Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Modine Manufacturing, modell GAS-FIRED HEATERS PD

Hersteller: Modine Manufacturing
Dateigröße: 3 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Y = FEET TO END OF FLOOR COVERAGE. Z = FEET TO END OF THROW. 30° HOOD 60° HOOD THROW-FLOOR COVERAGE Mounting Height to Bottom of Heater 30° Downward Hood For Propeller Units & & Data Based on units fired at full rated input with an entering air temperature of 60°-80°F. Maximum mounting heights higher versus units without outlet devices. 60° Downward Hood For Propeller Units & 90° Downward Hood For Propeller Units & Heater Parts from ACF Greenhouses BD 50 BD 75 BD 100 BD 125 BD 150 BD 175 BD 200 BD 250 BD 300 BD 350 BD 400 Models S S S S S S S S S S S 8' 29 42 56 61 72 79 70 98 113 121 94 10' 26 38 50 55 65 70 63 88 101 108 84 12' 24 35 46 50 59 64 58 80 92 99 77 14' 22 32 43 46 55 60 53 74 85 91 71 16' 21 30 40 43 51 56 50 70 80 85 67 18' 19 28 38 41 48 53 47 66 75 81 63 20' 27 36 39 46 50 45 62 71 76 60 22' 26 34 37 44 48 42 59 68 73 57 24' 24 33 35 42 45 41 57 65 70 55 26' 31 34 40 44 39 55 63 67 52 28' 30 33 39 42 38 53 60 65 50 30' 29 32 37 41 36 51 58 62 49 32' 31 36 39 35 49 56 60 47 34' 35 38 34 48 55 59 46 36' 46 53 57 45 38' 45 52 55 43 40' 44 50 54 42 42' 43 49 53 41 BD 50 BD 75 BD 100 BD 125 BD 150 BD 175 BD 200 BD 250 BD 300 BD 350 BD 400 Models X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 8' 0 31 42 0 40 55 0 50 68 0 50 69 0 56 77 0 60 82 0 53 73 0 68 93 0 74 102 0 78 107 0 66 90 10' 0 28 39 0 38 52 0 48 66 0 49 67 0 55 76 0 59 81 0 52 71 0 67 91 0 74 101 0 77 106 0 65 88 12' 0 25 34 0 36 49 0 47 64 0 47 65 0 54 74 0 57 79 0 50 69 0 65 90 0 72 99 0 76 104 0 63 87 14' 0 19 27 0 33 45 0 44 61 0 45 62 0 52 71 0 56 76 0 48 67 0 64 88 0 71 97 0 75 102 0 62 85 16' 0 11 16 0 29 40 0 42 57 0 42 58 0 50 68 0 54 74 0 46 63 0 62 85 0 69 95 0 73 100 0 60 82 18' 0 22 31 0 38 53 0 39 53 0 47 64 0 51 70 0 43 59 0 60 82 0 68 93 0 72 98 0 58 79 20' 0 33 46 0 34 47 0 43 60 0 48 66 0 39 54 0 58 79 0 65 90 0 70 95 0 55 76 22' 0 26 36 0 27 38 0 39 54 0 44 61 0 34 47 0 55 75 0 63 86 0 67 92 0 52 72 24' 0 16 24 0 33 45 0 39 54 0 24 34 0 51 70 0 60 82 0 64 89 0 48 66 26' 0 46 64 0 56 78 0 61 84 0 43 60 28' 0 40 56 0 52 72 0 57 79 0 36 50 30' 0 30 43 0 46 65 0 53 73 0 22 31 BD 50 BD 75 BD 100 BD 125 BD 150 BD 175 BD 200 BD 250 BD 300 BD 350 BD 400 Models X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 8' 13 29 40 18 38 52 22 47 64 23 47 64 26 53 72 28 56 76 24 50 68 31 63 86 35 69 94 37 73 99 30 61 84 10' 12 28 38 16 37 50 21 46 63 21 46 63 25 52 71 26 55 75 23 49 67 30 62 85 34 69 94 36 72 98 29 61 83 12' 10 25 35 15 35 48 20 45 61 20 45 62 23 51 70 25 54 74 22 48 66 29 62 84 33 68 93 34 71 97 28 60 82 14' 8 21 30 14 33 46 19 43 59 19 43 60 22 50 68 24 53 73 21 47 64 28 61 83 31 67 92 33 71 96 27 59 80 16' 12 30 42 17 41 57 17 42 57 21 48 66 23 52 71 19 45 62 27 59 81 30 66 90 32 69 95 26 57 79 18' 9 25 36 16 39 54 16 39 54 19 46 64 21 50 69 18 43 59 25 58 80 29 65 89 31 68 93 24 56 77 20' 14 35 50 14 36 50 18 44 61 20 48 66 16 40 56 24 56 77 28 63 87 30 67 92 23 54 75 22' 11 30 43 11 31 44 16 41 57 18 45 63 14 36 51 22 54 75 26 62 85 28 65 90 21 52 72 24' 13 36 51 16 42 59 10 29 42 21 52 72 25 59 82 27 63 87 20 49 69 26' 19 48 68 23 57 79 25 61 85 18 46 64 28' 16 44 62 21 54 75 23 58 81 15 41 58 30' 12 36 52 19 50 70 21 55 77 10 32 47 Mounting Height to Bottom of Heater Mounting Height to Bottom of Heater Mounting Height to Bottom of Heater 17 PERFORMANCE DATA – HOODS FOR BLOWER MODELS 90° HOOD 60° Downward Hood For Blower Units ! 90° Downward Hood For Blower Units ! ! Data Based on unit fired at full rated input, 60°-80°F entering air temperature, and a 40°F temperature rise through unit. Maximum mounting heights higher versus units without outlet devises. Performance Data — 30°, 60° and 90° Downward Deflector Hoods 30° Downward Hood For Blower Units ! H S S Heater Parts from ACF Greenhouses 0.0 Static Air Pressure 0.1 Static Air Pressure 0.2 Static Air Pressure 0.3 Static Air Pressure Temp Sheave Sheave Sheave Sheave Model Rise Airflow RPM HP Drive Turns RPM HP Drive Turns RPM HP Drive Turns RPM HP Drive Turns No. (°F) (cfm) No. Open No. Open No. Open No. Open BD 50 BD 75 BD 100 BD 125 BD 150 BD 175 BD 200 BD 250 BD 300 BD 350 BD 400 40 926 720 1/4 C183 2 800 1/3 C1 5 875 1/2 C61 4.5 945 1/2 C61 3.5 45 823 640 1/4 C183 3.5 730 1/4 C183 2 810 1/3 C1 5 885 1/3 C1 4 50 741 575 1/4 C182 1 675 1/4 C183 3 760 1/4 C183 1.5 845 1/3 C1 4.5 55 673 525 1/4 C182 2.5 630 1/4 C182 0 725 1/4 C183 2 810 1/4 C183 0.5 60 617 480 1/4 3.5 595 1/4 C182 0.5 695 1/4 C183 2.5 785 1/4 C183 1 65 570 445 1/4 C182 4.5 565 1/4 C182 1.5 670 1/4 C183 3 760 1/4 C183 1.5 70 529 410 1/4 C182 5 545 1/4 C182 2 650 1/4 C183 3 745 1/4 C183 1.5 40 1389 585 1/2 C186 2.5 670 1/2 C186 1.0 745 3/4 C187 3.5 820 3/4 C187 2.5 45 1235 520 1/3 C185 4 615 1/2 C186 2.0 700 1/2 C186 0.5 775 1/2 C187 3.5 50 1111 470 1/4 C184 1 575 1/3 C185 3.0 665 1/3 C185 1.0 745 1/2 C187 3.5 55 1010 425 1/4 C184 2 540 1/4 C185 3.5 635 1/3 C185 1.5 725 1/2 C186 0.0 60 926 390 1/4 C184 3 510 1/4 C185 4.0 615 1/4 C185 2.0 705 1/3 C185 0.0 65 855...

Dieses Handbuch ist für folgende Modelle:
Gas Heizthermen - GAS-FIRED HEATERS BD (3 mb)
Gas Heizthermen - GAS-FIRED HEATERS BD (3 mb)
Gas Heizthermen - GAS-FIRED HEATERS BD (3 mb)
Gas Heizthermen - GAS-FIRED HEATERS BD (3 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien