Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Heat & Glo LifeStyle, modell 8000TVLP-OAKIPI

Hersteller: Heat & Glo LifeStyle
Dateigröße: 2.4 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Flat to 6/12...........................................................1.0* Over 6/12 to 7/12.................................................1.25* Over 7/12 to 8/12.................................................1.5* Over 8/12 to 9/12.................................................2.0* Over 9/12 to 10/12...............................................2.5 Over 10/12 to 11/12.............................................3.25 Over 11/12 to 12/12.............................................4.0 Over 12/12 to 14/12.............................................5.0 Over 14/12 to 16/12.............................................6.0 Over 16/12 to 18/12.............................................7.0 Over 18/12 to 20/12.............................................7.5 Over 20/12 to 21/12.............................................8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Figure 6.3 Leveled Termination Caps B-VENT GAS, WOOD OR FUEL OIL TERMINATION A GAS TERMINATION B C Wood & Fuel Oil Termination Comments A 6 in. 20 in. min. Horizontal distance between terminations B 8 ft. 8 ft. min. Distance to perpendicular wall C 18 in. 18 in. Vertical distance between terminations Gas Termination B-VENT GAS, WOOD OR FUEL OIL TERMINATION 8 FT. (2.4 M) (MINIMUM) TO PERPENDICULAR WALL (GAS ONLY) WOOD OR GAS TERMINATION 20 IN. MIN. * (508 MM) * IF USING DECORATIVE CAP COVER(S), THIS DISTANCE MAY NEED TO BE INCREASED. REFER TO THE INSTALLATION INSTRUCTIONS SUPPLIED WITH THE DECORATIVE CAP COVER. Figure 6.2 Staggered Termination Caps Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. N • 11/08 7 77 Vent Information and Diagrams A. Vent Guidelines WARNING! Fire Risk/Asphyxiation! This appliance requires the specified pipe for operation. Incorrect pipe may cause spillage, condensation and overheating. These models require the following size B-vent double wall, or single wall rigid or flex vent pipe. Models Pipe Size 8000TV-OAK 6 inch • Follow pipe manufacturer’s installation guidelines when installing the appliance. WARNING! Fire Risk/Explosion/Asphyxiation! DO NOT connect this gas appliance to a chimney flue serving a separate solid-fuel or gas burning appliance. • Vent this appliance directly outside. • Use separate vent system for this appliance. May impair safe operation of this appliance or other appliances connected to the flue. B. Vent System Configuration CAUTION! Risk of Fire! ALL vent configuration specifications MUST be followed. This product is tested and listed to these specifications. Appliance performance will suffer if specifications are not followed. Rise to Run Ratio = 2:1 Maximum Total Horizontal Run = 15 Feet Minimum Total Vertical Rise = 9 Feet Maximum Total Vertical Rise = 30 Feet Maximum Number of Elbows: Two 90. or Four 45. Note: A rise of 1/4 inch per foot of horizontal run is required. WARNING! Risk of Fire or Explosion! Insulation and other combustibles must not infringe on clearances. • ALWAYS maintain specified clearances around venting and firestop systems. • Install firestops as specified. Failure to keep insulation or other material away from vent pipe may cause fire. Figure 7.1 METAL PLUMBER’S STRAP9 FEET MINIMUM VENT SUPPORTS ARE PER VENT MANUFACTURER’S SPECIFICATIONS MINIMUM CLEARANCES ARE PER VENT MANUFACTURER’S SPECIFICATIONS Note: Other vent components are noted in Figure 4.2 Figure 7.2 METAL PLUMBERS' STRAP MAXIMUM HORIZONTAL RUN IS 50% OF VERTICAL. HORIZONTAL RUN CANNOT BE MORE THAN 15 FT. VENT SUPPORTS ARE PER VENT MANUFACTURER'S SPECIFICATIONS. Note: Horizontal runs require 1/4 in. rise per foot run. Note: Other vent components are noted in Figure 4.2 Figure 7.3 45 DEGREES ELBOW 90 DEGREES ELBOW OFFSETS EXCEEDING 45 DEGREES ADAPT HORIZONTAL LIMITATIONS MAXIMUM HORIZONTAL 15 FEET MINIMUM VERTICAL 9 FEET Note: Maximum horizontal distance is 50% vertical vent height or up to 15 feet. Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. N • 11/08 8 88 Vent Clearances and Framing A. Pipe Clearances to Combustibles Vent clearances are per vent manufacturer’s specifications. MUST be Listed B-Vent pipe. WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling firestops • Between wall shield firestops • Around vent system Failure to keep insulation or other material away from vent pipe may cause over heating and fire. B. Wall and Ceiling Penetration Framing For a wall or ceiling penetration consult B-vent pipe manufacturer’s instructions to provide adequate clearances. Use same size framing materials as those used in the wall or ceiling construction. Firestop spacers must be used in wall and ceiling penetrations per the B-Vent pipe manufacturer’s specifications and national, regional and local codes. Note: MUST terminate vertically. C. Vertical Penetration Framing WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent....

Dieses Handbuch ist für folgende Modelle:
Gas Heizthermen - 8000TV-OAK (2.4 mb)
Gas Heizthermen - 8000TV-OAK-IPI (2.4 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien