Anleitung Zusammenfassung


Repairs to the machine may only be made by a qualified service technician, according to the manufacturer's specifications. After repairs are completed, the operator must perform a pre-operation inspection again before going on to the function tests. Scheduled maintenance inspections shall be performed by qualified service technicians, according to the manufacturer's specifications and the requirements listed in the responsibilities manual. PartNo.48643 Genie IWP Super Series Operator’s Manual Second Edition • Fourth Printing PRE-OPERATION INSPECTION Pre-operation Inspection . Be sure that the operator's, safety and responsibilities manuals are complete, legible and in the storage container located on the mast. . Be sure that all decals are legible and in place. See Decals section. . AC & DC models: Check for hydraulic oil leaks and proper oil level. Add oil if needed. See Maintenance section. . DC models: Check for battery fluid leaks and proper fluid level. Add distilled water if needed. See Maintenance section. Check the following components or areas for damage, modifications and improperly installed or missing parts: . Electrical components, wiring and electrical cables . Hydraulic power unit, hoses, fittings and cylinders . Hydraulic manifolds and foot pump . Platform entry mid-rail or gate . Sequencing cables and pulleys . Lifting chains and idler wheels . Mast columns and counterweight . Nuts, bolts and other fasteners . Breather cap . Foot pads . Adjustable glide pads If equipped: Power wheel assist option . Steer handle . Hydraulic motor and hoses If equipped: IWP-20S with Outreach option . Locking bracket . Handle and handle lock . Extension arms . Confirm proper counterweight configuration (part number is stamped on top of counterweight) ANSI & CE Indoor Front P/N Rear P/N IWP-20S Standard Base 37354 37355 IWP-20S Wide Base 40990 40991 CSA Front P/N Rear P/N IWP-20S Wide Base 40988 40989 Check entire machine for: . Dents or damage . Corrosion or oxidation . Cracks in welds or structural components . Inspect and clean battery terminals and all battery cable connections . Be sure that all structural and other critical components are present and all associated fasteners and pins are in place and properly tightened. Genie IWP Super Series PartNo.48643 Second Edition • Fourth Printing Operator’s Manual Observe and Obey: Only routine maintenance items specified in this manual shall be performed by the operator. Scheduled maintenance inspections shall be completed by qualified service technicians, according to the manufacturer's specifications and the requirements specified in the responsibilities manual. Maintenance Symbols Legend The following symbols have been used in this manual to help communicate the intent of the instructions. When one or more of the symbols appear at the beginning of a maintenance procedure, it conveys the meaning below. Indicates that tools will be required to perform this procedure. Indicates that new parts will be required to perform this procedure. Maintenance Check the Battery - DC Models Proper battery condition is essential to good machine performance and operational safety. Improper fluid levels or damaged cables and connections can result in engine component damage and hazardous conditions. Electrocution hazard. Contact with hot or live circuits could result in death or serious injury. Remove all rings, watches and other jewelry. Bodily injury hazard. Batteries contain acid. Avoid spilling or contacting battery acid. Neutralize battery acid spills with baking soda and water. Perform this test after fully charging the batteries. 1 Put on protective clothing and eye wear. 2 Remove the battery vent caps. 3 Check the battery acid level. If needed, replenish with distilled water to the bottom of the battery fill tube. Do not overfill. 4 Install the vent caps. PartNo.48643 Genie IWP Super Series Operator’s Manual Second Edition • Fourth Printing MAINTENANCE MAINTENANCEMAINTENANCE Check the Hydraulic Oil Level Maintaining the hydraulic oil at the proper level is essential to machine operation. Improper hydraulic oil levels can damage hydraulic components. Daily checks allow the inspector to identify changes in oil level that might indicate the presence of hydraulic system problems. 1 Be sure the platform is fully lowered. 2 Check the sight gauge on the side of the hydraulic tank. Result: The hydraulic oil level should be visible in the middle of the sight gauge. Do not overfill. Hydraulic oil specifications Hydraulic oil type Dexron equivalent Scheduled Maintenance Maintenance performed quarterly, annually and every two years must be completed by a person trained and qualified to perform maintenance on this machine according to the procedures found in the service manual for this machine. Machines that have been out of service for more than three months must receive the quarterly inspection before they are put back into service. Genie IWP Super Series PartNo.48643 Second Edition...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien