Anleitung American Power Conversion, modell 1609

Hersteller: American Power Conversion
Dateigröße: 629.3 kb
Dateiname: ASTE-6Z8LQB_R0_EN.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The DIN rail kit is not included. When mounting on the back panel of an enclosure, select screws that are appropriate for the weight of this unit and the mounting surface material. Six screws must be used when mounting this unit in an enclosure. Three screws in the top of the bracket and three screws in the bottom of the bracket. Failure to follow these instructions may result in damage to the unit. Battery Installation The UPS battery is shipped in a separate carton. Refer to the installation guide included with the replacement battery for installation instructions. Top Bracket Bottom Bracket 4 Front Panel Connect Power and Equipment to the UPS Hardwiring should be performed by a qualified electrician. Use appropriate size wires. 1. The UPS features a transient voltage surge-suppression (TVSS) screw located on the front panel. The TVSS screw is used for connecting the ground lead on surge suppression devices such as telephone and network line protectors. Prior to connecting the grounding cable, ensure that the UPS is NOT connected to utility or battery power. 2. Hardwire the UPS. – In 230 V applications the UPS must be protected with a circuit breaker that complies with European standards for branch rated protection per the country of installation. – In 208 V applications, the 1609-U500E must be protected by a dual pole, 10 A branch rated circuit breaker with UL489 rating. – The 120 V 1609-U500N has supplementary circuit breaker protection. The unit should be protected by a single pole, 15 A branch rated circuit breaker with a UL489 rating. Allen-Bradley part number 1492-MCAA115 is suggested. Ensure that the branch circuit breaker is off prior to wiring the unit. 3. Connect equipment to the UPS. 4. Add optional accessories to the SmartSlot located on the front panel. 5. Turn on all connected equipment. To use the UPS as a master on/off switch, be sure all connected equipment is switched on. 6. Press the button on the front panel to start the UPS. – The battery charges to 90% capacity during the first four hours of normal operation. – Do not expect full battery run capability during this initial charge period. 7. For optimal computer system security, install PowerChute. monitoring software included with the UPS. PUSH TO RESET 1 EPO 2 EPO COM 3 NC 4 COM 5 NO 6 NC 7 COM 8 NO LOW BATTERY ON BATTERY INPUT 208/220-240V~ 50/60Hz, 7A MAX OUTPUT 23 325W, 2.7A MAX 0V~ 50/60Hz, 500VA N L N L GROUND NEUTRAL LINE GROUND NEUTRAL LINE Test 120 V model depicted. INPUT L2/N L1 OUTPUT L2/N L1 INPUT N L OUTPUT NEUTRAL LINE NEUTRAL LINE N L 208/230 V models 120 V models Connectors Communication Port A standard serial interface cable is incompatible with the UPS. SERIAL PORT Use the cable supplied with the unit. Contact Closure Port The relays are connected from the common (COM) to the normally 8 NO ON closed (NC) pins.When the unit enters a low battery or on battery state, 7 COM BATTERY the appropriate relay will transition and connect the common (COM) to 6 NC 5 NO LOW the normally open (NO) pin. 4 COM BATTERY 3 NC The Contact Closure Port connection will automatically disable when a 2 EPO COM Network Management Card or the Serial Port connection are used. 1 EPO Output Contact Ratings: Parameter Value nominal switching capacity 1 A @ 30 VDC maximum switching power 30 W maximum switching voltage 60 VDC maximum switching current 2 ADC maximum carrying current 2 ADC surge ratings 2 kV per Bellcore TA-NWT-001089 1.5 kV per FCC part 68 Emergency Power Off The emergency power off (EPO) feature is user configurable. EPO provides immediate de-energizing of connected equipment from a remote location, without switching to battery operation. Use a normally-open contact to connect the EPO COM terminal to the EPO terminal. The EPO interface is a Safety Extra Low Voltage (SELV) circuit. Connect it only to other SELVcircuits. The EPO interface monitors circuits that have no determined voltage potential. Such closure circuits may be provided by a switch or relay properly isolated from the utility. To avoid damage to the UPS, do not connect the EPO interface to any circuit other than a closure type circuit. Use one of the following cable types to connect the UPS to the EPO switch. • CL2: Class 2 cable for general use. • CL2P: Plenum cable for use in ducts, plenums, and other spaces used for environmental air. • CL2R: Riser cable for use in a vertical run in a floor-to-floor shaft. • CLEX: Limited use cable for use in dwellings and for use in raceways. • For installation in Canada: Use only CSA certified, type ELC (extra-low voltage control cable). • For installation in other countries: Use standard low-voltage cable in accordance with national and local regulations. Operation Operation UPS Display Panel 120 V 208/230 V models models INPUT 208/220-240V~ 50/60Hz, 7A MAX OUTPUT 23 325W, 2.7A MAX0V~ 50/60Hz, 500VA LN LN LINE NEUTRAL GROUND LINE NEUTRAL GROUND Test INPUT 208/220-240V~ 50/60Hz, 7A MAX OUTPUT 23 325W, 2.7A MAX0V~ 50/60Hz, 500VA L1L2...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien