Anleitung Zusammenfassung


Push button switches allow the display to alternately show the programmed values of voltage and current or the overvoltage limit. LED indicators show the operating state of the unit (CV, CC, Unregulated and Overvoltage). All connections are made to rear-panel screw-on terminals. Output voltage can be locally or remotely sensed. A six-position MODE switch located on the rear panel is used to change from front panel control to remote voltage or remote resistance control. See section 3 for a description of remote programming, remote sensing and several methods of multiple supply operation. Either the positive or negative output terminal may be grounded or the output may be floated (including output voltage) up to ± 240 Vdc on models 6011A, 6012B, 6023A and 6028A or ± 550 Vdc on models 6010A and 6015A from chassis ground. The power supply is fan cooled and is packaged in an Agilent Technologies System II-compatible modular that provides easy access for servicing. A thermostat shuts down the supply if an over-temperature condition occurs and resets automatically. Safety Considerations This product is a Safety Class 1 instrument (provided with a protective earth terminal). The instrument and this manual should be reviewed for safety markings and instructions before operation. Refer to the Safety Summary page at the beginning of this manual for general safety information. Safety information for specific procedures is located at appropriate places in this manual. Options Options are standard factory modifications or accessories that are delivered with the supply. The following options are available. Note lower output power and voltage specifications for Option 100, which is described in Appendix A. General Information 9 Option Description 100 Input power: 100 Vac + 6%, -10%; 48-63 Hz single phase. 120 Input power: 120 Vac +6%, -13%. 48-63 Hz single phase. 220 Input Power: 220 Vac +6%, -13%; 48-63 Hz, single phase. 240 Input power: 240 Vac +6%, -13%; 48-63 Hz, single phase. 800 Rack mount kit for two units side by side (models 6023A and 6028A only) 908 Rack mounting kit 909 Flanges with Handles 0L2 One additional User’s Guide 0B3 Service Manual Accessories The System-II cabinet accessories listed below may be ordered with the power supply or separately from your local Agilent Technologies Sales and Support Office (see list of addresses at rear of this manual). For Agilent Models 6023A and 6028A Agilent Part No Description 5062-3989 Front handle kit for 5-1/4 inch high cabinets 1460-1345 Tilt stand (1) snaps into standard foot on; must be used in pairs 5062-3977 Rack flange kit for 5-1/4 inch high cabinet (will be shipped with supply if ordered as Option 908) 5062-3983 Rack mount flange kit with handles 1494-0060 Rack slide kit, non tilting 5060-2865 Service kit, includes extenders for control and power mesh boards, three cables to allow GP-IB and PSI boards to lie on table outside unit, and control board test connector. 5060-2866 FET service kit. Includes FETs and all components that should be replaced with FETs. 59510A Relay Accessory 59511A Relay Accessory (Polarity Reversing) For Agilent Models 6023A and 6028A For Agilent Models 6023A and 6028A Agilent Part No Description 5062-3960 Rack mounting adapter kit for side mounting one 7-inch high cabinet, includes one rack flange and one half-module width extension adapter. (Will be shipped with instrument if ordered as Option 908). This rack mounting adapter kit is not compatible with front handle kit Agilent P/N 5061-3990). 5062-3961 Rack mounting adapter kit for center mounting one 7-inch high cabinet, includes one rack flange and one quarter-module width extension adapter (two kits required), there will be surplus of hardware. 5062-3978 Rack flange kit for 7-inch high cabinet. Must be used with another half-module width unit of equal depth with lock link kit 5061-9694. (Will be shipped if instrument is ordered as Option 800). 5061-9694 Lock link kit for joining units of equal depth, contains hardware for three side-by-side joints (four units) and two over-under joints (three units). Locking cabinets together horizontally in a configuration wider than one full module is not recommended. 5062-3978 and 5061-9694 will be shipped if Option 800 is ordered. 5062-3990 Front handle kit for 7-inch high cabinets. Corresponding flange kit is 5061-2072. This front handle kit is not compatible with rack mounting adapter kit (Agilent PIN 5062-3960) or Option 908. 5061-2072 Flange kit to be used with front handle kit 5062-3990. 5062-3984 Rack mounting flange kit with handles for 7-inch high cabinet. Must be used with another half-module width unit of equal depth with lock link kit 5061-9694. 5062-4003 Bail handle kit for carrying 7-inch high, half-module width cabinet. 1460-1345 Tilt stand (1) snaps into standard foot on instrument, must be used in pairs. 5062-3998 Support shelf bit for mounting on or more 7-inch high cabinets of any depth to 20 inches. 5062-4027 Front filler pane...

Dieses Handbuch ist für folgende Modelle:
Netzteile - 6010A (282.1 kb)
Netzteile - 6012B (282.1 kb)
Netzteile - 6015A (282.1 kb)
Netzteile - 6023A, 6028A (282.1 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien