAR cord should be at least 3 feet long for best surge suppression. The pin assignments of J1 are: 4 & 5 are RING JACK and TIP going to the control. 1 & 8 are R1 and T1 returning from the control. 2 & 7 are shorted together by jumper EOL, creating a closed circuit tamper loop to supervise the modular plug. This loop may be converted to a resistored EOL circuit by cutting the jumper and attaching the required resistor in series with the jumper. POWER Optional! Provides transient/surge suppression for the low voltage transformer power line input to the control. (DATA) CAUTION: UNPLUG TRANSFORMER UNTIL ALL CONNECTIONS ARE COMPLETE! IN (A & B) -Connect the two wires coming from the Transformer. Max. input is 24 volts AC. OUT (A & B) -Connect the two wires going to the Control. Polarity is not important with the AC. NOTE: The POWER terminals may alternately be used for surge protecting data transmission wires such as a keypad or zone expansion bus, as long as any measurable voltage on the two data wires is less than 24 volts. Connect the data wires to the IN and OUT terminals while observing polarity using the A & B markings. Jumper EOL shorts pins 2 & 7 for tamper supervision of the plug. AC Transformer 24 vac Max TEST SET R1 T1 Tip Ring HOUSE TELCO Incoming Telephone Line House Phone(s)Earth Ground Rod To Transformer Input On Control Panel Eight (8) Wire Modular Cord Min. 3 Ft. Long Connect to 24hr loop for Tamper Not Used To Digital Communicator Inputs On Control Panel J1 -EOL- ELK-950e TELEPHONE AND POWER LINE SURGE SUPPRESSOR WITH RJ31/ 38X JACK Convenient points for connecting a telephone linemans testset A B A B EARTH OUT IN GROUND (TIP) GREEN (RING) RED (T1) BROWN (R1) GRAY ORANGE BLUE YELLOW BLACK POWER TELEPHONE Telephone Co. Demark Block TIP RING LIFETIME LIMITED WARRANTY Elk Products, Inc....