Login:
Stimmen - 1, Durchschnittliche Bewertung: 5 ( )

Anleitung American Power Conversion, modell Powerware Uninterruptible Power System Prestige Series

Hersteller: American Power Conversion
Dateigröße: 1.13 mb
Dateiname: 3c330ae5-fc17-4a43-8ada-fe59eca3fb09.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Powerware® Prestige Series Installation and Operator’s Manual for IBM Applications (3000 VA) Uncontrolled Copy CHAPTER 3 INSTALLATION The following sections describe UPS storage requirements and the installation and startup of the UPS. Unpacking and Inspection Carefully unpack the UPS and battery cabinets, making sure to retain the packaging materials. Examine each unit carefully for any signs of damage and immediately notify your distributor if damage is present. For assistance with the IBM 9910 UPS, see Chapter 8, “AS/400 Service” on page 75. UPS and Battery Cabinet Storage If you plan to store the UPS or battery cabinets prior to use, store them in a cool, dry environment. Storage temperature should not exceed 35.C(95.F) in orderto preserve battery life. Forlongerterm storage, energize the UPS and battery cabinet for approximately 8 hours every 90 days in order to maintain battery charge. Whenever the units are not energized, verify the circuit breaker on all battery cabinets is returned to the OFF (O) position. UPS with PowerPass Distribution Module Installation The PPDM is a standard option for the AS/400 systems. The PPDM has a Maintenance Bypass feature that supplies power to your equipment even when the UPS electronics are removed for maintenance or upgrades. There are three PPDM models available: the 5-15R PPDM, the 5-15R/6-15R PPDM, and the IEC 320-C13 PPDM. The rear panels of these models are shown in Figure 5 on page 37, Figure 6 on page 38, and Figure 8 on page 41, respectively. Powerware® Prestige Series Installation and Operator’s Manual for IBM Applications (3000 VA) Uncontrolled Copy Installation 36 Powerware® Prestige Series Installation and Operator’s Manual for IBM Applications (3000 VA) Uncontrolled Copy Use the following procedure to install the UPS and battery cabinets with the PPDM: 1. Place the UPS near the equipment to be protected. The UPS should be well ventilated and away from direct sunlight or other heat source. Place the UPS and battery cabinets on top of or beside the PPDM as shown in Figure 4. NOTE You can install additional battery cabinets while the UPS is operating, but confirm the UPS is not in Battery mode (see page 49). Battery Cabinet UPS Cabinet Battery Cabinet UPS Cabinet PPDM* PPDM Air Vents *NOTE: The IEC 320-C13 PPDM should be placed on top of the UPS cabinet. Figure 4. Cabinet Setup 2. Verify the circuit breaker on all battery cabinets is in the OFF (O) position. 3. Remove the battery connector guard. Plug the battery cord into the external battery connector on the UPS. All battery connectors are polarized to prevent incorrect connection. 4. If additional battery cabinets are to be used, plug the battery cord of the second cabinet into the external battery connector of the first battery cabinet. Follow this procedure for each additional battery cabinet. 5. Remove the breaker tie from the circuit breaker on all battery cabinets. 6. Switch the circuit breaker on all battery cabinets to the ON ( | ) position. Installation Powerware® Prestige Series Installation and Operator’s Manual for IBM Applications (3000 VA) Uncontrolled Copy 37 PPDM Power Output Receptacles (5-15R) Utility Input Connector UPS Cabinet Breaker Tie Circuit Breaker Battery Cabinet External Battery Connector Battery Cord Bypass Switch Load Circuit Protectors Input Circuit Protector Battery Connector Power Output Receptacle Power Input Connector Serial Port REPO Receptacle (Optional) Y-Cord Tie Wrap Mounts Figure 5. UPS with 5-15R PPDM Rear Panel Installation 38 Powerware® Prestige Series Installation and Operator’s Manual for IBM Applications (3000 VA) Uncontrolled Copy PPDM Neutral Ground Screw Utility Input Connector (IEC 320-C13) UPS Cabinet Breaker Tie Circuit Breaker Battery Cabinet External Battery Connector Battery Cord Bypass Switch Output Protectors Input Circuit Protector Battery Connector Power Output Receptacle Power Input Connector Serial Port REPO Receptacle (Optional) Y-Cord Power Output Receptacles (5-15R and 6-15R) Power Output Receptacle (IEC 320-C19) Tie Wrap Mounts Figure 6. UPS with 5-15R/6-15R PPDM Rear Panel 7. For 5-15R/6-15R PPDM Models Only: The factory default for the PPDM output neutral is grounded. In some countries, the output neutral should not be grounded. If your application requires an ungrounded output neutral, continue with Step 7; otherwise, skip to Step 8. Installation For ungrounded output neutral applications only. Remove the ground screw, rotate the ground cover until it snaps into place, and reinstall the ground screw in the ungrounded position (see Figure 7). Neutral Ground Screw Ground Cover Neutral Ground Screw Ground Cover Grounded Position Ungrounded Position (Default) (For certain applications only) Figure 7. Output Neutral Ground Screw 8. Two tie wraps are included with the UPS to secure the Y-cord to the input and output receptacles on the UPS rear panel. Insert the tie wrap through the slot on each tie wrap mount. 9. Verify the Bypass switch on t...

Dieses Handbuch ist für folgende Modelle:
Netzteile - Powerware Uninterruptible Power System Prestige Series (1.13 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien