Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Enerco, modell MH210KT

Hersteller: Enerco
Dateigröße: 433.11 kb
Dateiname:
Unterrichtssprache:
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


When replacing the filter cover, be sure the gasket is firmly in place and the screws in the filter cover are tight to prevent air leaks. 2. FUEL FILTER. Remove the fuel filter from fuel line and direct compressed air through the filter in the opposite direction of fuel flow. Safety glasses should be worn when using compressed air. 3. AIR AND FUEL LINES. If the air or fuel lines are removed during cleaning, be sure all connections are tight before operating unit. 4. AIR PRESSURE SETTING. The air pressure has been properly set at the factory. If the air pressure is out of adjustment, it will most likely be caused by dirty air filters, a partially plugged nozzle, an air leak in the system or improperly set pressure. If adjustment becomes necessary, first determine the proper pressure setting for your heater which is printed on the serial label located on the fuel tank. Remove the plug from the air filter cover and attach an accurate pressure gauge calibrated to a maximum reading of 15 PSI. Start the heater and note the pressure reading. If the pressure is low, slowly turn the pressure adjusting screw in (Clockwise) until the correct pressure is obtained. If the air pressure is high, turn the adjusting screw out (counterclockwise) until the pressure is correct. When correct pressure is reached, unplug the heater, remove the gauge and replace the plug. STORAGE Store the heater in a dry location free from fumes or dust. At the end of each heating season, clean the heater as described in the MAINTENANCE section. Drain and flush the fuel tank with clean fuel. The manufacturer recommends completely filling the tank with fuel for extended storage to minimize condensation inside the tank. SERVICING A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly: * The flame is contained within the heater. * The flame is essentially yellow. * There is no strong disagreeable odor, eye burning or other physical discomfort. * There is no smoke or soot internal or external to the heater. * There are no unplanned or unexplained shut downs of the heater. DIAGNOSTIC FLAME CONTROL: This heater is eqiupped with a diagnostic control board and flashing LED error indicator. This flashing LED signals when there is a Malfunction of a monitored component. See the following diagnostic Guide for error signal and a brief description of the error: LED UNIT OPERATION Show Flash ........ System lockout-High temp limit or rollout ........................... switch open 2 Flashes .......... System lockout-flame exist before motor .......................... starting 4 Flashes ........... System lockout-motor no normal operation 5 Flashes ........... System lockout-RESET KEY error 6 Flashes ........... System lockout-failled to detect flame Steady Off .......... Waiting or normal operation Steady On .......... Ignition control failure Enerco Group, Inc. | Kerosene Forced Air Heater ...

Dieses Handbuch ist für folgende Modelle:
Gas Heizthermen - MH175KT (433.11 kb)
Gas Heizthermen - HS125KT (433.11 kb)
Gas Heizthermen - MH125KT (433.11 kb)
Gas Heizthermen - MH50KT (433.11 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien