Anleitung American Power Conversion, modell 208VAC

Hersteller: American Power Conversion
Dateigröße: 1.39 mb
Dateiname: ASTE-6Z8LG6_R0_EN.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The UPS provides continuous power from its internal battery until the utility line returns to safe levels or the battery is discharged. 1: INSTALLATION Read the Safety Instruction sheet before installing the UPS. Unpacking Inspect the UPS upon receipt. Notify the carrier if there is damage. The packaging is recyclable; save it for reuse or dispose of it properly. Check the package contents. The package contains the UPS, four battery packs, rail kit, and a litera ture kit containing cable(s), and product documentation. The UPS is shipped with the battery disconnected. Positioning the UPS The UPS is heavy. Select a location sturdy enough to handle the weight. Do not operate the UPS where there is excessive dust or the temperature and humidity are outside the specified limits. PLACEMENT 0° - 40°C (32°-104°F) 0-95% Relative 2.5 cm (1in) Humidity A qualified or licensed electrician must install the UPS. 1 Mounting the UPS in the Rack Due to the weight of the UPS, two people are required for mounting. Battery installation is to follow. Brackets Cleats Hardwire the Electrical Connection (230V Models Only) Verify that the supply line contains a 25 Amp circuit breaker BEFORE hardwiring the UPS. Batteries are installed in the UPS upon hardwiring completion. Incorporate an easy access disconnect device in the fixed wiring design. Wire Input Plate 1. Select the appropriate wire size and connectors. For most applications, #10 AWG (5 sq. mm) wire should be sufficient. 2. Remove screw and access door. 3. Slide the wire input plate to the left and remove. Access Door 4. Detach circular knockout and feed the wire cable through this opening. Using a threaded lock nut, fasten the plate to the cable or conduit connectors. 5. Connect the wires to the terminal block inside the UPS. Loosen the screw, then feed the copper wire into the terminal block and tighten the screw. Connect the protective earth ground to the terminal block at the position marked with the ground symbol ( ). The UPS wiring color code is: GREEN for GROUND WHITE for NEUTRAL BLACK for HOT 6. Replace the wire input plate. 7. Inspect the connections and location of the excess wires before installing the access door. 8. Replace the access door (removed in step 2). Installing the Batteries Step 1 Step A Step B Step 2 Connectors inside UPS Gray Connector A: Plug gray connector on each battery pack into con- nectors inside the UPS. B: Tuck the white cord, which serves as a handle for the connector, to the side. 2 Connecting Equipment and Power to the UPS SMART-UPS REAR PANEL 1. Connect equipment to the UPS. 2. Add any optional accessories to the Smart-Slot. The UPS is shipped with the APC Network Management card pre-installed. Refer to 208V 230 Volt the documentation in the literature kit and/or CD-ROM provided. 3. 208V Models Only: Using a power cord, plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords and adaptor plugs. 4. Turn on all connected equipment. To use the UPS as a master ON/OFF switch, be sure all connected equipment is switched ON. The equipment will not be powered until the UPS is turned on. 5. To power up the UPS press the button on the front panel. • The UPS charges its battery when it is connected to utility power. The battery charges to 90% capacity during the first three hours of normal operation. Do not expect full battery run capability during this initial charge period. 6. For additional computer system security, install PowerChutePlus® Smart-UPS monitoring software. It provides automatic shutdown capabilities on most major network operating systems. See APC website, for other available accessories. BASIC CONNECTORS Serial Port Power management software and interface kits can be used with the UPS. Use only interface kits supplied or approved by APC. Use the APC supplied cable to connect to the Serial Port. DO NOT use a standard serial interface cable since it is incompatible with the UPS connector. Battery See the APC web site, for the correct external battery Connector pack model number for your UPS. TVSS Screw The UPS features a transient voltage surge-suppression (TVSS) screw for connecting the ground lead on surge suppression devices such as telephone and network line protectors. When connecting grounding cable, disconnect the unit from the utility power outlet. 3 2: OPERATION INDICATORS AND CONTROLS ON THE SMART-UPS SMART-UPS FRONT PANEL Power On Power Off Load Battery Charge Online The online LED illuminates when the UPS is supplying utility power to the connected equipment. AVR Trim This LED illuminates to indicate the UPS is compensating for a high utility voltage. AVR Boost This LED illuminates to indicate the UPS is compensating for a low utility voltage. On Battery When the on battery power LED is illuminated the UPS is supplying battery power to the connected equipment. The LED illuminates and the UPS emits a sustained alarm tone when an overload condition o...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien