Login:
Stimmen - 5, Durchschnittliche Bewertung: 4.6 ( )

Anleitung Agilent Technologies, modell E3614A

Hersteller: Agilent Technologies
Dateigröße: 1.53 mb
Dateiname: AgilentE361516AManual.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Agilent Technologies assumes no liability for the customer's failure to comply with these requirements. SAFETY SYMBOLS BEFORE APPLYING POWER. Verify that the product is set to match the available line voltage ! Instruction manual symbol; the product will and that the correct fuse is installed. be marked with this symbol when it is necessary for the user to refer to the instruction GROUND THE INSTRUMENT. manual. This product is a Safety Class I instrument (provided with a protective earth terminal). To minimize shock hazard, the instrument chassis and cabinet must be connected to an electrical ground. or Indicate earth(ground) terminal. The instrument must be connected to the ac power supply mains through a three-conductor power cable, with the third wire firmly connected to an electrical ground(safety ground) at the power The WARNING sign denotes a hazard. It outlet. Any interruption of the protective(grounding) conductor or calls attention to a procedure, practice, disconnection of the protective earth terminal will cause a poten or the like, which, if not correctly performed or WARNING tial shock hazard that could result in personal injury. If the instru adhered to, could result inpersonal injury. Do ment is to be energized via an external autotransformer for not proceed beyond a WARNING sign until voltage reduction, be certain that the autotransformer common the indicated conditions are fully understood terminal is connected to the neutral(earthed pole) of the ac power and met. lines (supply mains). DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE. The CAUTION sign denotes a hazard. It calls Do not operate the instrument in the presence of flammable attention to an operating procedure, or the like, which, if not correctly performed or gases or fumes. CAUTION adhered to, could result in damage to or destruction of part or all of the product. Do KEEP AWAY FROM LIVE CIRCUITS. not proceed beyond CAUTION sign until the Operating personnel must not remove instrument covers. Compo indicated conditions are fully understood and nent replacement and internal adjustments must be made by met. qualified service personnel. Do not replace components with power cable connected. Under certain conditions, dangerous voltages may exist even with the power cable removed. To avoid inju-The NOTE sign denotes important inforries, always disconnect power, discharge circuits and remove mation. It calls attention to a procedure, pracexternal voltage sources before touching components. tice, condition or the like, which is essential to highlight. NOTE DO NOT SERVICE OR ADJUST ALONE. Do not attempt internal service or adjustment unless another per son, capable of rendering first aid and resuscitation, is present. DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT. Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the instrument. Return the instrument to a Agilent Technologies Sales and Service Office for service and repair to ensure that safety features are maintained. Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel. 1-2 Table of Contents SAFETY SUMMARY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 GENERAL INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 SAFETY REQUIREMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 INSTRUMENT AND MANUAL IDENTIFICATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 OPTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 ACCESSORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 INSTALLATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 INITIAL INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 Mechanical Check....

Dieses Handbuch ist für folgende Modelle:
Netzteile - E3615A (1.53 mb)
Netzteile - E3616A (1.53 mb)
Netzteile - E3617A (1.53 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien