Anleitung American Power Conversion, modell 110 Vac

Hersteller: American Power Conversion
Dateigröße: 331.46 kb
Dateiname: ASTE-6Z8LUF_R1_EN.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:
Netzteile - 110 Vac (280.31 kb)en

Anleitung Zusammenfassung


During the self-test, the UPS briefly operates the connected equipment on battery. Manual: Press and hold the button for a few seconds to initiate the self-test. Cold Start To supply battery power to the UPS and connected equipment in the absence of utility voltage (see Troubleshooting), press the front display panel button for one second and release. The UPS will beep briefly and go quiet. Press and hold the button again, but for approximately three seconds. The unit will emit a sustained beep. Release the button during this beep. 6 4: USER CONFIGURABLE ITEMS NOTE: SETTINGS ARE ADJUSTED THROUGH POWERCHUTE SOFTWARE FUNCTION FACTORY DEFAULT USER SELECTABLE CHOICES DESCRIPTION Automatic Self-Test Every 14 days (336 hours) Every 7 days (168 hours), Every 14 days (336 hours), On Startup Only, No Self-Test Set the interval at which the UPS will execute a self-test. UPS ID UPS_IDEN Up to eight characters (alphanumeric) Uniquely identify the UPS, (i.e. server name or location) for network management purposes. Date of Last Battery Replacement Manufacture Date mm/dd/yy Reset this date when you replace the battery module. Minimum Capacity Before Return from Shutdown 0 percent 0, 15, 50, 90 percent Specify the percentage to which batteries will be charged following a low- battery shutdown before powering connected equipment. Voltage Sensitivity The UPS detects and reacts to line voltage distortions by transferring to battery operation to protect connected equipment. High High sensitivity, Medium sensitivity, Low sensitivity Note: In situations of poor power quality, the UPS may frequently transfer to battery operation. If the connected equipment can operate normally under such conditions, reduce the sensitivity setting to conserve battery capacity and service life. Alarm Delay After Line Fail 5 seconds 5 second delay, 30 second delay, At low battery condition, No alarm Set the delay to avoid alarms for minor power glitches. Shutdown Delay 60 seconds 60, 180, 300, 600 seconds Set the interval between the time when the UPS receives a shutdown command and the actual shutdown. 7 NOTE: SETTINGS ARE ADJUSTED THROUGH POWERCHUTE SOFTWARE FUNCTION FACTORY DEFAULT USER SELECTABLE CHOICES DESCRIPTION Low Battery 2 minutes 2, 5, 7, 10 minutes The UPS will beep when 2 minutes of Warning PowerChute (Times are approxibattery runtime remains. Business Edition mate.) Change the low battery warning inter- software provides val setting to the time that the operatautomatic, unating system or system software requires tended shutdown to safely shut down. when approximately 2 minutes of battery operated runtime remains. Synchronized 0 seconds 0, 60, 180, 300 Specify the time the UPS will wait Turn-on Delay seconds after the return of utility power before turn-on (to avoid branch circuit overload). High Transfer 110/120 V model: 110/120 V model: Set the high transfer point higher to Point 127 Vac 127, 130, 133, 136 avoid unnecessary battery usage when Vac the utility voltage is usually high and 230 V model: 253 Vac 230 V model: 253, 257, 261, 265 Vac the connected equipment is specified to operate with input voltages this high. Low Transfer Point 110/120 V model: 110/120 V model: Set the low transfer point lower when 106 Vac 97, 100, 103, 106 Vac the utility voltage is usually low and the connected equipment is specified 230 V model: 230 V model: to operate with input voltages this low. 208 Vac 196, 200, 204, 208 Vac 8 5: STORAGE AND MAINTENANCE Storage Store the UPS covered in a cool, dry location, with the battery fully charged. At -15 to +30 °C (+5 to +86 °F), charge the UPS battery every six months. At +30 to +45 °C (+86 to +113 °F), charge the UPS battery every three months. Battery Replacement The UPS battery life differs based on usage and environment. Consider replacing the battery every three years. This UPS has an easy to replace, hot-swappable battery. Replacement is a safe procedure, isolated from electrical hazards. You may leave the UPS and connected equipment on during the replacement procedure. See your dealer or contact APC (see Contact Information) for information on replacement batteries. Note: Upon battery disconnection, equipment is not protected from power outages. For battery replacement instruction, refer to applicable steps in Rack-Mounting. Be sure to deliver the spent battery to a recycling facility or ship it to APC in the replacement battery packing material. 9 6: TROUBLESHOOTING, SHIPPING, AND SERVICE Use the chart below to solve minor UPS installation and operation problems. Refer to with complex UPS problems, and for battery runtime charts. PROBLEM AND/OR POSSIBLE CAUSE SOLUTION UPS WILL NOT TURN ON UPS not connected to utility power supply. Check that the power cord from the UPS to the utility power supply is securely connected at both ends. Battery not connected properly. Check that battery connector is engaged. Very low or no utility voltage. Check the utility power supply to the UPS by plugging...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien