Hersteller: Desa
Dateigröße: 632.41 kb
Dateiname: 7a163d3c-2725-6cd4-4d96-09946c854099.pdf
|
Anleitung Zusammenfassung
CAUTION: This appliance is hot during normal operation, avoid physical contact. CAUTION: Do not place clothing or other combustible materials on this appliance. DO NOT operate this heater if any part has been under water. Call a qualified service technician to inspect the appliance and to replace any part of the control system or gas control valve which has been under water. LIGHTING HEATER 1. Before attempting to light the heater, smell all around the heater area for gas. Turn on the gas supply to the appliance and check all fittings and connections for gas leaks using a mild soap and water solution. NEVER use a match to check for gas leaks. Should a gas leak occur, shut off the gas supply to the appliance immediately. Wait a minimum of five minutes before repairing the leak. 2. Use only the fuel intended for this appliance. Check the appliance rating plate for the correct fuel information. 3. Turn the control knob clockwise to the OFF position. See Figure 1, page 3 and Figure 2 for location of appliance parts. 4. Wait a sufficient length of time (at least five minutes) to allow gas which may have accumulated in burner compartment to escape. 5. Turn on the main gas supply. 6. Turn control knob counterclockwise to the PILOT position. 7a. Press and turn control knob counterclockwise to PILOT position and hold for 1 to 2 minutes. This may take longer to purge air from supply hose depending on length of the hose being used. Press red spark ignition button to light pilot flame (repeat until pilot lights) and continue to hold control knob at PILOT position for 30-60 seconds to enable pilot light safety system. Fully turn control knob to HI position to light burner. 7b. To match light the pilot, move the lighting hole cover aside (see Figure 2) and place a lighted match into hole. Press control knob and hold while lighting and observing pilot burner. Ensure that pilot burner ignites from match. Allow pilot to burn approximately 30 seconds before releasing control knob. If pilot does not remain lit, repeat lighting operation allowing a longer period of time before releasing control knob. Note: In cases where long runs of gas supply lines have been installed ahead of the appliance, it may be necessary to bleed trapped air out of supply lines before lighting pilot. New installations generally require bleed of supply lines. Wait a minimum of five minutes after bleeding supply lines before attempting to light heater. Adjust pilot if necessary as noted under Pilot Burner Adjustment, page 7. 8. Turn control knob counterclockwise to the ON position. The burner will light. DO NOT operate heater in any position other than full ON. IMPORTANT: DO NOT attempt to adjust the main burner input using the main gas supply valve. This may cause the pilot and thermocouple to shut down the burner. Combustion Chamber Thermocouple Burner Mounting Brace Match Lighting Hole Cover Pilot Assembly Filter Gas Manifold Control knob Figure 2 - Appliance Parts Identification 114248-01A OPERATING INSTRUCTIONS Continued SHUTTING OFF HEATER • For short periods of time, turn the main burner off by turning control knob clockwise to the PILOT position. • For extended periods of non use, turn appliance completely off by turning control knob clockwise to the PILOT position, press knob slightly, then turn knob fully clockwise to the OFF position. Note: For propane/LP gas models, also turn off gas supply cylinder.) PILOT BURNER ADJUSTMENT 1. Remove pilot adjustment cap. The pilot adjustment cap is a slotted screw located in front of the PILOT designation stamped on top of valve body just below control knob. 2. Adjust pilot key to provide properly sized flame. Rotate the key clockwise to decrease flame or counterclockwise to increase flame. 3. Replace pilot adjustment cap. MAINTENANCE WARNING: • Never attempt to service heater while it is connected to propane supply, operating or hot. Severe burns can occur. • Keep heater clear and free from combustible materials, gasoline and other flammable vapors and liquids. • Do not block the flow of combustion or ventilation air. 1. Keep heater clean. Clean heater annually or as needed to remove dust and debris. If heater is dirty or dusty, clean heater with a damp cloth. Use household cleaners on difficult spots. 2. Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak. Correct all leaks at once. 3. Inspect hose/regulator assembly before each use. If hose is highly worn or cut, replace. 4. Have heater inspected yearly by a qualified service agency. SPECIFICATIONS Propane/LP Model 125-R Rating 125,000 Btu/Hr (131,882 kj) Fuel Propane Vapor Only Fuel Consumption per Hour 5.17 liters (1.3 gallon) 2.6 kg (5.8 pounds) Supply Pressure To Regulator (for input adjustment) Maximum 1380 kPa (200 psi) Minimum 138 kPa (20 psi) Manifold Pressure 2.3 kPa (9.5 inches W.C.) Weight Heater 17.69 kg (39 lbs) Shipping 20.86 kg (46...