Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly into fireplace. Do not place a blower inside the burner area of the firebox. Ceiling fans may create drafts that alter flame patterns. Sooting and improper burning will result. During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful, but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence. The initial break-in operation should last 2-3 hours with the burner at the highest setting. Provide maximum ventilation by opening windows or doors to allow odors to dissipate. Any odors remaining after this initial break-in will be slight and will disappear with continued use. Millivolt Valve for VFDR Series Figure 17 VALVE PRESSURE TEST PORT ACCESS HOLES ON/OFF/PILOT CONTROL KNOB HI/LO CONTROL KNOB ON/OFF/REMOTE SWITCH PIEZO IGNITOR BURNER TUBE PILOT ASSEMBLY OPERATION INSTRUCTIONS/FLAME APPEARANCE MANUAL VALVE CONTROL KNOB PIEZO IGNITOR BURNER TUBE PILOT ASSEMBLY MANUAL VALVE CONTROL KNOB PIEZO IGNITOR BURNER TUBE PILOT ASSEMBLY Thermostat Valve for VFDT Series Figure 18 Manual Valve for VFDM Series Figure 19 Millivolt Valve for VFDR18LB10 Series Figure 16 VALVE PRESSURE TEST PORT ACCESS HOLES ON/OFF/PILOT CONTROL KNOB ON/OFF/REMOTE SWITCH PIEZO IGNITOR BURNER TUBE PILOT ASSEMBLY Page 16 23099-1-0707 Thermostats are not approved on vented decorative appliances. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 18", 24" and 30" Gas Logs (Millivolt) thermopile is self powered gas valve and does not require 110 volts. See Figure to provide optional wall switch, thermostat, or remote control. Maximum length of 20 feet of 16 AWG to conductor wires is to be used with all optional switches. Check System Operation Millivolt system and all individual components may be checked with a millivolt meter 0-1000 MV range. Remote Receiver Use the following steps to place the remote receiver adjacent to the gas valve. Attention: 1. The remote receiver can not be placed behind the gas valve and burner assembly. 2. When facing the appliance, the remote receiver must be placed to the right of the gas valve and burner assembly. Note: Do not let remote control receiver come in contact with burner assembly. On circulating vent-free firebox, install remote control receiver behind bottom louver. Refer to remote control installation and operating instructions for more details on remote control. 750 Millivolt System When you ignite the pilot, the thermocouple produces millivolts (electrical current) which energizes the magnet in the gas valve. After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON. Allow your pilot flame to operate an additional one (1) to two (2) minutes before you turn the gas control knob from the PILOT position to the ON position. This time period allows the millivolts (electrical current) to buildup to a sufficient level allowing the gas control to operate properly. Millivolt Control The valve regulator controls the burner pressure which should be checked at the pressure test point. Turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point (Use test point “A” closest to control knob). After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks. REMOTE/OFF/ON SWITCH A DISTANCE/FERME/OUVERT INTERRUPTEUR IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH NUMBER 18, 150°C WIRE OR ITS EQUIVALENT. SI UN DES FILS ELECTRIQUES ORIGINAUX, VENANT DU FABRICANT AVEC CETTE UNITE, DOIT ETRE REMPLACE, VOUS DEVEZ LE REMPLACER AVEC UN FIL ELECTRIQUE DE NUMERO 18, 150 ° C DU L'EQUIVALENT. THERMOPILE GAS VALVE THERMOCOUPLE (NATURAL) OFF ON REMOTE (OPTIONAL) REMOTE CONTROL RECEIVER (FACULTATIVE) CONTROLE E DISTANCE DU RECEPTEUR (OPTIONAL) WALL SWITCH INTERRUPTEUR MURAL (FACULTATIVE) (OPTIONAL) THERMOSTAT (FACULATIVE) THERMOSTAT WIRING DIAGRAM GAS VALVE VALVE DE GAZ REMOTE/OFF/ON SWITCH A DISTANCE/OUVERT/ FERME INTERRUPTEUR REMOTE CONTROL RECEIVER/ THERMOSTAT/ CONTROLE E DISTANCE DU RECEPTEUR H N VEILLEUSE PILOT THERMOCOUPLE (LPG) WIRING - VFDR MODELS ONLY Figure 20 23099-1-0707 Page 17 WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavi...
Dieses Handbuch ist für folgende Modelle:Gas Heizthermen - UNVENTED GAS LOG HEATER VFDM18LBN-1 (3.61 mb)
Gas Heizthermen - UNVENTED GAS LOG HEATER VFDM24LBN-1 (3.61 mb)
Gas Heizthermen - UNVENTED GAS LOG HEATER VFDM30LBN-1 (3.61 mb)
Gas Heizthermen - UNVENTED GAS LOG HEATER VFDR18LB10N-1 (3.61 mb)