Anleitung Zusammenfassung


THE REPLACE BATTERY/BATTERY DISCONNECTED LED IS ILLUMINATED This LED flashes and a short beep is emitted every two seconds to indicate the battery is disconnected. Check that the battery connector is fully engaged. Weak battery. Allow the battery to recharge for 24 hours. Then, perform a self-test. If the problem persists after recharging, replace the battery. Failure of a battery self-test. The UPS emits short beeps for one minute and the replace battery LED illuminates. The UPS repeats the alarm every five hours. Perform the self- test procedure after the battery has charged for 24 hours to confirm the replace battery condition. The alarm stops and the LED clears if the battery passes the self-test. THE SITE WIRING FAULT LED ON THE REAR PANEL IS ILLUMINATED The UPS is plugged into an improperly wired utility power outlet. Wiring faults detected include missing ground, hot-neutral polarity reversal, and overloaded neutral circuit. Contact a qualified electrician to correct the building wiring. THE INPUT CIRCUIT BREAKER HAS TRIPPED The UPS is overloaded. The plunger on the circuit breaker has popped out. Reduce the load on the UPS by unplugging equipment. Press in the plunger on the circuit breaker. UPS OPERATES ON BATTERY ALTHOUGH UTILITY VOLTAGE EXISTS The UPS input circuit breaker has tripped. To reduce the load on the UPS, unplug equipment and press in the plunger on the circuit breaker. The line voltage is very high, low or distorted. Move the UPS to a different outlet on a different circuit, as inexpensive fuel powered generators may distort the voltage. If acceptable to the connected equipment, reduce the UPS sensitivity (see User Configurable Items). ON-LINE LED There is no illumination. The UPS is running on battery, or it must be turned on. The LED is blinking. The UPS is running an internal self-test. 11 Shipping and Service Prepare the UPS for shipping: Shutdown and disconnect any equipment attached to the UPS. Shut down the UPS, and disconnect the UPS from the utility power outlet. Disconnect the battery. If the UPS requires service do not return it to the dealer. Follow these steps: 1. Review the problems discussed in Troubleshooting to eliminate common problems. 2. If the problem persists, contact APC Customer Service through the APC web site, • Note the model number of the UPS, the serial number, and the date purchased. If you call APC Customer Service, a technician will ask you to describe the problem and attempt to solve it over the phone. If this is not possible, the technician will issue a Returned Material Authorization Number (RMA#). • If the UPS is under warranty, repairs are free. 3. Pack the UPS in its original packaging. If this is not available, refer to for information about obtaining a new set. • Pack the UPS properly to avoid damage in transit. Never use Styrofoam beads for packaging. Damage sustained in transit is not covered under warranty. • Always DISCONNECT THE BATTERY before shipping in compliance with U.S. Department of Transportation (DOT), and IATA regulations. The battery module(s) may remain in the UPS; it does not have to be removed. 4. Mark the RMA# on the outside of the package. 5. Return the UPS by insured, prepaid carrier to the address given to you by Customer Service. Contact Information U.S. Customers - Refer to International Customers - Refer to select the appropriate country from the country selection field, and select the Support tab at the top of the web page. 12 7: REGULATORY AND WARRANTY INFORMATION Regulatory Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense. Shielded signal cables must be used with this product to ensure compliance with the Class A FCC limits. Limited Warranty American Power Conversion (APC) warrants this product to be free from defects in materials and workmanship for a period of three years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support. Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien